Excercise 4 - Jakub Możaryn
Institute of Automatic Control and Robotics Faculty of Mechatronics Automation Systems laboratory Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Autors : PhD. Eng. Danuta Holejko, PhD. Eng. Jakub Możaryn, MSc. Eng. Kacper Malinowski, BSc. Eng. Michał Bezler Warsaw, 2016 Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Identification of process in control system of level in tank with free outflow of liquid The aim of the exercise is to determine a mathematical model of the process of the changes in the liquid level in the open tank, on the basis of experimentally determined static and dynamic characteristics,. The process of obtaining a mathematical model is called the identification of the object. 2. DESCRIPTION OF THE PROCESS INSTALATION Experiments were conducted on laboratory stand presented in Fig. 1. Controlled process is a change of liquid level in connected tanks Z1, Z2. Fig.5 presents installation diagram. Depending on the configuration \of the valves V2 and V4 and the use of specially constructed elastic tube there can be realized process with various properties (see Table 1). Table 1. Properties of the process depending on the valves configuration. No. 1. 2. 3. 4. Type of the process 1st order lag system without delay 1st order lag system with delay 2nd order lag system without delay 2nd order lag system with delay Valve Valve setup V2 Closed V4 Liquid flows directly into tank Z1 V2 Closed V4 Liquid flows into tank Z1 through elastic tube W V2 Open V4 Liquid flows directly into tank Z1 V2 Open V4 Liquid flows into tank Z1 through elastic tube W Process value Level H1 Level H1 Level H2 2 Automation Systems Level H2 Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Figure 1. Installation scheme of the laboratory stand for designing the control system of the liquid level in a tank. Description : Z1, Z2 – tanks, V1, V3 - manual outflow valves V2 - manual valve connecting tanks Z1 and Z2, V4 - threeway valve , W- elastic tube, T0 - transport delay introduced by elastic tube, VE1- electromagnetic valve to cut-off the outflow from tank Z1. VE2 - electromagnetic valve to cutt-off the water outflow at the pump plunging. H1 , H2 - height of the liquid column in tank Z1, Z2, PV – output signal from the liquid level sensor, LT1, LT2 – liquid level sensors in tanks Z1, Z2, Q - output signal from the flow sensor QT (Venturi flowmeter), P- variable displacement pump, CV - pump control signal (output signal from PLC controller), P1, P2 - manual switches of electromagnetic valves to introduce disturbances. 3 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Components of the stand (Fig. 1) are: tanks Z1 and Z2, a pump P is controlled by standard current signal that corresponds to a change of the pump capacity 0 - 6.5 [l / min], LT1, LT2 are pressure transducers (measuring range 0-500 mmH20) for measuring a liquid level in each of tanks (H1, H2), W is elastic tube, through which the liquid can flow into the tank Z1 (it introduces the transport delay to the object). V 1, V2, V3, V4 are manually operated valves, which are used to change the way that liquid flows. There are also two electromechanical valves (VE1, VE2), used to introduce disturbances into the process. By ZK1 we denote leakage from the tank Z1 (opening the valve VE1), and by ZK2 we denote leakage at pump outlet (opening the valve VE2). Connection of the tanks is realized by using of shut-off valve V2. The controlled variable is the height of the column of liquid in the tank Z1 (H1) or tank Z2 (H2). Requirement for a system is to regulate it to keep at a preset constant value the height of water column despite the disturbances acting on the object. Disturbances are changes of the flow at the inlet or outlet of the tanks. These disturbances are carried out by remote-controlled shut-off magnetoelectric valves VE1, VE2. Opening / closinf of valves is realized using the P1 and P2 buttons located on the desktop stand. The valve VE1 induces a step change in flow at the outlet from the tank Z1. It is the fault VE1. The valve VE2 induces a step change in flow at the inlet to the tank Z1 (ie. liquid drop from the pump). It is the fault VE2. The control value of the object is a standard signal 4 - 20 mA from the controller Simatic PLC S7-1200 (Siemens). This signal is converted by a electronic circuit to the voltage signal 0 - 10 V and operate the pump, the output of which varies in the range: 0 - 6.5 l / min at the inlet to the tank Z1. This pump acts as an actuator in the control system. In addition, a flow measurement is carried out using a Venturi flowmeter. The flow changes from 0 to 6.5 L / min causes a pressure difference across the Venturi flowmeter in the range from 0 to 500 mm H2O. Applied differential pressure transducer converts the pressure difference across the orifice to a standard signal range of 4 - 20 mA. Information on the current value of the controlled variable (height H1 or H2 of the liquid column) is provided by electrical transducers with the range of 0 - 500 mm H2O and the output signal 4 - 20 mA (measuring the height of the liquid column is carried out using the indirect method by measuring hydrostatic pressure). 4 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” 3.Course of exercise Identification of the described process will be conducted in the control system presented in the scheme at Fig.6. Identification of the process will be conducted on the basis of the measurement of the static characteristics in the full range of possible changes in the controlled variable and the time response of the process to introduced step input signal for a chosen operationg point selected from static characteristic. This will be therefore an experiment in which intentional impact on the process will take place through the control signal set by the operator. Measurements of static and dynamic properties of the object will be carried out in a fixed set point open control system of liquid level (in manual mode). Static and dynamic properties would be represented by the relationship between the controlled variable, which is the height H1 of the liquid column in the tank Z1 processed to a measured signal PV, the control signal CV and between the controlled variable and the introduced disturbances. These compounds will be represented by the transfer function of a process Gob (s) and the transfer functions of disturbances GZ1 (s), GZ2 (s). These transfer functions will represent the dynamic properties od the system in the vicinity of the operating point of the process. 5 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Figure 6. Electrical scheme of the control system of the liquid level in a tank. The laboratory stand include: tanks connected in series, SIMATIC S7-1200 PLC (Programmable Logic Controller) with the analog inputs / outputs modul and power supply 24V, HMI display with a color touch screen, desktop PC with TIA Portal software. 6 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” 3.1.Visualization During the exercise the student communicates with the PLC via the operator diplay (SIMATIC HMI KPT600). On the Home screen, select an object tank (Zbiornik) and the single close-loop structure of a control system (Jednoobwodowy). After pressing the "Start" button, user god to the object visualization pressing the buttom "Tank" (Zbiornik). Figure 7. Visualisation of the stand In the next step user should go to the screen with object identification (button "Identyfikacja obiektu", Fig. 8). Figure 8. Screen for identification of a process. 7 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” From this screen ("Identyfikacja obiektu", Fig. 8), it is possible to set (in percents) control signals on both analog outputs (in this proscess do not use analog output 1). Visualisation, in the form of plots the changes of the input and output values, is carried out on a PC using software TIA PORTAL. The home screen of this visualisation is shown in Fig. 9. Figure 9. Start screen in TIA Portal simulation. The start screen (Fig. 9) contains information about the entered structure. When pressing "Regulator główny" button, user will be send to the screen with monitoring of the input and output variables (Fig. 10). 8 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Figure 10. Screen with monitoring of the input and output variables Over plots there is a graph showing the active disturbances in the form of a bar chart: Red rolor - valve VE1, Orange color - valve VE2, Green color - "SP step function". 1. Start / Stop button allow user to stop or resume monitoring of the input / output values. 2. The „Zwiększ przedział czasu” ("Increase the time interval") and ("Decrease time interval") buttons allow user to modify the currently displayed time interval ranging from 15sec to 16min 3. The fields below the text „Oś” ("Axis") allow scaling of the Y-axis of the graph. Increasing the scope is performed immediately. In the case of reducing the scope of the scale the changes will be visible after some time. 4. . The "skok SP" ("SP step") button allows user to generate the step function of a setpoint, together with the monitoring of it in the upper graph. 5. The text next to the "Cofnij" ("Undo") button allows user to enter the value of the SP later activated the "Skok SP" ("SP step") button. After entering any of the values, do not change the value of this field before resetting the value by pressing "Cofnij" (""Undo") button. 6. The "Cofnij" ("Undo") button resets the step function activated by "skok SP" ("SP step") button. 9 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” To print the chart, the course of the changing values should be stopped by START / STOP button, the user should press the button on a computer keyboard PrtSc and then paste saved screen into graphical editor. 3.2. Identyfikacja eksperymentalna właściwości statycznych obiektu regulacji Identyfikacja właściwości statycznych obiektu sprowadzać się będzie do pomiaru charakterystyk statycznych obiektu jako związku w stanie ustalonym wielkości regulowanej od sterowania w pełnym zakresie działających zakłóceń. Charakterystyki te są istotne do określenia możliwych punktów pracy obiektu i dopuszczalnych sterowań. Charakterystyki statyczne wykonywane będą dla trzech oddzielnych przypadków: 1. Zawory VE1 i VE2 zamknięte => brak zakłóceń 2. Zawór VE1 – otwarty, VE2 – zamknięty => zakłócenie VE1 3. Zawór VE1 – zamknięty , VE2 – otwarty => zakłócenie VE2. Wyniki pomiarów należy zamieścić w odpowiednich komórkach tablicy 2. Każdy z tych przypadków wymaga przeprowadzenia takiej samej procedury, którą przedstawiono poniżej: a) Sprawdzić położenie zaworów VE1 i VE2 poprzez skontrolowanie stanu przełączników P1 i P2, bądź lampek kontrolnych na wizualizacji komputerowej. b) Ustawić na panelu HMI sygnał sterujący pompą CV na wartość 0% c) Odczytać i zapisać bieżącą wartość PV poziomu wody. d) Odczytać poziom wody H1 wykorzystując skalę umieszczoną na ściance zbiornika. e) Wykonać punkty od c) do e) zmieniając wartość sygnału sterującego pompą CV zgodnie z tablicą 2. Procedurę powtórzyć dla kolejnych dwóch przypadków. .Wyniki pomiarów zamieścić w tablicy 2. Tablica 2. Wyniki pomiarów charakterystyki statycznej obiektu regulacji 0 20 30 40 50 60 70 80 CV[%] H1[cm] 1. PV[%] H1[cm] 2. PV[%] H1[cm] 3. PV[%] 10 Automation Systems 100 Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” 3.3. Identyfikacja właściwości dynamicznych obiektu regulacji Celem identyfikacji będzie określenie parametrów transmitancji zastępczych: obiektu i zakłóceniowych. Identyfikacja ta zostanie przeprowadzona metodą eksperymentu czynnego w którym wykorzystano metodę odpowiedzi skokowej generując skokowe zmiany sygnału sterującego CV i wielkości zakłócających. Metoda ta pozwala na wyznaczenie parametrów założonej transmitancji obiektu na podstawie prostych konstrukcji graficznych. Z otrzymanych z badań odpowiedzi obiektu na zakłócenia skokowe określać się będzie transmitancje operatorową obiektu względem sterowania Gob.(s) , oraz transmitancje operatorowe obiektu G z1.(s), G z2.(s) względem zakłóceń . 3.3.1.Wyznaczenie odpowiedzi skokowej obiektu regulacji na zmianę sterowania CV (zwiększenie wydajności pompy) w układzie otwartym. Określenie parametrów transmitancji Gob(s) Badania przeprowadzić stosując poniższą procedurę: a) Sprawdzić, czy zawory VE1 i VE2 są zamknięte b) Na panelu HMI ustawić CV=50% c) Odczekać aż PV osiągnie ustaloną wartość d) Zmienić wartość CV z 50% na 60% e) Odczekać aż poziom wody się ustali, tzn. PV ≈ const f) Zapisać cały przebieg przejściowy na komputerze dobierając odpowiedni przedział czasu. Zaleca się przyjąć ok. 300 sek. g) Po zatrzymaniu przebiegu na monitorze przyciskiem STOP, wcisnąć na klawiaturze komputera przycisk prtsc ,wkleić zapamiętany ekran do edytora graficznego i wydrukować dwie kopie przebiegu przejściowego ( do obróbki wykresu stosując metodę stycznej (rys.9) i siecznej rys.4). Figure 9. Przykład konstrukcji graficznej do określania parametrów transmitancji operatorowej obiektu wyznaczonych metodą stycznej Otrzymany przebieg będzie miał postać jak na rys.9 Zgodnie z rys.9, dla badanego obiektu można przyjąć model matematyczny opisany transmitancją (2) : 11 Automation Systems Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” Gob (s ) PV (s ) k ob e T0s CV (s ) Tz s 1 (6) Z zarejestrowanego przebiegu należy odczytać wartości parametrów zastępczej transmitancji operatorowej obiektu :Tz ,T0, kob. Parametry te należy odczytać stosując metodę stycznej (rys.9) oraz metodę siecznej (rys.4). Przedstawione transmitancje zostaną zastosowane do doboru nastaw regulatora w układzie regulacji poziomu cieczy w zbiorniku. 3.3.2. Wyznaczenie odpowiedzi skokowej obiektu dla zakłócenia wywołanego zwiększeniem odpływu cieczy (skokowa zmiana otwarcia zaworu VE1). Określenie parametrów transmitancji zakłóceniowej G z1(s) Wykonać następujące czynności: a) Sprawdzić, czy zawory VE1 i VE2 są zamknięte b) Na panelu HMI ustawić CV=50% c) Odczekać aż poziom wody się ustali, tzn. PV ≈ const. d) Przełącznikiem P1 (rys.6) wprowadzić zakłócenie VE1 e) Poczekać na ustalenie się poziomu f) Zapisać cały przebieg przejściowy, który posłuży do wyznaczenia parametrów założonej transmitancji: PV (s ) k (7) 1 e T0s f (s ) T1s1 f- zmiana powierzchni przepływowej zaworu VE1. Wg danych katalogowych f = 30.4 % PV Na zarejestrowanym wykresie odczytać PV i obliczyć w ten sposób wartość k1 f G z1(s ) 3.3.3. Wyznaczenie odpowiedzi skokowej obiektu wywołanej zmianą otwarcia zaworu VE2 („zrzut” z pompy). Określenie parametrów transmitancji zakłóceniowej Gz2(s) a) b) c) d) e) f) Należy wykonać następujące czynności: Sprawdzić, czy zawory VE1 i VE2 są zamknięte Na panelu HMI ustawić CV=50% Odczekać aż poziom wody się ustali, tzn. PV ≈ const Przełącznikiem P2 (rys.5) wprowadzić zakłócenie VE2 Poczekać na ustalenie się poziomu Zapisać cały przebieg przejściowy, który posłuży do wyznaczenia transmitancji: Gz 2 (s ) k2 PV (s ) e T0 s f (s ) T2 s 1 12 Automation Systems (8) Excercise 4 „Identification of process in control system of level in tank with free outflow of liquid” f- zmiana powierzchni przepływowej zaworu VE1, wg danych katalogowych f = 30.4 %. Z zarejestrowanego wykresu odczytać PV i obliczyć podobnie jak w p.3.3.2 wartość k2. 4. SPRAWOZDANIE Z ĆWICZENIA Sprawozdanie winno zawierać takie elementy jak: opis przebiegu ćwiczenia , schematy, wykresy otrzymane z rejestratora z naniesioną obróbką danych, wykresy wykonane na podstawie pomiarów itp. oraz odpowiedzi na pytania poniżej: 1) Określ parametry transmitancji obiektu stosując metodę siecznej oraz stycznej. 2) Określ przebieg odpowiedzi skokowej obiektu obliczony na podstawie przyjętych transmitancji i dokonaj porównania z przebiegiem rzeczywistym. 3) Narysuj schemat blokowy badanego obiektu regulacji oraz przeprowadź jego analizę. 4) Narysuj charakterystykę statyczną obiektu i przeprowadź analizę właściwości statycznych obiektu, 5) Określ na podstawie charakterystyki statycznej obiektu możliwe punkty pracy układu regulacji 6) Porównaj wartość wzmocnienia obiektu kob otrzymaną z charakterystyki statycznej obiektu oraz z charakterystyki skokowej. Skomentuj otrzymane wyniki. 7) Określ na podstawie schematu blokowego obiektu jaki winien być kierunek działania regulatora w układzie zamkniętym. 5. LITERATURA 1.Kościelny W.J.: Materiały pomocnicze do nauczania podstaw automatyki dla studiów wieczorowych, WPW, 1997, 2001. 2. Węgrzyn S.: Podstawy automatyki. PWN 1980 3. Żelazny M.: Podstawy automatyki . PWN, 1976 13 Automation Systems