Schischek - AP Automatyka
Transkrypt
Schischek - AP Automatyka
Schischek Explosionproof. Protection of Life. Health. Assets. Technical Short information 2012 2 0 1 4 Price list –short Technical valid from information 1. January 2014 2014 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Schischek Global Coverage Greenland Sweden Iceland Finland R u s s i a Norway Estonia C a n a d a United Kingdom Latvia Denmark Lithuania Neth. Ireland Bel. France Czech Rep. Licht. Switz. Austria Italy Ukraine Slovakia Albania Mace. Bulgaria Uzbekistan Georgia Armenia Azerb. Greece Turkmenistan Turkey Tunisia Kyrgyzstan N. Korea Tajikistan Syria Cyprus Lebanon Israel Malta Morocco Mongolia Romania Bos. & Serb. Herz. Mont. Gibraltar Kazakhstan Mold. Hungary Slovenia Croatia Spain Portugal United States Belarus Poland Germany Lux. C Iraq Iran Saudi Kuwait Bahrain Qatar Arabia U.A.E. h i n S. Korea a Japan Afghanistan Jordan Algeria Bahamas Mexico Cuba Belize Guatemala El Salvador Mauritania Haiti Cape Verde Trinidad & Tobago Panama Venezuela Guyana French Guiana Colombia Senegal Gambia Guinea-Bissau Nicaragua Costa Rica Egypt (Occupied by Morocco) Dom. Rep. Puerto Rico Jamaica Honduras Libya Western Sahara Suriname Guinea Sierra Leone Liberia Mali Burkina Faso Benin Cote Togo d'Ivoire Ghana Chad Eritrea Sudan 2 Cambodia Cameroon Central African Republic Sri Lanka Somalia Uganda Congo Dem. Rep. of Congo Hong Kong Taiwan Philippines Vietnam Palau Brunei Malaysia Singapore Kenya Rwanda Burundi I n d o n e s i a Tanzania B r a z i l Zambia Bolivia Namibia Paraguay Papua New Guinea Solomon Islands East Timor Angola Chile Laos Thailand Ethiopia Peru Headquarter/ Manufacturing Schischek GmbH Mühlsteig 45 Gewerbegebiet Süd 5 90579 Langenzenn Germany Tel. +49 9101 9081- 0 Fax +49 9101 9081-77 [email protected] www.schischek.com Bangladesh India Yemen Dijbouti Nigeria Gabon Bhutan Oman Niger Equatorial Guinea Ecuador Nepal Pakistan Somoa Malawi Vanuatu Fiji Zimbabwe Mauritius Mozambique Tonga Botswana Swaziland Lesotho Madagascar A u s t r a l i a South Africa Argentina Uruguay New Zealand Schischek GmbH – Langenzenn / Germany Rotork - Schischek Sales Schischek contact worldwide: www.schischek.com/contact/schischek-worldwide www.rotork.com/en/contact/index/ www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Safety, worldwide, in thousands of applications! Explosion protection since 1975 Safety is essential Since 1975 Schischek has supplied electric explosion proof products worldwide for heating, ventilation and air-conditioning, for industrial and offshore applications. With this motto we state that explosion protection is not a question of statistics or half hearted solutions but that 100% safety must be guaranteed at all times. Explosion protection means taking on responsibility. Schischek Explosionproof has become an important partner for consultants, public authorities, control companies, installers, OEM‘s and, not least of all, the end user. As supplier of components, we have always considered it our duty to develop products in conjunction with other control equipment. Modern Ex equipment, reliable, proven and with “state of the art” technology. “There is no little ex-protection!” People have confidence in us as Ex protection specialists and in you as consultant, installer and contractor. All Schischek Ex products are, therefore, PTB certified, approved by and produced according to the very latest standards and regulations. According to type and kind of protection, our products are suitable for operation in Ex areas, zones 0, 1, 2, 20, 21 and 22, including gases, vapours, mists and dusts – of course in accordance with ATEX 94/9/EC. Heating, Ventilation, Air-Conditioning Schischek supplies control companies and contractors in the Building Automation market. We have developed equipment which is compatible with nearly all control systems. By combining Schischek products with conventional switching and control equipment, reliable high quality systems are implemented that conform to Ex protection standards. Some examples of use are fire and smoke dampers, paintspray areas, exhaust systems in chemical laboratories, battery rooms, sewage treatment plants, pumping stations etc. Harsh environmental conditions and robust quality cause stringent design / construction requirements on components and materials. A fast closing electric actuator for fire / smoke dampers of less than 3 seconds is a requirement on oil and gas platforms as well as on FPSO‘s. After an intense development process including trials, a completely new concept in actuator engineering was produced. Since, thousands of Schischek actuators in special aluminium, C5-M and stainless steel housings have been delivered and installed, moreover, the product range has been continuously enlarged and refined. Whether you need air flow control in a pharmaceutical plant or temperature regulation of paint tanks in the car industry, Schischek offers cost-effective solutions specifically designed for control integration. Ex protection is required for applications from paint spray shops to drying stations. System compatibility with all aspects of control facilitates integrated planning from design to completion. At the same time, safety and reliability increase in planning, installation, approval and operation. Since all equipment is maintenance-free, cost savings are realised. In co-operation with valve and damper manufacturers, industrial control companies and contractors, Schischek products are in use worldwide. Our products are characterised by the “highest protection class, compact size and easy handling”. We can provide solutions to problems as far as Ex ventilation and precise temperature control in industrial plants are concerned. Offshore, Onshore, Shipbuilding Chemical, Pharmaceutical, Car Industries Water Treatment Plants, Compressor Stations www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 3 Price list 2014 Technical short info 2014 Which components have to be explosion proof ? I n the diagram below, a typical air-handling system shows which equipment is allowed in the Ex area and which should only be placed in the safe area. The diagram does not claim to be complete. Air damper Air filter I f in doubt, please do not hesitate to consult us at Schischek. We will advise you in any case. A brief discussion in the early stages of planning can avoid substantial costs in remedial work later and gives you the peace of mind that you have a safely installed operating system. Heater Fan Humidifier + M Ex area M rP 1 6 3 F rP 7 6 2 M Safe area M %rH rF Hz 1 2 Quarter turn actuators for dampers and valves ExMax RedMax 4 Failsafe linear valve actuators ExMax + LIN RedMax + LIN «1P VHF On-off, 3-pos modulating with/without spring return 3 «1 «PPVWURNH 0,1...15 sec /mm On-off, 3-pos modulating with spring return 4 Linear valve actuators ExRun RedRun «1 «PPVWURNH 2...15 sec /mm On-off, 3-pos modulating Temperature and humidity sensors ExCos-D RedCos-D í&«& «U+ full range adjustable www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Y ou should be aware of the areas of installation where an explosive atmosphere may build up. Furthermore, you should have the responsible authority classify the relevant Ex zone and in combination with type and condition of the explosive medium, you should be able to select suitable explosion proof equipment. Restrictor %rH rF 4 7 5 ith Schischek products this is simple because all equipment is certified according to the highest safety standards – according to ATEX, of course! Restrictor Air damper Fire damper rP M M °C rP °C W 8 8 °C PLC-System 5 PLC-System Filter monitoring, fan belt protection ExCos-P RedCos-P ExBin-P RedBin-P «3D full range adjustable «3D Pressure/Differential pressure Fan-belt protection Filter protection 1- or 2-stage switching point 1 VAV 6 Pressure/ differential pressure sensors 1 7 Thermostats, humidistats, Frost protection 8 Controller ExBin-D RedBin-D í&«& «U+ 1- or 2-stage ExReg-V Differential pressure «3D9$9 ExBin-FR RedBin-FR í&«& &DSLOODU\PP 1-stage switching point ExReg-D Temperature/Humidity í&«& «U+ www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 5 Price list 2014 Technical short info 2014 Table of contents Product series Quarter turn actuators 90° 2YHUYLHZ HOHFWULFDODFWXDWRUVZLWKDQJOHRIURWDWLRQ ([0D[ VL]H6 « 1P ZLWKZLWKRXWVSULQJUHWXUQ ([0D[ VL]H0 « 1P ZLWKZLWKRXWVSULQJUHWXUQ 5HG0D[ VL]H6 « 1P ZLWKZLWKRXWVSULQJUHWXUQ 5HG0D[ VL]H0 « 1P ZLWKZLWKRXWVSULQJUHWXUQ ,Q0D[ VL]H6 « 1P ZLWKZLWKRXWVSULQJUHWXUQQRW([ ,Q0D[ VL]H0 « 1P ZLWKZLWKRXWVSULQJUHWXUQQRW([ Linear valve actuators with spring return with 7,5/ 10/ 15/ 20/ 30/ 42 mm stroke (fixed) 2YHUYLHZ HOHFWULFDOOLQHDUDFWXDWRUV /,1 ([0D[ VL]H60 « 1 ZLWKVSULQJUHWXUQ /,1 5HG0D[VL]H60 « 1 ZLWKVSULQJUHWXUQ /,1 ,Q0D[ VL]H60 « 1 ZLWKVSULQJUHWXUQQRW([ Valve actuators with 5...60 mm stroke ([5XQ VL]H6 « 1 ZLWKRXWVSULQJUHWXUQ 5HG5XQ VL]H6 « 1 ZLWKRXWVSULQJUHWXUQ ,Q5XQ VL]H6 « 1 ZLWKRXWVSULQJUHWXUQQRW([ Special options for actuators Overview special options for actuators Overview heating system ExPolar for actuators ([3RODU KHDWLQJV\VWHPIRUDFWXDWRUVXVHLQ([DUHDVGRZQWRí& ,Q3RODU KHDWLQJV\VWHPIRUDFWXDWRUVXVHLQVDIHDUHDGRZQWRí&QRW([ Controller for VAV, pressure, temperature, humidity 2YHUYLHZ FRQWUROV\VWHP ([5HJ9 YROXPHIORZDQGSUHVVXUHFRQWUROOHU « 3D ,Q5HJ9 YROXPHIORZDQGSUHVVXUHFRQWUROOHU « 3DQRW([ ([5HJ' WHPSHUDWXUHDQGKXPLGLW\FRQWUROOHU í«& «U+ ,Q5HJ' WHPSHUDWXUHDQGKXPLGLW\FRQWUROOHU í«& «U+QRW([ Modulating sensors for temperature, humidity, pressure/ differential pressure Overview modulating sensors ([&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3D 5HG&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3D ,Q&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3DQRW([ ([&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU([3UR&«VHQVRUV 5HG&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU([3UR&«VHQVRUV ,Q&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU,Q3UR&«VHQVRUVQRW([ ([3UR&« WHPSHUDWXUHDQGKXPLGLW\VHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPV ,Q3UR&« WHPSHUDWXUHDQGKXPLGLW\VHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPVQRW([ ExCos-A transducer for passive, potential free, modulating ExSens sensors RedCos-A transducer for passive, potential free, modulating ExSens sensors ,Q&RV$ WUDQVGXFHUIRUSDVVLYHSRWHQWLDOIUHHPRGXODWLQJVHQVRUVQRW([ ExLine transducer EXL-IMU-1 for passive, potential free, modulating ExSens sensors ExSens modulating, passive temperature- /humidity- /pressure sensors Binary sensors (thermostats, hygrostats, pressostats, fan belt protection, frost protection) Overview binary sensor technology ([%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3D 5HG%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3D ,Q%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3DQRW([ ([%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« & 5HG%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« & ,Q%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« &QRW([ ([%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQ 5HG%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQ ,Q%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQQRW([ ([%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU([3UR%«SUREHVHQVRUV 5HG%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU([3UR%«SUREHVHQVRUV ,Q%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU,Q3UR%«SUREHVHQVRUVQRW([ ([3UR%« GLJLWDOWKHUPRVWDW K\JURVWDWVHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPV ,Q3UR%« GLJLWDOWKHUPRVWDW K\JURVWDWVHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPVQRW([ ExBin-A modules for adaptation of 1-5 passive, potential free, binary ExSens sensors RedBin-A modules for adaptation of 1-5 passive, potential free, binary ExSens sensors ,Q%LQ$ PRGXOHVIRUDGDSWDWLRQRISDVVLYHSRWHQWLDOIUHHELQDU\VHQVRUVQRW([ ExLine switching module EXL-IRU-1 for passive, potential free, binary ExSens sensors ExSens binary, passive temperature- /humidity- /pressure sensors Special options for sensors Overview special options for sensors Overview heating system ExPolar for sensors ([3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQ([DUHDVGRZQWRí& ,Q3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQVDIHDUHDGRZQWRí&QRW([ Installation areas in zone Page Gas 0 Dust 20 32-34 38 38 39 39 40-42 48 48 49 49 Dust 21 Gas 2 Dust 22 SA* z z z z z z z z z z z z z z z z z z z z z z z z z z z z z 22-23 24 Gas 1 z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z 50 51 z z z z z z z z z z z z z z z *SA = Safe area z RQUHTXHVW 6 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Table of contents Product series Door holder magnets ([0DJ GRRUKROGHUPDJQHWVZLWK1IRUFH Components ([&RPS GLIIHUHQW([FRPSRQHQWVHJVZLWFKHVSXVKEXWWRQV« Additional information Product codes /definitions ,QVWDOODWLRQDFFRUGLQJWR$7(;=RQHV\VWHP ,QVWDOODWLRQDFFRUGLQJWR1(&'LYLVLRQV\VWHP1RUWK$PHULFD 9DOYHDXWRPDWLRQ &HUWLILFDWLRQLQIRUPDWLRQ ,QIRUPDWLRQDERXW$7(;(& /DEHOOLQJRIH[SORVLRQSURRIHTXLSPHQWDFFRUGLQJWR$7(; ([SORVLRQSURRILQIRUPDWLRQV ,QIRUPDWLRQDERXW]RQHVH[SORVLRQJURXSVDQGWHPSHUDWXUHFODVVHV ([DSSOLFDWLRQV 6,/³6DIHW\,QWHJULW\/HYHO´ Rotork products 1RWLFHV General conditions Installation areas in zone Page Gas 0 Dust 20 Gas 1 Dust 21 Gas 2 Dust 22 z z z z z z z z SA* 54-55 70-73 74-75 75 *SA = Safe area z RQUHTXHVW www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 7 Price list 2014 Technical short info 2014 Introducing ExMax – Damper actuators for explosion proof areas! Quarter turn and rotary applications for damper control ... HAZARDOUS LOCATIONS ZONE 1, 2, 21, 22 FAST SPRING RETURN TIME SIL2 FAIL SAFE FUNCTION UNIVERSAL POWER SUPPLY STAINLESS STEEL SOLUTION EASY INSTALLATION COMPACT DIMENSIONS 8 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ..Max(OHFWULFDOGULYHHQJLQHHULQJZLWKDQJOHRIURWDWLRQ±2YHUYLHZ Overview ..Max quarter turn actuators The actuator series are subdivided in 3 installation- and 5 application areas. The actuator concept offers obvious advantages: Installation areas: ExMax- ..................... actuators for use in hazardous areas zone 1, 2, 21, 22 RedMax- ................... actuators for use in hazardous areas zone 2, 22 InMax- ....................... actuators for use in safe area 1. 2. 3. 4. 5. 7. 8. 9. 10. Application areas: Ex/ Red/ InMax ......... IRUDLUDQGILUHGDPSHUV9$9FRQWUROEDOOYDOYHVFRQWUROGDPSHUV Small dimension, compact, easy installation, highest protection classes, cost effective 8QLYHUVDOSRZHUVXSSO\WR9ROW$&'&VHOIDGMXVWDEOH SIL2 fail safe function :LWKRUZLWKRXWVSULQJUHWXUQLQDFFZLWKW\SH 5REXVWDOXPLQLXPKRXVLQJ,3RSWLRQDOLQVWDLQOHVVVWHHO Integrated heater for low temperatures On site adjustable motor running time Integrated manual override Useful accessories such as retrofit limit switches Actuators are direct coupling Actuators for air-dampers ExMax.., RedMax.., InMax.. ¼ turn actuators DFWXDWRUVIURPWR1PZLWKRUZRVSULQJ UHWXUQ UXQQLQJ WLPH V GHSHQGLQJ RQ W\SHIRUDLUGDPSHUV Nm ExMax 95° normal wiring Actuators for smoke- and fire-dampers ExMax.., RedMax.., InMax.. ¼ turn actuators DFWXDWRUVIURPWR1PZLWKRUZRVSULQJ UHWXUQ UXQQLQJ WLPH V GHSHQGLQJ RQ W\SHIRUVPRNHDQGILUHGDPSHUV Nm ExMax 95° normal wiring $FWXDWRUVIRU9$9FRQWURO ExMax.., RedMax.., InMax.. ¼ turn actuators DFWXDWRUVIURPWR1PZLWKRUZRVSULQJ UHWXUQ UXQQLQJ WLPH V GHSHQGLQJ RQ W\SHIRU9$9FRQWURO Nm ExMax 95° normal wiring Actuators for ball valves ExMax.., RedMax.., InMax.. ¼ turn actuators DFWXDWRUVIURPWR1PZLWKRUZRVSULQJ UHWXUQ UXQQLQJ WLPH V GHSHQGLQJ RQ W\SHIRUEDOOYDOYHV Nm ExMax 95° normal wiring Actuators for butterfly valves and other ¼ turn valves ExMax.., RedMax.., InMax.. ¼ turn actuators DFWXDWRUVIURPWR1PZLWKRUZRVSULQJ UHWXUQ UXQQLQJ WLPH V GHSHQGLQJ RQ W\SH IRU EXWWHUIO\ YDOYHV DQG RWKHU TXDUWHU WXUQ valves. Nm ExMax 95° normal wiring Safe area Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 9 Price list 2014 Technical short info 2014 ExMax([TXDUWHUWXUQDFWXDWRUVVL]H³6´IRU]RQH Explosion proof Features of ExMax - ... size S Size S ExMax-… =RQH Gas + Dust Description Basics for all ExMax-.. size S ExMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. certified according ATEX, SIL, IECEx, *2675571 Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. ,10(752.26+$ UL*, CSA*, «$YHUVLRQRQO\ 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override Squared shaft connection 12 × 12 mm 'LPHQVLRQV+î:î'îîPP Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax- 5.10 ExMax-15.30 ExMax- 5.10-S ExMax-15.30-S ExMax- 5.10-Y ExMax-15.30-Y 1P1P 1P1P 1P1P 1P1P 1P1P 1P1P VHF VHF VHF VHF VHF VHF Feedback Features 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Size 6 6 6 6 6 6 Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax-5.10- F ExMax- 15- F ExMax-5.10-SF ExMax- 15-SF ExMax-5.10-YF ExMax- 15-YF ExMax-5.10-BF ExMax- 15-BF 1P1P 1P 1P1P 1P 1P1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 6 6 6 6 6 6 6 6 Ex-d quarter turn actuators with 1 sec. spring return for Offshore application, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax- 8- F1 ExMax-15- F1 ExMax- 8-SF1 ExMax-15-SF1 ExMax- 8-BF1 ExMax-15-BF1 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 6 6 6 6 6 6 Accessories Type Technical data ExSwitch ExBox-3P ExBox-3P/SW ExBox-Y/S ExBox-Y/S/SW ExBox-BF ExBox-BF/SW MKK-S KB-S HV-SK, HV-SL AR-12-xx ExPro-TT-… Retrofit-Kit ..Max-S External, adaptable, on site adjustable Ex-d auxiliary switch with 2 potential free contacts, adaptable to ExMax-... actuators ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH([6ZLWFK ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUDOO([0D[%) ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUDOO([0D[%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH([6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[DFWXDWRUVVL]H6 0RXQWLQJFODPSIRUURXQGGDPSHUVKDIWWRPPDQGVTXDUHGVKDIWVWRPPLQFOEUDFNHWFRQQHFWDEOHWRDOO([0D[VL]H6 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H6+96. VKRUWYHUVLRQ+96/ ORQJYHUVLRQIRUDGGPRXQWLQJRI%R[ 6ZLWFKQRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU([0D[ 5HG0D[«%)DFWXDWRUV 0HFKDQLFDODGDSWDWLRQIRUPRXQWLQJRQ0D[DFWXDWRUVVL]H6UHTXLUHGWRUHSODFHDSUHYLRXVW\SH(;7)(;7)(;7RU(;7 Special options and offshore kits see page 23 10 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExMax([TXDUWHUWXUQDFWXDWRUVVL]H³0´IRU]RQH Explosion proof Features of ExMax - ... size M Size M ExMax-… =RQH Gas + Dust Description Basics for all ExMax-.. size M ExMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. certified according ATEX, SIL, IECEx, *2675571 Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. ,10(752 UL*, CSA*, «$YHUVLRQRQO\ 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override 6TXDUHGVKDIWFRQQHFWLRQîPP 'LPHQVLRQV+î:î'îîPP Ex-d quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax-50.75 ExMax- 100 ExMax- 150 ExMax-50.75-S ExMax- 100-S ExMax- 150-S ExMax-50.75-Y ExMax- 100-Y 1P1P 1P 1P 1P1P 1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF Feedback 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Features Size 0 0 0 0 0 0 0 0 Ex-d quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax-30- F ExMax-50- F ExMax-60- F ExMax-30-SF ExMax-50-SF ExMax-60-SF ExMax-30-YF ExMax-50-YF ExMax-30-BF ExMax-50-BF ExMax-60-BF 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 0 0 0 0 0 0 0 0 0 0 0 Ex-d quarter turn actuators with 3 sec. spring return for Offshore application, 24 to 240 VAC/DC, for zone 1, 2, 21, 22 Type Torque Running time 90° Spring return Control mode ExMax-30- F3 ExMax-50- F3 ExMax-30-SF3 ExMax-50-SF3 ExMax-30-BF3 ExMax-50-BF3 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 0 0 0 0 0 0 Accessories Type Technical data ExSwitch ExBox-3P ExBox-3P/SW ExBox-Y/S ExBox-Y/S/SW ExBox-BF ExBox-BF/SW MKK-M HV-MK AR-16-xx ExPro-TT-… Retrofit-Kit ..Max-M External, adaptable, on site adjustable Ex-d auxiliary switch with 2 potential free contacts, adaptable to ExMax-... actuators ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH([6ZLWFK ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUDOO([0D[%) ([HWHUPLQDOER[FRQQHFWDEOHWR([0D[«DFWXDWRUVZLWKFDEOHIRUDOO([0D[%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH([6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[DFWXDWRUVVL]H0 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H0QRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU([0D[ 5HG0D[«%)DFWXDWRUV Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type EXT30..-F3, EXT50..-F3 or EXT50.. Special options and offshore kits see page 23 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 11 Price list 2014 Technical short info 2014 RedMax([TXDUWHUWXUQDFWXDWRUV³6´IRU]RQH Explosion proof Features of RedMax - ... size S Size S RedMax-… =RQH Gas + Dust certified according ATEX, SIL, IECEx, *2675571 UL*, CSA*, Description Basics for all RedMax-.. size S RedMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. «$YHUVLRQRQO\ 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override Squared shaft connection 12 × 12 mm 'LPHQVLRQV+î:î'îîPP Ex-n quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax- 5.10 RedMax-15.30 RedMax- 5.10-S RedMax-15.30-S RedMax- 5.10-Y RedMax-15.30-Y 1P1P 1P1P 1P1P 1P1P 1P1P 1P1P VHF VHF VHF VHF VHF VHF Feedback 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Features Size 6 6 6 6 6 6 Ex-n quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax-5.10- F RedMax- 15- F RedMax-5.10-SF RedMax- 15-SF RedMax-5.10-YF RedMax- 15-YF RedMax-5.10-BF RedMax- 15-BF 1P1P 1P 1P1P 1P 1P1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 6 6 6 6 6 6 6 6 Ex-n quarter turn actuators with 1 sec. spring return for Offshore application, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax- 8- F1 RedMax-15- F1 RedMax- 8-SF1 RedMax-15-SF1 RedMax- 8-BF1 RedMax-15-BF1 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 6 6 6 6 6 6 Accessories Type Technical data RedSwitch RedBox-3P RedBox-3P/SW RedBox-Y/S RedBox-Y/S/SW RedBox-BF RedBox-BF/SW MKK-S KB-S HV-SK, HV-SL AR-12-xx ExPro-TT-… Retrofit-Kit ..Max-S External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to RedMax-... actuators ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH5HG6ZLWFK ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUDOO5HG0D[«%) ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUDOO5HG0D[«%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH5HG6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[«DFWXDWRUVVL]H6 0RXQWLQJFODPSIRUURXQGGDPSHUVKDIWWRPPDQGVTXDUHGVKDIWVWRPPLQFOEUDFNHWFRQQHFWDEOHWRDOO5HG0D[«VL]H6 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H6+96. VKRUWYHUVLRQ+96/ ORQJYHUVLRQIRUDGGPRXQWLQJRI%R[ 6ZLWFKQRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU([0D[ 5HG0D[«%)DFWXDWRUV 0HFKDQLFDODGDSWDWLRQIRUPRXQWLQJRQ0D[DFWXDWRUVVL]H6UHTXLUHGWRUHSODFHDSUHYLRXVW\SH(;7)(;7)(;7RU(;7 Special options and offshore kits see page 23 12 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 RedMax([TXDUWHUWXUQDFWXDWRUV³0´IRU]RQH Explosion proof RedMax-… =RQH Gas + Dust certified according ATEX, SIL, IECEx, *2675571 UL*, CSA*, Features of RedMax - ... size M Size M Description Basics for all RedMax-.. size M RedMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. «$YHUVLRQRQO\ 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override 6TXDUHGVKDIWFRQQHFWLRQîPP 'LPHQVLRQV+î:î'îîPP Ex-n quarter turn actuators without spring return, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax-50.75 RedMax- 100 RedMax- 150 RedMax-50.75-S RedMax- 100-S RedMax- 150-S RedMax-50.75-Y RedMax- 100-Y 1P1P 1P 1P 1P1P 1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF Feedback 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Features Size 0 0 0 0 0 0 0 0 Ex-n quarter turn actuators with spring return, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax-30- F RedMax-50- F RedMax-60- F RedMax-30-SF RedMax-50-SF RedMax-60-SF RedMax-30-YF RedMax-50-YF RedMax-30-BF RedMax-50-BF RedMax-60-BF 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 0 0 0 0 0 0 0 0 0 0 0 Ex-n quarter turn actuators with 3 sec. spring return for Offshore application, 24 to 240 VAC/DC, for zone 2, 22 Type Torque Running time 90° Spring return Control mode RedMax-30- F3 RedMax-50- F3 RedMax-30-SF3 RedMax-50-SF3 RedMax-30-BF3 RedMax-50-BF3 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ([3UR77FRQQHFWRU ([3UR77FRQQHFWRU Size 0 0 0 0 0 0 Accessories Type Technical data RedSwitch RedBox-3P RedBox-3P/SW RedBox-Y/S RedBox-Y/S/SW RedBox-BF RedBox-BF/SW MKK-M HV-MK AR-16-xx ExPro-TT-… Retrofit-Kit ..Max-M External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to RedMax-... actuators ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH5HG6ZLWFK ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUDOO5HG0D[«%) ([HWHUPLQDOER[FRQQHFWDEOHWR5HG0D[«DFWXDWRUVZLWKFDEOHIRUDOO5HG0D[«%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH5HG6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[«DFWXDWRUVVL]H0 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H0QRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU([0D[ 5HG0D[«%)DFWXDWRUV Mechanical adaptation for mounting on ..Max actuators size M, required to replace a previous type EXT30..-F3, EXT50..-F3 or EXT50.. Special options and offshore kits see page 23 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 13 Price list 2014 Technical short info 2014 InMaxTXDUWHUWXUQDFWXDWRUV³6´IRUVDIHDUHD Industrial Features of InMax - ... size S Size S InMax-… 127([SORVLRQSURRI and only for use in safe area ,3 Description Basics for all InMax-.. size S InMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override Squared shaft connection 12 × 12 mm 'LPHQVLRQV+î:î'îîPP Quarter turn actuators without spring return, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax- 5.10 InMax-15.30 InMax- 5.10-S InMax-15.30-S InMax- 5.10-Y InMax-15.30-Y 1P1P 1P1P 1P1P 1P1P 1P1P 1P1P VHF VHF VHF VHF VHF VHF Feedback 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Features Size 6 6 6 6 6 6 Quarter turn actuators with spring return, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax-5.10-F InMax- 15-F InMax-5.10-SF InMax- 15-SF InMax-5.10-YF InMax- 15-YF InMax-5.10-BF InMax- 15-BF 1P1P 1P 1P1P 1P 1P1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF aVHFVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV ,Q3UR77FRQQHFWRU ,Q3UR77FRQQHFWRU Size 6 6 6 6 6 6 6 6 Quarter turn actuators with 1 sec. spring return for Offshore application, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax- 8-F1 InMax-15-F1 InMax- 8-SF1 InMax-15-SF1 InMax- 8-BF1 InMax-15-BF1 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ,Q3UR77FRQQHFWRU ,Q3UR77FRQQHFWRU Size 6 6 6 6 6 6 Accessories Type Technical data InSwitch InBox-3P InBox-3P/SW InBox-Y/S InBox-Y/S/SW InBox-BF InBox-BF/SW MKK-S KB-S HV-SK, HV-SL AR-12-xx InPro-TT-… Retrofit-Kit ..Max-S External, adaptable, on site adjustable auxiliary switch with 2 potential free contacts, adaptable to InMax-... actuators 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH,Q6ZLWFK 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUDOO,Q0D[«%) 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUDOO,Q0D[«%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH,Q6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[«DFWXDWRUVVL]H6 0RXQWLQJFODPSIRUURXQGGDPSHUVKDIWWRPPDQGVTXDUHGVKDIWVWRPPLQFOEUDFNHWFRQQHFWDEOHWRDOO,Q0D[«VL]H6 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H6+96. VKRUWYHUVLRQ+96/ ORQJYHUVLRQIRUDGGPRXQWLQJRI%R[ 6ZLWFKQRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU,Q0D[«%)DFWXDWRUV 0HFKDQLFDODGDSWDWLRQIRUPRXQWLQJRQ0D[DFWXDWRUVVL]H6UHTXLUHGWRUHSODFHDSUHYLRXVW\SH127)127)127RU127 Special options and offshore kits see page 23 14 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 InMaxTXDUWHUWXUQDFWXDWRUV³0´IRUVDIHDUHD Industrial InMax-… 127([SORVLRQSURRI and only for use in safe area ,3 Features of InMax - ... size M Size M Description Basics for all InMax-.. size M InMax are, in acc. with type, for automation of air dampers, fire and smoke dampers, volume control, as well as for ball valves, throttle valves and other quarter turn armatures. Delivery: DFWXDWRUaPFDEOHDOOHQNH\IRUPDQXDORYHUULGH 4 screws. 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site DQJOHRIURWDWLRQIRUSUHWHQVLRQ 100% overload protected $OXPLQLXPKRXVLQJ,3FDEOHaP & &LQWHJUDWHGKHDWHU Emergency manual override 6TXDUHGVKDIWFRQQHFWLRQîPP 'LPHQVLRQV+î:î'îîPP Quarter turn actuators without spring return, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax-50.75 InMax- 100 InMax- 150 InMax-50.75-S InMax- 100-S InMax- 150-S InMax-50.75-Y InMax- 100-Y 1P1P 1P 1P 1P1P 1P 1P 1P1P 1P VHF VHF VHF VHF VHF VHF VHF VHF Feedback 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV 2QRIISRV îDX[VZLWFKHV SRV«9'&P$ «9'&P$ SRV«9'&P$ «9'&P$ Features Size 0 0 0 0 0 0 0 0 Quarter turn actuators with spring return, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax-30- F InMax-50- F InMax-60- F InMax-30-SF InMax-50-SF InMax-60-SF InMax-30-YF InMax-50-YF InMax-30-BF InMax-50-BF InMax-60-BF 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF aVHF 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV 2QRIISRV SRV«9'&P$ SRV«9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV «9'&P$ «9'&P$ îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ,Q3UR77FRQQHFWRU ,Q3UR77FRQQHFWRU ,Q3UR77FRQQHFWRU Size 0 0 0 0 0 0 0 0 0 0 0 Quarter turn actuators with 3 sec. spring return for Offshore application, 24 to 240 VAC/DC, for safe area Type Torque Running time 90° Spring return Control mode InMax-30- F3 InMax-50- F3 InMax-30-SF3 InMax-50-SF3 InMax-30-BF3 InMax-50-BF3 1P 1P 1P 1P 1P 1P VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF VHF 2QRII 2QRII 2QRII 2QRII 2QRII 2QRII Feedback Features îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV îDX[VZLWFKHV ,Q3UR77FRQQHFWRU ,Q3UR77FRQQHFWRU Size 0 0 0 0 0 0 Accessories Type Technical data InSwitch InBox-3P InBox-3P/SW InBox-Y/S InBox-Y/S/SW InBox-BF InBox-BF/SW MKK-M HV-MK AR-16-xx InPro-TT-… Retrofit-Kit ..Max-M ([WHUQDODGDSWDEOHRQVLWHDGMXVWDEOHDX[LOLDU\VZLWFKZLWKSRWHQWLDOIUHHFRQWDFWVDGDSWDEOHWR,Q0D[«DFWXDWRUV 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQ 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRU2QRIIRUSRVRSHUDWLRQFDEOHIRUH[WHUQDODX[VZLWFKHVW\SH,Q6ZLWFK 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRSHUDWLRQRUSRVLQWHJUDWHGVZLWFKHV+6 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUPRGXODWLQJRUSRVRSHUDWLRQZLWKIHHGEDFNVLJQDOFDEOHIRUH[WHUQDODX[VZLWFKHV 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUDOO,Q0D[«%) 7HUPLQDOER[FRQQHFWDEOHWR,Q0D[«DFWXDWRUVZLWKFDEOHIRUDOO,Q0D[«%)FDEOHIRUH[WHUQDODX[VZLWFKHVW\SH,Q6ZLWFK 0RXQWLQJEUDFNHWIRU«%R[WHUPLQDOER[HVIRUGLUHFWFRXSOLQJWR«0D[«DFWXDWRUVVL]H0 0DQXDORYHUULGHFRQQHFWDEOHWRDFWXDWRUVVL]H0QRWVXLWDEOHIRU0D[) 6TXDUHGUHGXFWLRQSDUWIURPîPPWRVKDIWVZLWKPPW\SH$5PPW\SH$5 6DIHW\WHPSHUDWXUHWULJJHUIRUILUHGDPSHUVVZLWFKLQJDW &ZLWKPFDEOHVXLWDEOHRQO\IRU,Q0D[«%)DFWXDWRUV 0HFKDQLFDODGDSWDWLRQIRUPRXQWLQJRQ0D[DFWXDWRUVVL]H0UHTXLUHGWRUHSODFHDSUHYLRXVW\SH127)127)RU127 Special options and offshore kits see page 23 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 15 Price list 2014 Technical short info 2014 Introducing ExMax+LIN&ExRun – Valve actuators for explosion proof areas! Linear applications for valve control ... HAZARDOUS LOCATIONS ZONE 1, 2, 21, 22 FAST SPRING RETURN TIME SIL2 FAIL SAFE FUNCTION UNIVERSAL POWER SUPPLY C5-M SOLUTION EASY INSTALLATION COMPACT DIMENSIONS 16 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ..Max + LIN, ..Run Electrical drive engineering for valves – Overview 2YHUYLHZ0D[/,1OLQHDUJXLGHXQLWDQG5XQYDOYHDFWXDWRUV The actuator series are subdivided in 3 installation- and 2 application areas. The actuator concept offers obvious advantages: Installation areas: ExMax-..+LIN, ExRun-.. ........................ actuators for use in hazardous areas zone 1, 2, 21, 22 RedMax-..+LIN, RedRun-.. ................... actuators for use in hazardous areas zone 2, 22 InMax-..+LIN, InRun-.. .......................... actuators for use in safe area 1. 2. 3. 4. 5. 7. 8. 9. Application areas: Ex/Red/InMax + LIN ............................. IRUJOREHRUZD\YDOYHVZLWKVDIHW\IXQFWLRQ Ex/Red/InRun ....................................... for globe- or 3-way valves Small dimension, compact, easy installation, highest protection classes, cost effective 8QLYHUVDOSRZHUVXSSO\WR9ROW$&'&VHOIDGMXVWDEOH 6,/IDLOVDIHIXQFWLRQRQO\DW0D[/,1 :LWKRUZLWKRXWVSULQJUHWXUQVSULQJUHWXUQRQO\DW0D[/,1OLQHDUJXLGHXQLW 5REXVWDOXPLQLXPKRXVLQJ,3 Integrated heater for low temperatures On site adjustable motor running time Integrated manual override Useful accessories such as retrofit limit switches Actuators with spring return for 2-way and 3-way valves N ExMax+LIN ExMax.., RedMax.., InMax.. + LIN linear guide unit Linear motion valve actuators with spring return IURP WR 1 )L[HG VWURNH ZLWK 15, 20, 30, or 42 mm, for automation of globe- or 3-way valves. Linkage to numerous valve types and brands available. 7,5 mm 42 mm normal wiring Actuators for 2-way and 3-way valves N ExRun.., RedRun.., InRun.. valve actuators 9DOYHDFWXDWRUVIURPWR12QVLWHDGMXVWDEOHVWURNHIURPWRPPIRUDXWRPDWLRQRI globe- or 3-way valves. Linkage to numerous valve types and brands available. ExRun 5 mm 60 mm normal wiring www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 17 Price list 2014 Technical short info 2014 ..Max-.. + LIN-.. Linear valve actuators size “S” and “M” with spring return Explosion proof ExMax-.. + LIN-.. =RQH Gas + Dust certified according ATEX, SIL, IECEx, *2675571 ,10(752.26+$1 1 Industrial RedMax-.. + LIN-.. =RQH Gas + Dust certified according ATEX, SIL, IECEx, *2675571 ,10(752, UL*, CSA* InMax-.. + LIN-.. 127([SORVLRQSURRI and only for use in safe area ,3 )HDWXUHV0D[/,1VL]H6DQG0 Basics for ..Max-.. + LIN-.. valve actuators Description 0D[/,1OLQHDUYDOYHDFWXDWRUVwith spring return for automation of globe- or 3-way valves. Use as actuator with safety function, On-off or 3-pos. actuator or modulating actuator. Delivery: Linear unit, suitable for all ..Max-..-F actuators size S or M. «$YHUVLRQRQO\ ExMax size S only Required accessories: 9DOYHDGDSWDWLRQLQDFFRUGDQFHZLWKYDOYH manufacturer, type and nominal size GLDPHWHU UL*, CSA* «$YHUVLRQRQO\ Ordering example: Modulating valve actuator with spring return in Ex area zone 2, for a globe valve with PPVWURNHDQGDUHTXLUHGIRUFHRI1 «9$&'&VHOIDGDSWDEOHSRZHU supply 5XQQLQJWLPH«VHFPPï 6WURNHPPï )RUFH«1ï 6SULQJUHWXUQVHFVL]H6 VHFVL]H0ï &RQWUROPRGH2QRIISRV9'& P$ï $OXPLQLXPKRXVLQJ,3ð $PELHQWWHPSHUDWXUHí«&7 í«&7 :HLJKWLQFODFWXDWRUaNJVL]H6 aNJVL]H0ï ([WHUQDOWHUPLQDOER[RSWLRQDOð ïLQDFFZLWKW\SH_ðDSSOLHVIRUDFWXDWRU Actuator: RedMax-30-YF /LQHDUDGDSWDWLRQ/,1 9DOYHDGDSWDWLRQVXLWDEOHIRUYDOYHW\SHRQUHTX 2SWLRQDO ([WHUPLQDOER[5HG%R[<6 2SWLRQDO 0RXQWLQJEUDFNHW0..0 Linear unit for actuators with spring return, 24 to 240 VAC/DC Type Stroke (max.) Description LIN-7.5 LIN-10 LIN-15 LIN-20 LIN-30 LIN-40 7,5 mm 10 mm 15 mm 20 mm 30 mm 42 mm Linear unit up to max. 7,5 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Linear unit up to max. 10 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Linear unit up to max. 15 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Linear unit up to max. 20 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Linear unit up to max. 30 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Linear unit up to max. 42 mm stroke, suitable for all ..Max-..-F actuators size S or M with spring return Additional price for adaptation, dependent on valve manufacturer, -type and stroke. LIN Special options for linear unit suitable for actuators Explosion proof /Safe area LIN-…CT available for linear XQLW/,1 In accordance with ..Max type for use in Ex area or safe area )HDWXUHV/,1«&7 Special options Description CT version with aluminium housing and C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated. Delivery: Ordering example: Basics LIN-…-CT CT: C5-M painted aluminium housing Resistant against corrosive and /or maritime atmosphere 1 linear unit with special option /,1&7 LIN-.. options Type Description/ Technical data LIN-..-CT &0SDLQWHGDOXPLQLXPKRXVLQJUHVLVWDQWDJDLQVWFRUURVLYHDQG RUPDULWLPHDWPRVSKHUH/LIWLQJURGFRQQHFWLQJSDUWVDQGVFUHZVLQ9$VXUFKDUJH $GGLWLRQDOSULFHIRUDGDSWDWLRQLQVWDLQOHVVVWHHO9$IRU&7YHUVLRQ 18 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 9DOYHDGDSWDWLRQ Mounting variations To select the right valve adaptation and get the right price information the following data are required: 1. Valve manufacturer 2. Valve type 3. Valve nominal size (diameter) DN For adaptations which are already designed by Schischek this information is sufficient. To design new adaptations we need additional details of the valve body as well as drawings. Actuator ..Max-..-F LIN-.. Adaption Valve actuator with spring return With the purchase order you have to provide actuator type + type of adaptation. Selection of recommended actuators in relation of force and max. stroke At strokes between two values use the next higher linear unit HJPPVWURNH /,1 Attention: /LPLWDWLRQRIUHVROXWLRQDW<)DFWXDWRUVZLWKVWURNHVQRPLQDOPRWRUEORFNDGH 1RWHWKHPD[LPXPIRUFHRIWKHDFWXDWRUWRSUHYHQWGDPDJHWR\RXUYDOYH Info: Suitable actuators with spring return see page 10-15. 1RPLQDOIRUFH1DWVSULQJRIDFWXDWRULQUHODWLRQRIPD[VWURNHRI/,1DWWHPSHUDWXUHVEHWZHHQî«& Attention: /LPLWDWLRQRIUHVROXWLRQDW<)DFWXDWRUVZLWKVWURNHVQRPLQDOPRWRUEORFNDGH 1RWHWKHPD[LPXPIRUFHRIWKHDFWXDWRUWRSUHYHQWGDPDJHWR\RXUYDOYH Nominal force (N) at spring of actuator in relation of max. stroke of LIN at temperatures between 0…+40 °C Attention: $ERYHPHQWLRQHGYDOXHVDUHQRPLQDOWUXVWVZLWKSHUIRUPHGVHOIDGMXVWPHQWGULYH 7KHPD[LPXPWUXVWVFDQUHDGYDOXHVZKLFKDUHXSWRWKUHHWRIRXUWLPHVKLJKHUWKDQYDOXHVRIWDEOHV :LWKRXWSHUIRUPHGVHOIDGMXVWPHQWGULYHWKHUHFDQRFFXUPXFKKLJKHUWUXVWYDOXHVZKLFKFDQFDXVHGDPDJHVRQWKHPHQWLRQHGYDOYHRUOLQNDJHV www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 19 Price list 2014 Technical short info 2014 ExRun/ RedRun/ InRun9DOYHDFWXDWRUV Industrial Explosion proof ExRun... =RQH Gas + Dust certified according ATEX, IECEx, *2675571 .26+$8/&6$ RedRun... =RQH Gas + Dust certified according ATEX, IECEx, *2675571 UL*, CSA* Features of ExRun, RedRun, InRun InRun… 127([SORVLRQSURRI and only for use in safe area ,3 Description Basics for all …Run valve actuators ExRun, RedRun and InRun valve actuators are used for automation of 2- and 3-way valves with 3-pos. on-off or modulating mode. 24…240 VAC/DC self adaptable power supply Up to 5 different running times adjustable on site WRPPVWURNHPHFKDQLFDOOLPLWDWLRQ on each position Automatic adaptation of modulating signal DW([5HG,Q5XQ«< $OXPLQLXPKRXVLQJ,3LQWHJUDWHG terminal box í«& &LQWHJUDWHGKHDWHU Emergency manual override 'LPHQVLRQ+ 1 î:î' 1 × 208 × 115 mm ZLWKRXWYDOYHDQGDGDSWDWLRQ $SSUR[LPDWHZHLJKW«NJ 2 ZLWKRXWYDOYHDQGDGDSWDWLRQ Delivery: 1 actuator with integrated Ex-e terminal box, Emergency manual override. «$YHUVLRQRQO\ «$YHUVLRQRQO\ Required accessories: 9DOYHDGDSWDWLRQLQDFFRUGDQFHZLWK valve manufacturer, type and nominal size GLDPHWHU 1 2 Height varies depending on type Weight varies depending on type Ex-d valve actuators without spring return for zone 1, 2, 21, 22 Type Force Running time ExRun- 5.10 ExRun-25.50 ExRun-75.100 ExRun- 5.10 -Y ExRun-25.50 -Y ExRun-75.100-Y ExRun- 5.10 -U ExRun-25.50 -U ExRun-75.100-U 1 1 11 1 1 11 1 1 11 VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP Spring return Control mode 2QRIISRV 2QRIISRV 2QRIISRV «9'&P$ «9'&P$ «9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ Features Size 6 6 6 6 6 6 6 6 6 Features Size 6 6 6 6 6 6 6 6 6 Features Size 6 6 6 6 6 6 6 6 6 Ex-n valve actuators without spring return for zone 2, 22 Type Force Running time RedRun- 5.10 RedRun-25.50 RedRun-75.100 RedRun- 5.10 -Y RedRun-25.50 -Y RedRun-75.100-Y RedRun- 5.10 -U RedRun-25.50 -U RedRun-75.100-U 1 1 11 1 1 11 1 1 11 VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP Spring return Control mode 2QRIISRV 2QRIISRV 2QRIISRV «9'&P$ «9'&P$ «9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ Valve actuators without spring return for safe area Type Force Running time InRun- 5.10 InRun-25.50 InRun-75.100 InRun- 5.10 -Y InRun-25.50 -Y InRun-75.100-Y InRun- 5.10 -U InRun-25.50 -U InRun-75.100-U 1 1 11 1 1 11 1 1 11 VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP VHFPP 20 Spring return Control mode 2QRIISRV 2QRIISRV 2QRIISRV «9'&P$ «9'&P$ «9'&P$ 2QRIISRV 2QRIISRV 2QRIISRV Feedback «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ «9'&P$ www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Accessories Type Technical data ExSwitch-R-L InSwitch- R-L ExBox- SW RedBox-SW InBox- SW MKK-S HV-R GMB-1 Adaption External, adaptable, on site adjustable Ex-d auxiliary switch linear for Ex/RedRun-.. with 2 potential free contacts, additionally Ex-e terminal box + mounting bracket necessary External, adaptable, on site adjustable auxiliary switch linear for InRun-.. with 2 potential free contacts, additionally terminal box + mounting bracket necessary Ex-e terminal box suitable for ExRun.. valve-actuators with external switches ExSwitch-R-L Ex-e terminal box suitable for RedRun.. valve-actuators with external switches ExSwitch-R-L Terminal box suitable for InRun.. valve-actuators with external switches InSwitch-R-L Mounting-bracket suitable for ..Box-terminal boxes for direct mounting on ..Run actuators size S Manual override suitable for ..Run valve actuators size S 5XEEHUEHOORZXSWRPPFRORXUEODFN Different adaptations for different valve types and sizes available. Please don‘t hesitate to ask for technical solution Special options and offshore kits see page 23 «5XQYDOYHDGDSWDWLRQ Required data for valve adaptation To select the right valve adaptation and get the right price information the ([5XQ« following data are required: 1. Valve manufacturer 5HG5XQ« 2. Valve type 3. Valve nominal size (diameter) DN For adaptations which are already designed by Schischek this information is sufficient. ,Q5XQ« To design new adaptations we need additional details of the valve body as well as drawings. With the purchase order you have to provide actuator type and type of adaptation. Adaption www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 21 Price list 2014 Technical short info 2014 VA/ CT Special options actuators – overview Overview of special options of Schischek actuators for use under extreme weather conditions Installation/ Application area: Advantages of special options: Usage in hazardous areas under extreme weather conditions and /or for offshore/ onshore applications. Resistant against corrosive and /or maritime atmosphere Usage under extreme weather conditions Approved for offshore- /onshore applications Robust and thereby extended period of application time of actuators Special options quarter turn actuators size S ..Max-.. ¼ turn actuators size S +RXVLQJ PDWHULDO LQ VWDLQOHVV VWHHO 9$6 RU DOXPLQLXP KRXVLQJ ZLWK &0 SDLQWLQJ &76 IRU use under extreme weather conditions. VAS ..Max-.. S CTS 9$6 normal wiring CTS Special options quarter turn actuators size M ..Max-.. ¼ turn actuators size M 6XUURXQGLQJ KRXVLQJ LQ VWDLQOHVV VWHHO 9$0 RU DOXPLQLXP KRXVLQJ ZLWK &0 SDLQWLQJ &70 IRU use under extreme weather conditions. VAM ..Max-.. M CTM 9$0 normal wiring CTM Special options valve actuators ..Run-.. valve actuators $OXPLQLXP KRXVLQJ ZLWK &0 SDLQWLQJ &76 IRU use under extreme weather conditions. CTS ..Run-.. normal wiring CTS Weather shield for quarter turn and valve actuators ..Max-.. ¼ turn and ..Run valve actuators WS-S ..Max-.. S/M WS-M ..Run-.. WS-R Weather shield made of stainless steel for protection against weather influences like rain, sun or snow. normal wiring Safe area 22 WS-S WS-M WS-R Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ..Max Special options for quarter turn actuators size S or M Explosion proof ..Max-…VA/CT )HDWXUHV0D[«9$ &7 Description Special options 9$YHUVLRQZLWKKRXVLQJPDWHULDOLQVWDLQOHVVVWHHO$,6, VRPHSDUWVQLFNHOSODWHG CT version with aluminium housing and C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated. available for ExMax, RedMax and InMax In accordance with type for use in Ex area or safe area Delivery: Ordering example: 1 quarter turn actuator size S or M with special option ([0D[9$6 Basics ..Max-…VA/ CT VA: +RXVLQJPDWHULDOLQVWDLQOHVVVWHHO$,6,VRPHSDUWV nickel plated CT: C5-M painted aluminium housing Resistant against corrosive and /or maritime atmosphere Cable glands brass nickel plated Screws in stainless steel For general basics see ..Max quarter turn actuators. ..Max-.. options Type Description/ Technical data ..Max-…- VAS +RXVLQJPDWHULDORI0D[TXDUWHUWXUQDFWXDWRUVL]H6LQVWDLQOHVVVWHHO$,6,VRPHSDUWVQLFNHOSODWHGVXUFKDUJH ..Max-…- VAM (QFORVXUHIRU0D[TXDUWHUWXUQDFWXDWRUVL]H0PDGHRIVWDLQOHVVVWHHO$,6, ..Max-…- CTS Aluminium housing of ..Max quarter turn actuator size S with C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated VXUFKDUJH ..Max-…- CTM Aluminium housing of ..Max quarter turn actuator size M with C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated VXUFKDUJH ..Box-…/ VA ([HWHUPLQDOER[KRXVLQJPDGHRIVWDLQOHVVVWHHOW\SH$,6,/VRPHSDUWVQLFNHOSODWHGVXUFKDUJH ..Box-…/ CT Ex-e terminal-box, housing C5-M painted, resistant against corrosive /maritime atmosphere, some parts nickel plated VXUFKDUJH ..Switch- CT Auxiliary switch for ..Max.., housing C5-M painted, resistant against corrosive /maritime atmosphere, some parts nickel plated VXUFKDUJH MKK- S/VA 0RXQWLQJEUDFNHWPDGHRIVWDLQOHVVVWHHOVXLWDEOHIRU%R[9$IRUGLUHFWFRXSOLQJWR0D[DFWXDWRUVVL]H6 MKK- M/VA 0RXQWLQJEUDFNHWPDGHRIVWDLQOHVVVWHHOVXLWDEOHIRU%R[9$IRUGLUHFWFRXSOLQJWR0D[DFWXDWRUVVL]H0 MKK-VAM/VA 0RXQWLQJEUDFNHWPDGHRIVWDLQOHVVVWHHOVXLWDEOHIRU%R[9$IRUFRXSOLQJWR0D[DFWXDWRUVVL]H0LQFRPELQDWLRQZLWKVXUURXQGLQJKRXVLQJ9$0 Kit-S8-Max &DEOHJODQGVî0îPP([HVWDQGDUGPPLQEUDVVQLFNHOSODWHGEOLQGSOXJIRUUHSODFHWKHSODVWLFYHUVLRQRITXDUWHUWXUQDFWXDWRU0D[ Kit-S8-Box &DEOHJODQGVî0îPP([HPPEUDVVQLFNHOSODWHGIRUUHSODFHWKHSODVWLFYHUVLRQRIWHUPLQDO%R[ Kit-Offs-PMC-1C Protection metal conduit incl. SS terminal box and glands for 1 armoured cable Kit-Offs-PMC-2C Protection metal conduit incl. SS terminal box and glands for 2 armoured cables WS-S Weather shield in stainless steel, suitable for all ..Max actuators size S WS-M Weather shield in stainless steel, suitable for all ..Max actuators size M ..Run Special options for valve actuators Explosion proof ..Run-…CTS )HDWXUHV5XQ«&76 Description Basics ..Run-…CTS CTS version with aluminium housing and C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated. CTS: C5-M painted aluminium housing Resistant against corrosive and /or maritime atmosphere Cable glands brass nickel plated Screws in stainless steel Special options available for ExRun, RedRun and InRun In accordance with type for use in Ex area or safe area Delivery: Ordering example: 1 valve actuator with special option ExRun-25.50-CTS For general basics see ..Run valve actuators. ..Run-.. options Type Description/ Technical data ..Run-…-CTS $OXPLQLXPKRXVLQJZLWK&0SDLQWLQJIRU5XQYDOYHDFWXDWRUUHVLVWDQWDJDLQVWFRUURVLYH PDULWLPHDWPRVSKHUHVRPHSDUWVQLFNHOSODWHGVXUFKDUJH Kit-S8- &DEOHJODQGVî0îPP([HPPEUDVVQLFNHOSODWHGIRUUHSODFHWKHSODVWLFYHUVLRQRIYDOYHDFWXDWRUV5XQ Run Kit-Offs-GL-Run Cable glands 2 × M25 × 1,5 mm Ex-d in brass nickel plated for armoured cables suitable for ..Run valve actuators WS-R Weather shield in stainless steel, suitable for all ..Run valve actuators www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 23 Price list 2014 Technical short info 2014 ExPolar Heating system – overview 2YHUYLHZRIQHZKHDWLQJV\VWHPIRUXVHZLWK6FKLVFKHNDFWXDWRUVGRZQWRí& Installation/ Application area: Advantages of ExPolar: 8VDJHLQKD]DUGRXVDUHDVIRUWHPSHUDWXUHVGRZQWRí& (VSHFLDOO\IRUXVDJHXQGHUKLJKVXE]HURWHPSHUDWXUHVGRZQWRí& 6XLWDEOHIRUDSSOLFDWLRQVZLWKKLJKWHPSHUDWXUHIOXFWXDWLRQVí&XSWR& Usage directly in hazardous locations Adaptable on Schischek actuator series type ExMax size S or M, ExRun Heating system for quarter turn actuators ExMax size S °C ExPolar-..-MS ExPolar-..-MS Adaptable on Schischek quarter turn actuators type ExMax-.. size S. normal wiring Heating system for quarter turn actuators ExMax size M °C ExPolar-..-MM ExPolar-..-MM Adaptable on Schischek quarter turn actuators type ExMax-.. size M. normal wiring Heating system for valve actuators ExRun °C ExPolar-..-R ExPolar-..-R Adaptable on Schischek valve actuators type ExRun-... normal wiring Safe area 24 Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExPolar/ InPolar Heating system for ¼ turn actuators ..Max-.. size S Explosion proof Industrial ExPolar-…-MS InPolar-…-MS =RQH Gas + Dust certified according ATEX, IECEx 127H[SORVLRQSURRI and only for use in safe area ,3 )HDWXUHV3RODU«06 Description Controlled heating system for use in sub]HURUHJLRQVGRZQWRí&RUDWKLJK WHPSHUDWXUHIOXFWXDWLRQVIURPí& XSWR& Adaptable on Schischek quarter turn actuaWRUV0D[VL]H6GHSHQGLQJRQW\SH Delivery: 1 heating system DGDSWDEOH Ordering example: ExPolar-240-MS Basics ..Polar 9$&'&9$& 40 W í&«& ExPolar for zone 1, 2, 21, 22 InPolar for safe area ExPolar-…-MS/ InPolar-…-MS Type Adaptable on ExPolar-…-MS ([0D[5HG0D[VL]H6 InPolar- …-MS ,Q0D[VL]H6 Supply voltage Operation temperature Supply Power* í&XSWR& í&XSWR& 9$&'&9$&'&9$&9$& 9$&'&9$&'&9$&9$& : ]RQH : VDIHDUHD *Nominal value Installation area VAS option not considered! ExPolar/ InPolar Heating system for ¼ turn actuators ..Max-.. size M Explosion proof Industrial ExPolar-…-MM InPolar-…-MM =RQH Gas + Dust certified according ATEX, IECEx 127H[SORVLRQSURRI and only for use in safe area ,3 )HDWXUHV3RODU«00 Description Controlled heating system for use in sub]HURUHJLRQVGRZQWRí&RUDWKLJK WHPSHUDWXUHIOXFWXDWLRQVIURPí& XSWR& Adaptable on Schischek quarter turn actuaWRUV0D[VL]H0GHSHQGLQJRQW\SH Delivery: 1 heating system DGDSWDEOH Ordering example: ExPolar-240-MM Basics ..Polar 9$&'&9$& : í&«& ExPolar for zone 1, 2, 21, 22 InPolar for safe area ExPolar-…-MM/ InPolar-…-MM Type Adaptable on ExPolar-…-MM ([0D[5HG0D[VL]H0 InPolar- …-MM ,Q0D[VL]H0 Supply voltage Operation temperature Supply Power* í&XSWR& í&XSWR& 9$&'&9$&'&9$&9$& 9$&'&9$&'&9$&9$& : ]RQH : VDIHDUHD *Nominal value Installation area ExPolar/ InPolar Heating system for valve actuators ..Run Explosion proof Industrial ExPolar-…-R InPolar-…-R =RQH Gas + Dust certified according ATEX, IECEx 127H[SORVLRQSURRI and only for use in safe area ,3 )HDWXUHV3RODU«5 Description Controlled heating system for use in sub]HURUHJLRQVGRZQWRí&RUDWKLJK WHPSHUDWXUHIOXFWXDWLRQVIURPí& XSWR& Adaptable on Schischek valve actuators 5XQGHSHQGLQJRQW\SH Delivery: 1 heating system DGDSWDEOH Ordering example: ExPolar-240-R Basics ..Polar 9$&'&9$& : í&«& ExPolar for zone 1, 2, 21, 22 InPolar for safe area ExPolar-…-R/ InPolar-…-R Type Adaptable on ExPolar-…-R ([5XQ5HG5XQ InPolar- …-R ,Q5XQ Supply voltage Operation temperature Supply Power* í&XSWR& í&XSWR& 9$&'&9$&'&9$&9$& 9$&'&9$&'&9$&9$& : ]RQH : VDIHDUHD *Nominal value Installation area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 25 Price list 2014 Technical short info 2014 Introducing ExReg – HVAC control unit for explosion proof areas! 9$9 &$9DQGSUHVVXUHFRQWURODSSOLFDWLRQV HAZARDOUS LOCATIONS ZONE 1, 2, 21, 22 DECENTRALISED CONTROL STRUCTURES REDUCED LIFE-CYCLE-COSTS NO INTRINSIC SAFE CIRCUITS NEEDED INTEGRAL PID LOOP COMPATIBILITY TO MARKET STANDARDS PREDEFINED SETTINGS PREDEFINED DAMPER CHARACTERISTICS 26 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExReg../ InReg.. Control systems – overview Overview of the new ExReg.. and InReg.. control systems solution The controllers are subdevided in 2 installation and 4 application areas. The new control systems concept offers especially in Ex-area huge benefits: Installation areas: ExReg- ........................................Modules for Ex-area zone 1, 2, 21, 22 InReg- .........................................Modules for safe area Application areas: ExReg/ InReg-V ..........................0RGXOHVIRUYROXPHIORZFRQWURO&$9 9$9 ExReg/ InReg-V ..........................Modules for pressure and differential pressure control ExReg/ InReg-D ..........................Modules for temperature control ExReg/ InReg-D ..........................Modules for humidity control 1. 2. 3. 4. 5. 7. 8. 9. 10. Usage directly in hazardous areas in zone 1, 2, 21, 22 Can be configured on site in the hazardous location Decentralised control structures Fewer components Reduced Life-Cycle-Costs 1RQHFHVVLW\WRLQVWDOOVDIHW\EDUULHUVRUWRXVHVSHFLDOZLULQJ Integral PID loop 2SWLRQDOLQVWDLQOHVVVWHHO$,6,RUZLWK&0SDLQWLQJ Predefined Settings and damper characteristics Cost effective 9ROXPHIORZ&$9 9$93UHVVXUHǻ3 VAV ExReg-V ǻP 9$9 normal wiring 7HPSHUDWXUH& ExReg-D °C ExReg-D-.., InReg-D-.. Control of temperature in ventilation systems for building management control equipment, for chemical, pharmaceutical, industrial and offshore plants directly in hazardous areas zones 1, 2 JDV DQG GXVW ,Q5HJ' LQ VDIH DUHD To complete the technical solution an additional valve DFWXDWRU W\SH ([0D[&< ([0D[&<) ZLWK IDLO VDIHVSULQJUHWXUQRU([5XQLVUHTXLUHG Duct sensor normal wiring Room sensor Humidity %rH %rH ExReg-D ExReg-D-.., InReg-D-.. Control of humidity in ventilation systems for building management control equipment, for chemical, pharmaceutical, industrial and offshore plants directly in hazardous areas zones 1, 2 JDV DQG GXVW ,Q5HJ' LQ VDIH DUHD To complete the technical solution an additional valve DFWXDWRU W\SH ([0D[&< ([0D[&<) ZLWK IDLO VDIHVSULQJUHWXUQRU([5XQLVUHTXLUHG Duct sensor normal wiring Safe area ExReg-V-.., InReg-V-.. Control of air flows and pressure in ventilation systems for building management control equipment, for chemical, pharmaceutical, industrial and offshore plants directly in hazardous areas zones 1, JDV DQG GXVW ,Q5HJ9 LQ VDIH DUHD To complete the technical solution on a ventilation GDPSHU ZLWK RULILFH SODWH DQG NQRZQ VKLHOGN IDFWRU DQ DGGLWLRQDO DFWXDWRU W\SH ([0D[&< RU ([0D[&<)ZLWKIDLOVDIHVSULQJUHWXUQLVUHTXLUHG Room sensor Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 27 Price list 2014 Technical short info 2014 ExReg-V300-../ InReg-V300-..9ROXPHIORZDQGSUHVVXUHFRQWUROOHU&$9 9$9 Safe area Ex area 9$9DSSOLFDWLRQVLQDW\SLFDO+9$&V\VWHP Restrictor Air damper rP M VAV PLC-System Controller ExReg-V300-.. Differential pressure «3D9$9 28 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExReg-V300-../ InReg-V300-..9ROXPHIORZDQGSUHVVXUHFRQWUROOHU&$9 9$9 )HDWXUHVRI([5HJ9,Q5HJ9 Explosion proof Industrial ExReg-V300-.. InReg-V300-.. 127H[SORVLRQSURRI and only for use in safe area ,3 =RQH Gas + Dust certified according ATEX, IECEx, GOST-R Description Basics for all ..Reg-V300-.. controller Compact controller for use in hazardous areas zone 1, 2, 21, 22 for control/regulation of air/gas flows and pressure in ventilation systems. Suitable actuator ..Max-...-CY or ..Max-...&<)ZLWKIDLOVDIHVSULQJUHWXUQDYDLODEOH separately. 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG Adjustable “k-factor” 0HDVXUHPHQWUDQJH«3D 9$&'& Switch-on delay 3 seconds Air volume monitoring PID controller Programmable w/o additional tools Alarm with alarm delay function /&'EDFNOLJKWZKLFKFDQEHVZLWFKHGRII $OXPLQLXPKRXVLQJSURWHFWLRQ,3 ,QWHJUDWHGWHUPLQDOER[([5HJZLWK³([H´ Optional “C5-M” or stainless steel edition +î:î' îîPP Delivery: Electric volume flow /pressure controller ZLWKLQWHJUDWHGWHUPLQDOER[([5HJZLWK ³([H´WDSSLQJVFUHZVVKRUWFLUFXLWWXEH ExReg-V300-.. Volume flow and pressure controller for zone 1, 2, 21, 22 Type Sensor Supply Meas. range Connection/ Interface (analogue) Installation ExReg-V300-A 'LIIHUHQWLDOSUHVVXUH 9$&'& «3D îDFWXDWRUîVHWSRLQWîDFWXDOYDOXHîSRVLWLRQDFWXDWRU ]RQH ExReg-V300-B 'LIIHUHQWLDOSUHVVXUH 9$&'& «3D îDFWXDWRU56FRPPXQLFDWLRQ ]RQH InReg-V300-.. Volume flow and pressure controller for safe area Type Sensor Supply Meas. range Connection/ Interface (analogue) Installation InReg-V300-A 'LIIHUHQWLDOSUHVVXUH 9$&'& «3D îDFWXDWRUîVHWSRLQWîDFWXDOYDOXHîSRVLWLRQDFWXDWRU VDIHDUHD InReg-V300-B 'LIIHUHQWLDOSUHVVXUH 9$&'& «3D îDFWXDWRU56FRPPXQLFDWLRQ VDIHDUHD Actuators for ..Reg-V300-.. controller Type Torque Running time 90° Spring return Control mode ExMax- 5.10-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK([5HJ9 6 ExMax-15.30-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK([5HJ9 6 ExMax- 5.10-CYF 1P1P ExMax-15- CYF 1P Feedback Features Size VHF aVHF P$ «9'& FRPELQDWLRQZLWK([5HJ9 6 VHF aVHF P$ «9'& FRPELQDWLRQZLWK([5HJ9 6 InMax- 5.10-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ9 6 InMax- 15.30-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ9 6 InMax- 5.10-CYF 1P1P InMax- 15- CYF 1P VHF aVHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ9 6 VHF aVHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ9 6 Accessories Type Technical data MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Kit 2 ,QFOXGHVPHWHUSUHVVXUHKRVHLQQHUGLDPHWHUPPDQGSODVWLFILWWLQJV Special options and offshore kits see page 50 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 29 Price list 2014 Technical short info 2014 ExReg-D-../ InReg-D-..7HPSHUDWXUH& KXPLGLW\U+FRQWUROOHU 7HPSHUDWXUHDQGKXPLGLW\DSSOLFDWLRQVLQDW\SLFDO+9$&V\VWHP Heater Humidifier + %rH Safe area Ex area °C M M °C PLC-System %rH PLC-System Controller ExReg-D-.. Temperature/Humidity í&«& «U+ 30 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExReg-D-../ InReg-D-..7HPSHUDWXUH& KXPLGLW\U+FRQWUROOHU Explosion proof Industrial ExReg-D-.. InReg-D-.. 127H[SORVLRQSURRI and only for use in safe area ,3 =RQH Gas + Dust certified according Features ExReg-D-.., InReg-D-.. ATEX, IECEx, GOST-R Description Basics for all ..Reg-D-.. controller Compact temperature or humidity controller for use in hazardous areas zone 1, 2, 21, 22. Suitable actuator ..Max-...-CY, ..Max-...-CYF ZLWKIDLOVDIHVSULQJUHWXUQRU([5XQ available separately. 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 0HDVUDQJHí«& «U+ 9$&'& Switch-on delay 3 seconds PID controller Programmable w/o additional tools Alarm with alarm delay function /&'EDFNOLJKWZKLFKFDQEH VZLWFKHGRII $OXPLQLXPKRXVLQJSURWHFWLRQ,3 ,QWHJUDWHGWHUPLQDOER[([5HJZLWK³([H´ Optional “C5-M” or stainless steel edition +î:î' îîPP Delivery: Electric temperature or humidity controller ZLWKLQWHJUDWHGWHUPLQDOER[([5HJZLWK ³([H´DQGFRQQHFWLRQIRU([3UR& InPro-C.. sensor probe, 3 tapping screws ExReg-D-.. Temperature/ humidity controller for zone 1, 2, 21, 22 Type Sensor Supply Connection/ Interface (analogue) Installation ExReg-D-A* ([3UR& 9$&'& í«& «U+ Meas. range îDFWXDWRUîVHWSRLQWîDFWXDOYDOXHîSRVLWLRQDFWXDWRU ]RQH ExReg-D-B* ([3UR& 9$&'& í«& «U+ îDFWXDWRU56FRPPXQLFDWLRQ ]RQH *Availability in second quarter. InReg-D-.. Temperature/ humidity controller for safe area Type Sensor Supply Connection/ Interface (analogue) Installation InReg-D-A* ,Q3UR& 9$&'& í«& «U+ Meas. range îDFWXDWRUîVHWSRLQWîDFWXDOYDOXHîSRVLWLRQDFWXDWRU VDIHDUHD InReg-D-B* ,Q3UR& 9$&'& í«& «U+ îDFWXDWRU56FRPPXQLFDWLRQ VDIHDUHD *Availability in second quarter. Actuators for ..Reg-D.. controller Type Torque Running time 90° Spring return Control mode ExMax- 5.10-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK([5HJ' 6 ExMax-15.30-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK([5HJ' 6 ExMax- 5.10-CYF 1P1P ExMax-15- CYF 1P Feedback Features Size VHF aVHF P$ «9'& FRPELQDWLRQZLWK([5HJ' 6 VHF aVHF P$ «9'& FRPELQDWLRQZLWK([5HJ' 6 InMax- 5.10-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ' 6 InMax- 15.30-CY 1P1P VHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ' 6 InMax- 5.10-CYF 1P1P InMax- 15- CYF 1P VHF aVHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ' 6 VHF aVHF P$ «9'& FRPELQDWLRQZLWK,Q5HJ' 6 For suitable ..Run valve actuators see page 20 Sensor probes for ..Reg-D.. controller Type Technical data ExPro-CT.. Temperature sensor probe for connection on ExReg-D-.. controller, installation in zone 1, 2, 21, 22 ExPro-CF.. Humidity sensor probe for connection on ExReg-D-.. controller, installation in zone 1, 2, 21, 22 InPro- CT.. Temperature sensor probe for connection on InReg-D-.. controller, installation in safe area InPro- CF.. Humidity sensor probe for connection on InReg-D-.. controller, installation in safe area &RPELVHQVRUSUREHVQRWDSSOLFDEOH For more details about ExPro-C.. /InPro-C.. see page 37 Accessories Type Technical data MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 31 Price list 2014 Technical short info 2014 Introducing ExCos – Modulating sensor series for explosion proof areas! Differential pressure, temperature and humidity control applications ... HAZARDOUS LOCATIONS ZONE 1, 2, 21, 22 NO TRANSDUCER IN PANEL NEEDED NO INTRINSIC SAFE CIRCUITS NEEDED EASY INSTALLATION EASY PARAMETERISATION REDUCED INSTALLATION COST ACTUAL VALUE INDICATION STAINLESS STEEL SOLUTION 32 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Table of contents Product series Modulating sensors for temperature, humidity, pressure/ differential pressure Overview modulating sensors ([&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3D 5HG&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3D ,Q&RV3 GLIIHUHQWLDOSUHVVXUH9$9VHQVRUV « 3DQRW([ ([&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU([3UR&«VHQVRUV 5HG&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU([3UR&«VHQVRUV ,Q&RV' WHPSHUDWXUHDQGKXPLGLW\WUDQVGXFHUIRU,Q3UR&«VHQVRUVQRW([ ([3UR&« WHPSHUDWXUHDQGKXPLGLW\VHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPV ,Q3UR&« WHPSHUDWXUHDQGKXPLGLW\VHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPVQRW([ ExCos-A transducer for passive, potential free, modulating ExSens sensors RedCos-A transducer for passive, potential free, modulating ExSens sensors ,Q&RV$ WUDQVGXFHUIRUSDVVLYHSRWHQWLDOIUHHPRGXODWLQJVHQVRUVQRW([ ExLine transducer EXL-IMU-1 for passive, potential free, modulating ExSens sensors ExSens modulating, passive temperature- /humidity- /pressure sensors Special options for sensors Overview special options for sensors Overview heating system ExPolar for sensors ([3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQ([DUHDVGRZQWRí& ,Q3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQVDIHDUHDGRZQWRí&QRW([ Installation areas in zone Page 32-34 38 38 39 39 Gas 0 Dust 20 z z z z z z z 50 51 Gas 1 Dust 21 Gas 2 Dust 22 z z z z z z z z z z z z z z z z z z z z z z z z z SA* z z z z z z *SA = Safe area z RQUHTXHVW www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 33 Price list 2014 Technical short info 2014 ExCos../ RedCos../ InCos.. Sensors – Overview The new ExCos..., RedCos and InCos Sensor-Technology The sensors are subdevided in 3 installation- and 3 application areas. The sensor concept offers especially in Ex-area huge benefits: Installation areas: ExCos- ........................................Sensors for Ex-area zone 1, 2, 21, 22 RedCos- .....................................Sensors for Ex-area zone 2, 22 InCos- .........................................Sensors for safe area 1. 2. 3. 4. 5. 7. 8. 9. Application areas: Ex/ Red/ InCos-P ........................sensors for pressure and differential pressure Ex/ Red/ InCos-D + ..Pro-C ........active sensor-heads for temperature and /or humidity Ex/ Red/ InCos-A + ..Sens .........passive sensors for temperature, humidity and potentiometer 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHGEHWZHHQWKHFRQWUROSDQHODQGWKHVHQVRU 1RLQWULQVLFDOO\VDIHFLUFXLWQHFHVVDU\LQVLGHWKHFRQWUROSDQHO 1RWUDQVGXFHUQHHGHGLQWKHHOHFWULFDOFRQWUROSDQHO Reduced installation cost Easy installation Easy parameterisation Cost savings for electrical components Actual value indication 2SWLRQDOLQVWDLQOHVVVWHHO$,6,RUZLWK&0SDLQWLQJ 3UHVVXUH'LIIHUHQWLDO3UHVVXUH9$9±PRGXODWLQJDFWLYH Ǽ3 ExCos-P ǻ3 ExCos-P.., RedCos-P.., InCos-P.. Sensors Transducers with integrated differential-pressure sensor for direct connection of the air-hoses. ,3 DOXPLQLXP KRXVLQJ ZLWK LQWHJUDWHG WHUPLQDO box. Measuring range parametrizable on site. 2XWSXWV«99'&«P$,QWHJUDWHGDFWXDO value indication, illuminated. normal wiring Temperature and/or Humidity – modulating, active °C ExCos-D %rH + ExPro-C.. ExCos-D.., RedCos-D.., InCos-D.. Transducer + ExPro-C.., InPro-C.. sensor probe Duct sensor normal wiring Room sensor Temperature and/or Humidity, Potentiometer – modulating, passive °C ExCos-A %rH + ExSens Ex-i wiring LQWULQVLFDOO\ VDIH normal wiring Temperature, Humidity, Potentiometer – modulating, passive °C EXL-IMU-1 %rH + ExSens Transducer for the installation of an ExPro-C.. or ,Q3UR& ZLWK ,Q&RV' IRU WHPSHUDWXUH & DQG RU KXPLGLW\ LQ ,3 DOXPLQLXP KRXVLQJ ZLWK integrated terminal box. Measuring range parameWUL]DEOH RQ VLWH 2XWSXWV «9 9'&« P$ Integrated actual value indication, illuminated. ExCos-A.., RedCos-A.., InCos-A.. Transducer + ExSens sensor Transducer for a connection of an passive, modulaWLQJ([6HQVVHQVRUW\SH3W1L«N RYHU([LHOHFWULFDOFRQGXLW,3DOXPLQLXPKRXVLQJ with integrated terminal box. Measuring range paraPHWUL]DEOHRQVLWH2XWSXWV«99'&«P$ Integrated actual value indication, illuminated. EXL-IMU-1 transducer + ExSens sensor Transducer for a connection of an passive, modulaWLQJ([6HQVVHQVRUW\SH3W1L«N over Ex-i electrical conduit. Installation in control ER[RQWR',1UDLO0HDVXULQJUDQJHSDUDPHWUL]DEOH RQVLWH2XWSXWV«99'& «P$,QWHJUDWHG actual value indication. Ex-i wiring LQWULQVLFDOO\VDIH normal wiring Safe area 34 Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExCos-P/ RedCos-P/ InCos-P Differential pressure sensors Explosion proof ExCos-P… =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ Industrial RedCos-P… =RQH Gas + Dust certified according ATEX, *2675571&6$ InCos-P… 127([SORVLRQSURRI and only for use in safe area ,3 Features of ExCos-P, RedCos-P, InCos-P Description Basics for all …Cos-P sensors ExCos-P, RedCos-P and InCos-P are presVXUHVHQVRUVIRU+9$&V\VWHPVHJIRU differential pressure control. 9$9FRQWUROPXVWEHWHVWHGE\WKH PDQXIDFWXUHUHURI9$9GDPSHUVLQDFFZLWK diameter, design and characteristics of the air damper. 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$& '&VXSSO\ 2XWSXWV«9'&«P$VHOHFWDEOH Measurement range adjustable $FWXDOYDOXHLQGLFDWLRQZKLFKFDQEH VZLWFKHGRII All parameters can be adjusted on site without additional tools and measurement devices $OXPLQLXPKRXVLQJ,3 Integrated terminal box 'LPHQVLRQV+î:î'îîPP Delivery: 1 sensor with integrated terminal box, 3 tapping screws, short circuit tube ExCos-P... Differential pressure and volume control sensors for zone 1, 2, 21, 22 Type Max. range Overload protected ExCos-P- 100 ± 100 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range Measurement range, min. 20% of max. range 20 Pa Installation module zone 1, 2, 21, 22 ExCos-P- 250 ± 250 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 50 Pa zone 1, 2, 21, 22 ExCos-P- 500 ± 500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 100 Pa zone 1, 2, 21, 22 ExCos-P-1250 ± 1.250 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 250 Pa zone 1, 2, 21, 22 ExCos-P-2500 ± 2.500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 500 Pa zone 1, 2, 21, 22 ExCos-P-5000 ± 5.000 Pa up to 75.000 Pa ± Measurement range free adjustable, min. range 1.000 Pa zone 1, 2, 21, 22 ExCos-P-7500 ± 7.500 Pa up to 120.000 Pa ± Measurement range free adjustable, min. range 1.500 Pa zone 1, 2, 21, 22 RedCos-P... Differential pressure and volume control sensors for zone 2, 22 Type Max. range Overload protected RedCos-P- 100 ± 100 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range Measurement range, min. 20% of max. range 20 Pa Installation module RedCos-P- 250 ± 250 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 50 Pa zone 2, 22 RedCos-P- 500 ± 500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 100 Pa zone 2, 22 RedCos-P-1250 ± 1.250 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 250 Pa zone 2, 22 RedCos-P-2500 ± 2.500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 500 Pa zone 2, 22 RedCos-P-5000 ± 5.000 Pa up to 75.000 Pa ± Measurement range free adjustable, min. range 1.000 Pa zone 2, 22 RedCos-P-7500 ± 7.500 Pa up to 120.000 Pa ± Measurement range free adjustable, min. range 1.500 Pa zone 2, 22 zone 2, 22 InCos-P... Differential pressure and volume control sensors for safe area Type Max. range Overload protected InCos-P- 100 ± 100 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range Measurement range, min. 20% of max. range 20 Pa Installation module InCos-P- 250 ± 250 Pa up to 25.000 Pa ± Measurement range free adjustable, min. range 50 Pa safe area InCos-P- 500 ± 500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 100 Pa safe area InCos-P-1250 ± 1.250 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 250 Pa safe area InCos-P-2500 ± 2.500 Pa up to 50.000 Pa ± Measurement range free adjustable, min. range 500 Pa safe area InCos-P-5000 ± 5.000 Pa up to 75.000 Pa ± Measurement range free adjustable, min. range 1.000 Pa safe area InCos-P-7500 ± 7.500 Pa up to 120.000 Pa ± Measurement range free adjustable, min. range 1.500 Pa safe area safe area Accessories and special designs Type Technical data Ex/RedCos-P..-A 9HUVLRQZLWKRQHDGGLWLRQDOLQWULQVLFDOO\VDIHFLUFXLW «P$RXWSXWWRFRQQHFWH[WHUQDODFWXDOYDOXHLQGLFDWRULQ([DUHDVVXUFKDUJH InCos- 9HUVLRQZLWKRQHDGGLWLRQDO «P$RXWSXWWRFRQQHFWH[WHUQDODFWXDOYDOXHLQGLFDWRULQVDIHDUHDVXUFKDUJH P..-A EXC-RIA-16 Intrinsic safe actual value LCD indicator, for use in zone 1, 2, 21, 22, connectable to ExCos-P..-A or RedCos-P..-A sensors NOC-RIA-16 LCD indicator, connectable to InCos-P..-A sensors MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Kit 2 ,QFOXGHVPHWHUSUHVVXUHKRVHLQQHUGLDPHWHUPPDQGSODVWLFILWWLQJV Special options and offshore kits see page 50 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 35 Price list 2014 Technical short info 2014 ExCos-D/ RedCos-D/ InCos-D Temperature/humidity transducer Explosion proof ExCos-D… =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ RedCos-D… =RQH Gas + Dust certified according ATEX, *2675571&6$ Industrial InCos-D… 127([SORVLRQSURRI and only for use in safe area ,3 Features ExCos-D, RedCos-D, InCos-D Description Basics for all …Cos-D sensors ExCos-D, RedCos-D and InCos-D transGXFHUWRJHWKHUZLWK([3UR &«,Q3UR&« digital sensors are for temperature and /or KXPLGLW\PHDVXUHPHQWLQ+9$&V\VWHPV Delivery: 1 transducer with connection for ([3UR&«VHQVRUWDSSLQJVFUHZV Required accessory (additional price): ([3UR&«RU,Q3UR&«VHQVRU Ordering example for 1 temperature duct sensing, 150 mm sensor tube, additional external value indication, sensor in zone 21, indicator in zone 22. Types to order: î([&RV'W\SHDGGLWLRQ«$ ([LWUDQVGXFHU î([3UR&7([LVHQVRU î(;&5,$([LLQGLFDWRU 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$& '&VXSSO\ &RQQHFWRUIRU([3UR&«VHQVRUVIRUURRP or duct mounting 2XWSXWV«9'&«P$VHOHFWDEOH Measurement range adjustable $FWXDOYDOXHLQGLFDWLRQZKLFKFDQEH VZLWFKHGRII All parameters can be adjusted on site without additional tools and measurement devices $OXPLQLXPKRXVLQJ,3 Integrated terminal box 'LPHQVLRQV+î:î'îîPP ExCos-D temperature-/ humidity module for zone 1, 2, 21, 22 Type Technical data Installation module Installation ExPro sensor ExCos-D 0RGXOHWRFRQQHFW([3UR&«VHQVRUIRUWHPSHUWXUHDQG RUKXPLGLW\IRUXVHLQKD]DUGRXVDUHDV ]RQH ]RQH RedCos-D temperature-/ humidity module for zone 2, 22 Type Technical data Installation module Installation ExPro sensor RedCos-D 0RGXOHWRFRQQHFW([3UR&«VHQVRUIRUWHPSHUWXUHDQG RUKXPLGLW\IRUXVHLQKD]DUGRXVDUHDV ]RQH ]RQH InCos-D temperature-/ humidity module for safe area Type Technical data Installation module Installation InPro sensor InCos-D 0RGXOHWRFRQQHFW,Q3UR&«VHQVRUIRUWHPSHUWXUHDQG RUKXPLGLW\IRUXVHLQVDIHDUHD VDIHDUHD VDIHDUHD Accessories and special designs Type Technical data Ex/RedCos-D-A 9HUVLRQZLWKWZRDGGLWLRQDOLQWULQVLFVDIHFLUFXLW «P$RXWSXWVWRFRQQHFWH[WHUQDODFWXDOYDOXHLQGLFDWRULQ([DUHDVVXUFKDUJH InCos- 9HUVLRQZLWKWZRDGGLWLRQDO «P$RXWSXWVWRFRQQHFWH[WHUQDODFWXDOYDOXHLQGLFDWRULQVDIHDUHDVXUFKDUJH D-A EXC-RIA-16 Intrinsic safe actual value LCD indicator, for use in zone 1, 2, 21, 22, connectable to ExCos-D-A or RedCos-D-A sensors NOC-RIA-16 Actual value LCD indicator, for use in safe area, connectable to InCos-D-A sensors MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP VL3 Sensor extension cable 3 m 2XWSXW IRU&2XWSXW IRUU+ Special options and offshore kits see page 50 Example of combinations 36 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExPro -C…/ InPro-C… Digital temperature /humidity sensors Explosion proof Industrial ExPro-C… InPro-C… Only for use with ,Q&RV'«WUDQVGXFHUV NOT for use in ([DUHD =RQH Gas + Dust certified according ATEX, IECEx PTB-certified in acc. with ExCos-D/RedCos-D transducer )HDWXUHV([3UR&«,Q3UR&« Description Basics for all ExPro-C…/ InPro-C… sensors ([3UR&«VHQVRUVDUHXVHGIRUPHDVXUHPHQWVRI temperature and /or humidity in hazardous areas, for exclusiveXVHZLWK([&RV'«5HG&RV'«WUDQVGXFHUV ,Q3UR&«VHQVRUVDUHVXLWDEOHIRUWHPSHUDWXUHDQG RU humidity measurement in safe areas, for exclusive use ZLWK,Q&RV'«WUDQVGXFHUV Delivery: 6HQVRUVIRUFRQQHFWLRQWR([&RV'«5HG&RV'« transducers. Mechanical and electrical adaptation via connector ([3UR&« ,Q3UR&«VHQVRUVFDQEHVFUHZHGWRWKH KRXVLQJRSWLRQDOO\DWWKHEDFNGXFWPHDVXUHPHQW RUERWWRPURRPPHDVXUHPHQW When using humidity-sensors, the contamination and aggressiveness of the medium has to be regarded 1 sensor with connector Example: room-humidity sensor, 50 mm length Type: 1 x ExPro-CF-50 Attention: only in combination with: 1 × ExCos-D or RedCos-D ,Q&RV'E\,Q3UR&«VHQVRUV Sensor probes for ExCos-D and RedCos-D transducer Type Function Range Connectable to Installation area ExPro-CT - 50 7HPSHUDWXUHVHQVRU í«& Sensor length Main use PP 5RRP'XFW ([&RV' 5HG&RV' ]RQH ExPro-CT -100 7HPSHUDWXUHVHQVRU í«& PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CT -150 7HPSHUDWXUHVHQVRU í«& PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CT -200 7HPSHUDWXUHVHQVRU í«& PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CF - 50 +XPLGLW\VHQVRU «U) PP 5RRP'XFW ([&RV' 5HG&RV' ]RQH ExPro-CF -100 +XPLGLW\VHQVRU «U) PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CF -150 +XPLGLW\VHQVRU «U) PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CF -200 +XPLGLW\VHQVRU «U) PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CTF- 50 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 5RRP'XFW ([&RV' 5HG&RV' ]RQH ExPro-CTF-100 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CTF-150 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ([&RV' 5HG&RV' ]RQH ExPro-CTF-200 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ([&RV' 5HG&RV' ]RQH Sensor probes for InCos-D transducer Type Function Range Connectable to Installation area InPro-CT - 50 7HPSHUDWXUHVHQVRU í«& Sensor length Main use PP 5RRP'XFW ,Q&RV' VDIHDUHD InPro-CT -100 7HPSHUDWXUHVHQVRU í«& PP 'XFW ,Q&RV' VDIHDUHD InPro-CT -150 7HPSHUDWXUHVHQVRU í«& PP 'XFW ,Q&RV' VDIHDUHD InPro-CT -200 7HPSHUDWXUHVHQVRU í«& PP 'XFW ,Q&RV' VDIHDUHD InPro-CF - 50 +XPLGLW\VHQVRU «U) PP 5RRP'XFW ,Q&RV' VDIHDUHD InPro-CF -100 +XPLGLW\VHQVRU «U) PP 'XFW ,Q&RV' VDIHDUHD InPro-CF -150 +XPLGLW\VHQVRU «U) PP 'XFW ,Q&RV' VDIHDUHD InPro-CF -200 +XPLGLW\VHQVRU «U) PP 'XFW ,Q&RV' VDIHDUHD InPro-CTF- 50 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 5RRP'XFW ,Q&RV' VDIHDUHD InPro-CTF-100 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ,Q&RV' VDIHDUHD InPro-CTF-150 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ,Q&RV' VDIHDUHD InPro-CTF-200 &RPELQDWLRQWHPSHUDWXUH KXPLGLW\ í«&«U+ PP 'XFW ,Q&RV' VDIHDUHD Accessories Type Technical data Mounting flange for duct-installation, for variable depth of immersion in the air duct MFK TH- VA 3UREHPDGHRIVWDLQOHVVVWHHO9$OHQJWKPP2WKHUOHQJWKVRQUHTXHVW Kit-FA-VA Sinter filter cap for humidity sensor MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 37 Price list 2014 Technical short info 2014 ExCos-A/ RedCos-A/ InCos-A Temperature/humidity transducer Explosion proof ExCos-A… =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ RedCos-A… =RQH Gas + Dust certified according ATEX, *2675571&6$ Industrial InCos-A... 127([SORVLRQSURRI and only for use in safe area ,3 Features of ExCos-A, RedCos-A, InCos-A Basics for all …Cos-A transducer Description ExCos-A, RedCos-A and InCos-A transducer together with modulating ExSens passive sensors are for temperature or KXPLGLW\PHDVXUHPHQWLQ+9$&V\VWHPV Delivery: 1 transducer with connection for modulating, 3 tapping screws Required accessory (additional price): 1 ExSens sensor, see next page Ordering example for measuring of temperature in air duct, with Pt 100 in zone 1. Types to order: î([&RV$([LWUDQVGXFHU î7)5*([LVHQVRU 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$&'&VXSSO\ Connector for 1 ExSens sensor for room or duct mounting 2XWSXWV«9'&«P$VHOHFWDEOH ,QSXW3W3W3W1L1L 1L1L1L6LHPHQV.3 Passive sensors with resistance output «2KP«2KP Measuring range adjustable $FWXDOYDOXHLQGLFDWLRQZKLFKFDQEH VZLWFKHGRII All parameters can be adjusted on site without additional tools and measurement devices $OXPLQLXPKRXVLQJ,3 Integrated terminal box 'LPHQVLRQV+î:î'îîPP ExCos-A Transducer for passive sensors for zone 1, 2, 21, 22 Type Technical data Installation module Installation sensor* ExCos-A Module to connect 1 modulating ExSens sensor for temperture or humidity for use in hazardous areas zone 1, 2, 21, 22 zone 0, 1, 2, 20, 21, 22 LQDFFZLWKFHUWLILFDWLRQRIVHQVRU RedCos-A Transducer for passive sensors for zone 2, 22 Type Technical data Installation module Installation sensor* RedCos-A Module to connect 1 modulating ExSens sensor for temperture or humidity for use in hazardous areas zone 2, 22 zone 0, 1, 2, 20, 21, 22 LQDFFZLWKFHUWLILFDWLRQRIVHQVRU InCos-A Transducer for passive sensors for safe area Type Technical data Installation module Installation sensor InCos-A Module to connect 1 modulating sensor for temperture or humidity for use in safe area 6HQVRUVDOOSDVVLYHVHQVRUVOLNH3W3W1L safe area safe area Accessories and special designs Type Technical data Ex/RedCos-A-A 9HUVLRQZLWKRQHDGGLWLRQDOLQWULQVLFDOO\VDIHFLUFXLW «P$RXWSXWWRFRQQHFWH[WHUQDODFWXDOYDOXHLQGLFDWRULQ([DUHDVVXUFKDUJH InCos- 9HUVLRQZLWKRQHDGGLWLRQDO «P$RXWSXWWRFRQQHFWH[WHUQDOLQGLFDWRULQVDIHDUHDVXUFKDUJH A-A EXC-RIA-16 Intrinsic safe actual value LCD indicator, for use in zone 1, 2, 21, 22, connectable to ExCos-A-A or RedCos-A-A sensors NOC-RIA-16 Actual value LCD indicator, for use in safe area, connectable to InCos-A-A sensors MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 38 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExLine Ex-transducer with Ex-i circuit for zone 0, 1, 2, 20, 21, 22 Explosion proof Features EXL-IMU-1 EXL-IMU-1 EXL-IMU-1 =RQH Gas + Dust Description Basics EXL-IMU-1 EXL-IMU-1 module with intrinsically safe circuit to FKDQJHDSDVVLYHVHQVRUVLJQDOHJ3WLQWR DQDFWLYHP$9'&VLJQDO certified according ATEX Delivery: ([LPRGXOHIRU',1UDLOPRXQWLQJ Accessory (optional): modulating sensors type ExSens Transducer for passive, potential free, modulating sensors series ExSens. 2-3-4-wire connection 9$&'&VXSSO\ 2XWSXW«9'&«P$ ,QSXW3W1L/61L 6LHPHQV.3/)').9).SDVVLYH VHQVRUVZLWKUHVLVWDQFHRXWSXW«2KP «2KP Display for adjustment and actual value indication Module must be installed in the safe area, sensor in the hazardous area EXL-IMU-1 transducer Type Technical data Installation module Installation sensor* EXL-IMU-1 PRGXOHUDLOPRXQWLQJIRUSDVVLYHVHQVRUVHULHV([6HQV VDIHDUHD ]RQH Optional: N1 supply unit ,QSXW«9$&RXWSXW9'&PD[$PD[SFV(;/,08FRQQHFWDEOH1VXSSO\XQLWLVUHTXLUHGRQO\LQFDVHRI«9$&VXSSO\ LQDFFZLWKFHUWLILFDWLRQRIVHQVRU ExSens passive modulating sensors for zone 1, 2, 22 Explosion proof ExSens =RQH Features modulating ExSens passive Gas + Dust certified according ATEX Manufacturer certificate Description Basics for ExSens sensors ExSens sensors for temperature, humidity or pressure measurement in hazardous areas with manufacturer certification in acc. with ATEX 94/9/EC. The sensors are passive and potential free. Sensors for installation in hazardous areas, connected to a relevant transducer, e.g. ExCos-A, RedCos-A or EXL-IMU-1 The transducer changes the passive resistance signal LQWRDQDFLWYH9'& P$VLJQDO Delivery: 1 Sensor Ordering example for 1 room humidity sensor Type to purchase: 1 × FFR-2G Sensors, connectable to ExCos-A, RedCos-A and EXL-IMU-1 transducer Type Function Measuring range Sensor TFR -2G 5RRPWHPSHUDWXUH í«& 3W',1 Connectable to transducers (;/,08([&RV$5HG&RV$ Sensor in zone TFR -2G3D 5RRPWHPSHUDWXUH,3 í«& 3W',1 (;/,08([&RV$5HG&RV$ TFK -2G3D 'XFWWHPSHUDWXUH,3PP í«& 3W',1 (;/,08([&RV$5HG&RV$ TFK -2G3D-400 'XFWWHPSHUDWXUHOHQJWKPP í«& 3W',1 (;/,08([&RV$5HG&RV$ TFT -2G3D 3UREHWHPSHUDWXUH,3PP í«& 3W',1WXELQJ*òƎ0V (;/,08([&RV$5HG&RV$ TFT-V4A-2G3D 3UREHWHPSHUDWXUH,3PP í«& 3W',1WXELQJ*òƎ9$ (;/,08([&RV$5HG&RV$ TFM 0HDQYDOXHWHPSHUDWXUHP í«& 3W',1 (;/,08([&RV$5HG&RV$ -2G-3 TFR-AN -2G3D 5RRPWHPSHUDWXUHGLUHFWFRQWDFW í«& 3W',1 (;/,08([&RV$5HG&RV$ FFR -2G 5RRPKXPLGLW\ «U) «N (;/,08([&RV$5HG&RV$ FFK -2G 'XFWKXPLGLW\ «U) «N (;/,08([&RV$5HG&RV$ TFFR -2G 5RRPFRPELQDWLRQWHPSKXPLGLW\ «U)«& «N3W î(;/,08î([&RV$î5HG&RV$ TFFK -2G 'XFWFRPELQDWLRQWHPSKXPLGLW\ «U)«& «N3W î(;/,08î([&RV$î5HG&RV$ 'LIIHUHQWLDOSUHVVXUH,3 ¨33D [«\ (;/,08 DFK-07 -2G-FP DFK-17 -2G-FP 'LIIHUHQWLDOSUHVVXUH,3 ¨33D [«\ (;/,08 VFK-07 -2G-FP 9ROXPHFRQWURO,3 «PV [«\ (;/,08 3RWHQWLRPHWHU 5HVLVWDQFH «N (;/,08([&RV$5HG&RV$ ExPro-AT-100 'XFWWHPSHUDWXUHOHQJWKPP í«& 3W',1 (;/,08([&RV$5HG&RV$ ExPro-AT-150 'XFWWHPSHUDWXUHOHQJWKPP í«& 3W',1 (;/,08([&RV$5HG&RV$ ExPro-AT-200 'XFWWHPSHUDWXUHOHQJWKPP í«& 3W',1 (;/,08([&RV$5HG&RV$ SGR -2G www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 39 Price list 2014 Technical short info 2014 Introducing ExBin – Binary sensor series for explosion proof areas! Differential pressure, temperature, humidity, fan belt monitoring and frost protection applications ... HAZARDOUS LOCATIONS ZONE 1, 2, 21, 22 NO MODULE IN PANEL NEEDED NO INTRINSIC SAFE CIRCUITS NEEDED EASY INSTALLATION EASY PARAMETERISATION REDUCED INSTALLATION COST ACTUAL VALUE INDICATION STAINLESS STEEL SOLUTION 40 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Table of contents Product series Binary sensors (thermostats, hygrostats, pressostats, fan belt protection, frost protection) Overview binary sensor technology ([%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3D 5HG%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3D ,Q%LQ3 SUHVVXUHGLIIHUHQWLDOSUHVVXUH « 3DQRW([ ([%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« & 5HG%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« & ,Q%LQ)5 IURVWSURWHFWLRQWKHUPRVWDW í« &QRW([ ([%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQ 5HG%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQ ,Q%LQ1 GULYHEHOWPRQLWRULQJ « 8PLQQRW([ ([%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU([3UR%«SUREHVHQVRUV 5HG%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU([3UR%«SUREHVHQVRUV ,Q%LQ' WHPSHUDWXUHDQGKXPLGLW\WKHUPRVWDWIRU,Q3UR%«SUREHVHQVRUVQRW([ ([3UR%« GLJLWDOWKHUPRVWDW K\JURVWDWVHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPV ,Q3UR%« GLJLWDOWKHUPRVWDW K\JURVWDWVHQVRUSUREHVIRURSHUDWLRQLQ+9$&V\VWHPVQRW([ ExBin-A modules for adaptation of 1-5 passive, potential free, binary ExSens sensors RedBin-A modules for adaptation of 1-5 passive, potential free, binary ExSens sensors ,Q%LQ$ PRGXOHVIRUDGDSWDWLRQRISDVVLYHSRWHQWLDOIUHHELQDU\VHQVRUVQRW([ ExLine switching module EXL-IRU-1 for passive, potential free, binary ExSens sensors ExSens binary, passive temperature- /humidity- /pressure sensors Special options for sensors Overview special options for sensors Overview heating system ExPolar for sensors ([3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQ([DUHDVGRZQWRí& ,Q3RODU KHDWLQJV\VWHPIRUVHQVRUV¶XVHLQVDIHDUHDGRZQWRí&QRW([ Installation areas in zone page 40-42 48 48 49 49 gas 0 dust 20 z z z z z z z z z z z 50 51 gas 1 dust 21 gas 2 dust 22 z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z SA* z z z z z z z z *SA = Safe area z RQUHTXHVW www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 41 Price list 2014 Technical short info 2014 ExBin../ RedBin../ InBin.. Binary Sensors – Overview Overview of the ExBin.., RedBin.. and InBin.. sensor technology The binary sensors are subdevided in 3 installation- and 5 application areas. The binary sensor concept offers especially in Ex-area huge benefits: Installation areas: ExBin- ....................................Sensors for Explosion proof zones 1, 2, 21, 22 RedBin- .................................Sensors for Explosion proof zones 2, 22 InBin- .....................................6HQVRUVIRUVDIHDUHD,3 1. 2. 3. 4. 5. 7. 8. 9. Application areas: Ex/ Red/ InBin-P ....................sensors for pressure and differential pressure monitoring Ex/ Red/ InBin-FR .................sensors for frost protection monitoring Ex/ Red/ InBin-N ....................sensors for drive belt monitoring Ex/ Red/ InBin-D + ..Pro-B ....active probe sensors for temperature and/or humidity monitoring Ex/ Red/ InBin-A + ..Sens ..... passive probe sensors for temperature, humidity, pressure monitoring 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHGEHWZHHQWKHFRQWUROSDQHODQGWKHVHQVRU 1RLQWULQVLFDOO\VDIHFLUFXLWQHFHVVDU\LQVLGHWKHFRQWUROSDQHO 1RVZLWFKLQJPRGXOHQHHGHGLQWKHHOHFWULFDOFRQWUROSDQHO Reduced installation cost Easy installation Easy parameterisation 1- and 2-stage versions available Actual value indication 2SWLRQDOLQVWDLQOHVVVWHHO$,6,RUZLWK&0SDLQWLQJ 3UHVVXUHGLIIHUHQWLDOSUHVVXUH)LOWHU )DQEHOWPRQLWRULQJ±ELQDU\DFWLYH Ǽ3 ExBin-P ǻ3 normal wiring Frost protection thermostats – binary, active °C Frost protection thermostat mechanically adjustaEOHDQGVZLWFKLQJ6HWWLQJUDQJHí«&RU PFDSLOODU\DVVHQVRUZLWKDUHVROXWLRQRIFP effective range. Switching status display with LED. ,3 $OXPLQLXP GLHFDVW KRXVLQJ ZLWK LQWHJUDWHG terminal box. Output 1 potential-free make contact. Drive belt monitoring via speed control – binary, active ExBin-N.., RedBin-N.., InBin-N.. Binary, contactless fan belt monitoring by inductive VSHHGFRQWURO0HDVXUHPHQWUDQJH«PLQ-1, 6HWWLQJUDQJH«PLQ-1, incl. time switch relais DQG LQGLFDWLRQ RI DFWXDO YDOXH ,3$OXPLQLXP GLH cast housing with integrated terminal box. Output 1 potential-free make contact. 2-stage version available optional. ExBin-N normal wiring Thermostats, hygrostats – binary, active °C ExBin-D %rH + ExPro-B.. ExBin-D.., RedBin-D.., InBin-D.. + ExPro-B.. respectively InPro-B... Sensor probes Duct sensor normal wiring Room sensor 1-, 2- or 5-channel Ex-switching module for passive, binary sensors °C ExBin-A %rH + ExSens Ǽ3 Ex-i wiring LQWULQVLFDOO\VDIH normal wiring Temperature, humidity, differential pressure – binary, passive °C EXL-IRU-1 %rH + ExSens Ǽ3 Safe area Thermostats and/or hygrostats for connection of one ExPro-B.. respectively InPro-B.. sensor probe. Operating range adjustable. Indication of actual vaOXH,3$OXPLQLXPGLHFDVWKRXVLQJZLWKLQWHJUDWHG terminal box. Output 1 potential-free make contact. 2-stage version optionally available. ExBin-A1/ A2/ A5, RedBin-A1/ A2/ A5 + ExSens sensors binary 1-, 2- or 5-channel Ex-switching module for connection of max. 5 passive, potential-free binary sensors. 6ZLWFKLQJVWDWXVGLVSOD\ZLWK/(',3$OXPLQLXP die-cast housing with integrated terminal box. Output depending on type 1-5 make contacts with collective supply unit. EXL-IRU-1 switching module + ExSens sensor Ex-switching module for connection of one passive, binary ExSens sensor, such as differential pressure switch, frost protection thermostat or hygrostat through intrinsically safe electrical conduit. ,QVWDOODWLRQ LQ FRQWURO ER[ RQWR ',1UDLO 2XWSXW LV potential-free. Ex-i wiring LQWULQVLFDOO\VDIH normal wiring 42 Binary pressure/differential pressure auxiliary VZLWFK « 3D IRU GLUHFW FRQQHFWLRQ RI DLU KRVHV ,3 DOXPLQLXP GLHFDVW KRXVLQJ ZLWK integrated terminal box. Set points adjustable on site, output 1 potential-free make contact. Integrated indication of actual value, illuminated. 2-stage version optionally available. ExBin-FR.., RedBin-FR.., InBin-FR.. ExBin-FR normal wiring Umin ExBin-P.., RedBin-P.., InBin-P.. Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExBin-P/ RedBin-P/ InBin-P Pressure/differential pressure switch, binary Industrial Explosion proof ExBin-P... =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ RedBin-P... =RQH Gas + Dust certified according ATEX, *2675571&6$ InBin-P... 127 Explosion proof and only for use in safe area ,3 Features of ExBin-P, RedBin-P, InBin-P Description Basics for all …Bin-P sensors ExBin-P, RedBin-P and InBin-P are presVXUHVZLWFKHVIRU+9$&V\VWHPVHJIRU differential pressure control for filter- or fan belt monitoring. ..Bin-P-100 pressure switch allows an achievement of new applications with a smaller differential pressure range. Additionally the ..Bin-P-100 has an adjustable switch activation delay contact for applications which require a time-delayed fault indication, for example short opening of doors in clean room environment. Delivery: 1 Pressure switch with integrated terminal box, 3 tapping screws 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$& '&VXSSO\ 1-channel: 1 potential-free contact FKDQQHORSWLRQDOSRWHQWLDOIUHH contacts Switch-point is digitally adjustable ,QGLFDWLRQRIDFWXDOYDOXHFDQEHVZLWFKHGRII Switching status display over LED All parameters can be adjusted on site without additional tools and measurement devices $OXPLQLXPKRXVLQJ,3ZLWKLQWHJUDWHG terminal box ..Bin-P-100 with switch activation delay, DGMXVWDEOHIURP«V 'LPHQVLRQV+î:î'îîPP ExBin-P... Differential pressure switch for zone 1, 2, 21, 22 Type Measurement range Safe overload Setting range Special feature ExBin-P- 100 ExBin-P- 500 ExBin-P- 500-2 ExBin-P-5000 ExBin-P-5000-2 «3D «3D «3D «3D «3D XSWR3D XSWR3D XSWR3D XSWR3D XSWR3D VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH DGMXVWDEOHVZLWFKDFWLYDWLRQGHOD\«V Installation module ]RQH ]RQH ]RQH ]RQH ]RQH RedBin-P... Differential pressure switch for zone 2, 22 Type Measurement range Safe overload Setting range Special feature RedBin-P- 100 RedBin-P- 500 RedBin-P- 500-2 RedBin-P-5000 RedBin-P-5000-2 «3D «3D «3D «3D «3D XSWR3D XSWR3D XSWR3D XSWR3D XSWR3D VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH DGMXVWDEOHVZLWFKDFWLYDWLRQGHOD\«V Installation module ]RQH ]RQH ]RQH ]RQH ]RQH InBin-P... Differential pressure switch for safe area Type Measurement range Safe overload Setting range Special feature InBin-P- 100 InBin-P- 500 InBin-P- 500-2 InBin-P-5000 InBin-P-5000-2 «3D «3D «3D «3D «3D XSWR3D XSWR3D XSWR3D XSWR3D XSWR3D VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH VWDJHDGMXVWDEOHVZLWFKSRLQWLQPHDVUDQJH DGMXVWDEOHVZLWFKDFWLYDWLRQGHOD\«V Installation module VDIHDUHD VDIHDUHD VDIHDUHD VDIHDUHD VDIHDUHD Accessories Type Technical data Kit 2 MKR ,QFOXGHVPHWHUSUHVVXUHKRVHLQQHUGLDPHWHUPPDQGSODVWLFILWWLQJV 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 3UHVVXUHGLIIHUHQWLDOSUHVVXUH)LOWHU )DQEHOWPRQLWRULQJ±ELQDU\DFWLYH ǻ3 normal wiring Safe area Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 43 Price list 2014 Technical short info 2014 ExBin-FR/ RedBin-FR/ InBin-FR Frost protection thermostats Explosion proof ExBin-FR... =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ Industrial RedBin-FR... =RQH Gas + Dust certified according ATEX, *2675571&6$ InBin-FR... 127([SORVLRQSURRI and only for use in safe area ,3 Features ExBin-FR, RedBin-FR, InBin-FR Description Basics for all …Bin-FR sensors ExBin-FR, RedBin-FR and InBin-FR are IURVWSURWHFWLRQWKHUPRVWDWVIRU+9$& systems, e.g. for frost protection monitoring of heating register s/heat exchangers. 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$&'&VXSSO\ Temperature sensoring by capillary with PRUPOHQJWKGHSHQGLQJRQW\SH 0LQUHDFWLRQOHQJWKRIFDSLOODU\aFP 1 potential-free contact Switch-point is mechanically adjustable Switching status display with LED $OXPLQLXPKRXVLQJ,3ZLWKLQWHJUDWHG terminal box 'LPHQVLRQV+î:î'îîPP Delivery: 1 Frost protection thermostat with integraWHGWHUPLQDOER[ZLWKPRUPFDSLOODU\ GHSHQGLQJRQW\SHWDSSLQJVFUHZV Recommended accessory: IRU%LQ)5.LW IRU%LQ)5.LW ExBin-FR... frost protection thermostats for zone 1, 2, 21, 22 Type Capillary Temperature range Setting range Installation module ExBin-FR-3 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH ]RQH ExBin-FR-6 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH ]RQH RedBin-FR... frost protection thermostats for zone 2, 22 Type Capillary Temperature range Setting range Installation module RedBin-FR-3 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH ]RQH RedBin-FR-6 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH ]RQH InBin-FR... frost protection thermostats for safe area Type Capillary Temperature range Setting range Installation module InBin-FR-3 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH VDIHDUHD InBin-FR-6 P í& VWDJHDGMXVWDEOHVZLWFKSRLQWLQWHPSHUDWXUHUDQJH VDIHDUHD Accessories Type Technical data Kit 1.3 Capillary duct, assembly cramp and 4 assembly brackets for frost protection thermostat ..Bin-FR-3 Kit 1.6 &DSLOODU\GXFWDVVHPEO\FUDPSDQGDVVHPEO\EUDFNHWVIRUIURVWSURWHFWLRQWKHUPRVWDW%LQ)5 MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 Frost protection thermostat – binary, active normal wiring Safe area 44 Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExBin-N/ RedBin-N/ InBin-N Fan belt monitoring via speed control Explosion proof ExBin-N... =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ Industrial RedBin-N... =RQH Gas + Dust certified according ATEX, *2675571&6$ InBin-N... 127([SORVLRQSURRI and only for use in safe area ,3 )HDWXUHVRI([%LQ15HG%LQ1,Q%LQ1 Description Basics for all …Bin-N sensors ([%LQ15HG%LQ1DQG,Q%LQ1DUHIDQEHOW PRQLWRULQJPRGXOHVIRU+9$&V\VWHPVYLD speed control of fan drive shaft. 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$&'&VXSSO\ Measurement of number of revolutions in min-1 Switch-point in min-1 is digitally adjustable Integrated, adjustable time switch relais 1-channel: 1 potential-free contact FKDQQHORSWLRQDOSRWHQWLDOIUHHFRQWDFWV Display with indication of actual value Switching status display with LED $OXPLQLXPKRXVLQJ,3ZLWKLQWHJUDWHG terminal box 'LPHQVLRQV+î:î'îîPP 1DPXUWUDQVGXFHULQFOXGHGLQGHOLYHU\ Delivery: 1 Fan belt monitoring modul with integrated terminal box and provided, directly mountDEOH1DPXUWUDQVGXFHUWDSSLQJVFUHZV Recommended accessory: Dependend on air power and dimensions of ventilator /propeller a mounting console is required. The indicated values in m³ /h are empirical values – they can vary depending on the construction of ventilator /propeller. ExBin-N.. fan belt monitoring modules via speed control for zone 1, 2, 21, 22 Type Sensor Speed control range Setting range Installation module ExBin-N 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 zone 1, 2, 21, 22 ExBin-N-2 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 zone 1, 2, 21, 22 RedBin-N.. fan belt monitoring modules via speed control for zone 2, 22 Type Sensor Speed control range Setting range Installation module RedBin-N 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 zone 2, 22 RedBin-N-2 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 zone 2, 22 InBin-N.. fan belt monitoring modules via speed control for safe area Type Sensor Speed control range Setting range Installation module InBin-N 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 safe area InBin-N-2 1DPXUWUDQVGXFHULQGXFWLYH',1 PLQ-1 VWDJHDGMXVWDEOHVZLWFKSRLQWIURP«PLQ-1 safe area Accessories Type Technical data Kit 3 0RXQWLQJVHWIRU1DPXUWUDQVGXFHURQWRYHQWLODWRUV SURSHOOHUVup to approx. 20.000 m³ /h Kit 4 0RXQWLQJVHWIRU1DPXUWUDQVGXFHURQWRYHQWLODWRUV SURSHOOHUVover approx. 20.000 m³ /h MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 Drive belt monitoring via speed control – binary, activ 5 mm normal wiring Safe area Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 45 Price list 2014 Technical short info 2014 ExBin-D/ RedBin-D/ InBin-D Thermostats, hygrostats Explosion proof ExBin-D... =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ RedBin-D... =RQH Gas + Dust certified according ATEX, *2675571&6$ Industrial InBin-D... 127([SORVLRQSURRI and only for use in safe area ,3 Features of ExBin-D, RedBin-D, InBin-D Description ExBin-D, RedBin-D and InBin-D modules DUHXVHGWRJHWKHUZLWK([3UR%« ,Q3UR %«VHQVRUSUREHVDVWKHUPRVWDWVRU K\JURVWDWVLQ+9$&V\VWHPV Delivery: 1 Ex/Red/InBin.. module with VRFNHWIRU([3UR %« ,Q3UR%«VHQVRU 3 tapping screws Required accessory (additional price): ([3UR%«RU,Q3UR%«VHQVRU Ordering example for one thermostat in an air duct, 150 mm sensor length, with sensor in Ex zone 21. Types to order: 1 × ExBin-D î([3UR%7([LVHQVRUSUREH Basics for all …Bin-D sensors 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG 9$&'&VXSSO\ 6RFNHWIRU([3UR%«VHQVRU Selectable on site if used for room or duct application 6ZLWFKSRLQWIRU&DQGU+VHSDUDWHO\DG MXVWDEOHGHSHQGHQGRQVHQVRUSUREHW\SH FKDQQHOSRWIUHHFRQWDFWVî&îU+ FKDQQHOSRWIUHHFRQWDFWVî&îU+ Display with indication of actual value Switching status display with LED $OXPLQLXPKRXVLQJ,3ZLWKLQWHJUDWHG terminal box 'LPHQVLRQV+î:î'îîPP ExBin-D thermostats and/ or hygrostats, dependend on sensor probe type ExPro-B… for zone 1, 2, 21, 22 Type Technical data Installation module Installation ExPro-B.. sensor ExBin-D 0RGXOHIRUFRQQHFWLRQRIRQH([3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH ]RQH ]RQH ExBin-D-2 0RGXOHIRUFRQQHFWLRQRIRQH([3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH ]RQH ]RQH RedBin-D thermostats and/ or hygrostats, dependend on sensor probe type ExPro-B… for zone 2, 22 Type Technical data Installation module Installation ExPro-B.. sensor RedBin-D 0RGXOHIRUFRQQHFWLRQRIRQH([3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH ]RQH ]RQH RedBin-D-2 0RGXOHIRUFRQQHFWLRQRIRQH([3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH ]RQH ]RQH InBin-D thermostats and/ or hygrostats, dependend on sensor probe type InPro-B… for safe area Type Technical data Installation module Installation InPro-B.. sensor InBin-D 0RGXOHIRUFRQQHFWLRQRIRQH,Q3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH VDIHDUHD VDIHDUHD InBin-D-2 0RGXOHIRUFRQQHFWLRQRIRQH,Q3UR%«VHQVRUDVWKHUPRVWDWDQG RUK\JURVWDWVWDJH VDIHDUHD VDIHDUHD Accessories Type Technical data MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 Example of combinations 46 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExPro-B/ InPro-B Digital thermostat /hygrostat sensor probes Explosion proof Industrial ExPro-B… InPro-B… Only for use with ,Q%LQ'WUDQVGXFHU NOT for use in ([DUHD =RQH Gas + Dust certified according ATEX, IECEx PTB-certified in acc. with ExBin-D/RedBin-D modules Features of ExPro-B.., InPro-B.. Description Basics for all ExPro -B…/ InPro-B… sensors ([3UR%«VHQVRUVDUHXVHGIRUPHDVXUHPHQWVRI temperature and /or humidity in hazardous areas, for exclusiveXVHZLWK([%LQ'«5HG%LQ'«PRGXOHV ,Q3UR%«VHQVRUVDUHVXLWDEOHIRUWHPSHUDWXUHDQG RU humidity measurement in safe areas, for exclusive use ZLWK,Q%LQ'«PRGXOHV Delivery: 1 sensor with connector Example: Type: Attention: room-humidity sensor, 50 mm length 1 × ExPro-BF-50 only in combination with: 1 × ExBin-D or RedBin-D ,Q%LQ'«ZLWK,Q3UR%«VHQVRUV 6HQVRUVIRUFRQQHFWLRQWR([%LQ'«5HG%LQ'« ,Q%LQ'«PRGXOHV$GDSWLRQYLDFRQQHFWRU ([3UR%« ,Q3UR%«VHQVRUVFDQEHRSWLRQDOO\ VFUHZHGWRWKHKRXVLQJDWWKHEDFNGXFWPHDVXUHPHQW RUERWWRPURRPPHDVXUHPHQW When using humidity-sensors, the contamination and aggressiveness of the medium has to be regarded Sensor probes for ExBin-D and RedBin-D modules Type Function Measurement range Sensor length Main use Connectable to Installation area ExPro-BT - 50 7KHUPRVWDW í«& PP 5RRP'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BT -100 7KHUPRVWDW í«& PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BT -150 7KHUPRVWDW í«& PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BT -200 7KHUPRVWDW í«& PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BF - 50 +\JURVWDW «U+ PP 5RRP'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BF -100 +\JURVWDW «U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BF -150 +\JURVWDW «U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BF -200 +\JURVWDW «U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BTF- 50 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 5RRP'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BTF-100 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BTF-150 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH ExPro-BTF-200 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ([%LQ' 5HG%LQ' ]RQH Sensor probes for InBin-D modules Type Function Measurement range Connectable to Installation area InPro-BT - 50 7KHUPRVWDW í«& Sensor length Main use PP 5RRP'XFW ,Q%LQ' VDIHDUHD InPro-BT -100 7KHUPRVWDW í«& PP 'XFW ,Q%LQ' VDIHDUHD InPro-BT -150 7KHUPRVWDW í«& PP 'XFW ,Q%LQ' VDIHDUHD InPro-BT -200 7KHUPRVWDW í«& PP 'XFW ,Q%LQ' VDIHDUHD InPro-BF - 50 +\JURVWDW «U+ PP 5RRP'XFW ,Q%LQ' VDIHDUHD InPro-BF -100 +\JURVWDW «U+ PP 'XFW ,Q%LQ' VDIHDUHD InPro-BF -150 +\JURVWDW «U+ PP 'XFW ,Q%LQ' VDIHDUHD InPro-BF -200 +\JURVWDW «U+ PP 'XFW ,Q%LQ' VDIHDUHD InPro-BTF- 50 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 5RRP'XFW ,Q%LQ' VDIHDUHD InPro-BTF-100 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ,Q%LQ' VDIHDUHD InPro-BTF-150 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ,Q%LQ' VDIHDUHD InPro-BTF-200 &RPELQDWLRQ7KHUPRVWDW+\JURVWDW í«&«U+ PP 'XFW ,Q%LQ' VDIHDUHD Accessories Type Technical data Mounting flange for duct-installation, for variable depth of immersion in the air duct MFK TH- VA 3UREHPDGHRIVWDLQOHVVVWHHO9$OHQJWKPP2WKHUOHQJWKVRQUHTXHVW Kit-FA-VA Sinter filter cap for humidity sensor MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 47 Price list 2014 Technical short info 2014 ExBin-A/ RedBin-A/ InBin-A Switching modules Industrial Explosion proof ExBin-A =RQH Gas + Dust certified according ATEX, IECEx, *2675571.26+$ RedBin-A =RQH Gas + Dust certified according ATEX, *2675571&6$ InBin-A 127([SORVLRQSURRI and only for use in safe area ,3 Features of ExBin-A, RedBin-A, InBin-A Description Basics for all …Bin-A modules ExBin-A, RedBin-A and InBin-A modules are switching modules for direct mounting LQ([DUHDVH[FHSW,Q%LQ$ZLWKRU channels, for connection of 1, 2 or 5 passive potential-free binary sensors, for use in +9$&V\VWHPV 1RDGGLWLRQDOPRGXOHLQWKHSDQHOUHTXLUHG 1RLQWULQVLFDOO\VDIHZLULQJUHTXLUHG Mounting of module directly in Ex area 9$&'&VXSSO\ 1 up to 5 passive, potential-free, binary sensors Sockets for 1 up to 5 ExSens sensors 1 up to 5 contacts with common supply unit 1 or 2 contacts with additional clamp for time switch relais, e.g. for 2 fan belt moni WRULQJDSSOLFDWLRQVWLPHVHF Display with indication of actual value Switching status display with LED $OXPLQLXPKRXVLQJ,3ZLWKLQWHJUDWHG terminal box 'LPHQVLRQV+î:î'îîPP Delivery: 1 module with sockets for 1 up to ([6HQVVHQVRUVGHSHQGHQWRQW\SH 3 tapping screws Accessory (optional): Binary sensors series ExSens, see next page ExBin-A.. Switching modules for 1 up to 5 passive binary sensors for zone 1, 2, 21, 22 Type Technical data Installation module Installation sensor* ExBin-A-1 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRULQ([DUHD ]RQH ]RQH ExBin-A-2 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRUVLQ([DUHD ]RQH ]RQH ExBin-A-5 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRUVLQ([DUHD ]RQH ]RQH LQDFFZLWKFHUWLILFDWLRQRIVHQVRU RedBin-A.. Switching modules for 1 up to 5 passive binary sensors for zone 2, 22 Type Technical data Installation module Installation sensor* RedBin-A-1 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRULQ([DUHD ]RQH ]RQH RedBin-A-2 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRULQ([DUHD ]RQH ]RQH RedBin-A-5 0RGXOHFKDQQHOWRFRQQHFWELQDU\([6HQVVHQVRULQ([DUHD ]RQH ]RQH LQDFFZLWKFHUWLILFDWLRQRIVHQVRU InBin-A.. Switching modules for 1 up to 5 passive binary sensors for safe area Type Technical data Installation module Installation sensor InBin-A-1 0RGXOHFKDQQHOWRFRQQHFWELQDU\VHQVRU VDIHDUHD VDIHDUHD InBin-A-2 0RGXOHFKDQQHOWRFRQQHFWELQDU\VHQVRUV VDIHDUHD VDIHDUHD InBin-A-5 0RGXOHFKDQQHOWRFRQQHFWELQDU\VHQVRUV VDIHDUHD VDIHDUHD Accessories Type Technical data MKR 0RXQWLQJEUDFNHWIRULQVWDOODWLRQRQURXQGDLUGXFWVGLDPHWHUXSWRPP Special options and offshore kits see page 50 1, 2 or 5-channel switching module for passive binary sensors Ex-i wiring LQWULQVLFDOO\VDIH normal wiring Safe area 48 Ex area www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExLine Ex-switching module for potential free, binary signals in zone 0, 1, 2, 20, 21, 22 Explosion proof Features EXL-IRU-1 EXL-IRU-1 EXL-IRU-1 =RQH Gas + Dust Description Basics EXL-IRU-1 EXL-IRU-1 module with intrinsically safe circuit to change a passive potential free binary signal HJFRQWDFWLQWRDFRQWDFWLQWKHVDIHDUHD certified according ATEX Delivery: ([LPRGXOHIRU',1UDLOPRXQWLQJ Accessory (optional): binary sensors type ExSens 9$&'&VXSSO\ Input: passive potential free binary sensor Output: potential free contact in the safe area Integrated time running relais 30...120 sec. 2 LED to show switching position ',1UDLOPRXQWLQJ Module must be installed in the safe area, sensor in the hazardous area EXL-IRU-1 switching module Type Technical data Installation module Installation sensor* EXL-IRU-1 PRGXOHUDLOPRXQWLQJIRUSDVVLYHELQDU\VHQVRUVHULHV([6HQV VDIHDUHD ]RQH Optional: N1 supply unit ,QSXW«9$&RXWSXW9'&PD[$PD[SFV(;/,58FRQQHFWDEOH1VXSSO\XQLWLVUHTXLUHGRQO\LQFDVHRI«9$&VXSSO\ LQDFFZLWKFHUWLILFDWLRQRIVHQVRU ExSens passive binary sensors for zone 1, 2, 22 Explosion proof ExSens =RQH Features ExSens binary, passive Gas + Dust certified according ATEX Manufacturer certificate Description Basics for binary ExSens sensors ExSens binary sensors for temperature, humidity or pressure measurement in hazardous areas with manufacturer certification in acc. with ATEX 94/9/EC. The sensors are passive and potential free. Delivery: 1 Sensor Ordering example for 1 frost protection thermostat Type to purchase: î7%.)5* Sensors for installation in hazardous areas, connected to a switching module type ExBin-A, RedBin-A or EXL-IRU-1 The module changes the passive binary signal into a contact in the safe area Sensor must be installed in the hazardous area, module in the safe area Sensors, connectable to switching modules type ExBin-A, RedBin-A and EXL-IRU-1 Type Function Range Sensor Information Connectable to module type TBR -2G 5RRPWKHUPRVWDW «&. &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ Sensor in zone TBR -2G3D 5RRPWKHUPRVWDW,3 í«&. &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ î&RQWDFWSRV î(;/,58([%LQ$5HG%LQ$ &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ TBR-2 -2G 5RRPWKHUPRVWDWVWDJH «&. TBR-AN-2G 5RRPWHPSHUDWXUHGLUHFWFRQWDFW «&.IL[ TBK -2G 'XFWWKHUPRVWDW,3 «&. &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ TBT -2G 3UREHWKHUPRVWDW,3 «&. &RQWDFWSRV / PP (;/,58([%LQ$5HG%LQ$ TBT-VA -2G 3UREHWKHUPRVWDWZLWK9$VOHHYH «&. &RQWDFWSRV 9$ (;/,58([%LQ$5HG%LQ$ TBK-FR-2G )URVWSURWHFWLRQWKHUPRVWDW,3 í«& &RQWDFWSRV FDSLOODU\P (;/,58([%LQ$5HG%LQ$ FBR -2G 5RRPK\JURVWDW «U+aU+ &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ FBK -2G 'XFWK\JURVWDW «U+aU+ &RQWDFWSRV / PP (;/,58([%LQ$5HG%LQ$ DBK -2G Differential pressure 20-300, 50-500, 100-1.000 Pa Contact, 2-pos EXL-IRU-1, ExBin-A, RedBin-A 1, 2 DBK -2G3D 'LIIHUHQWLDOSUHVVXUH,3 3D &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ WFBK -2G $LUSDGGOH «PVSDGGOH9$ &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ SWBT -2G OLTXLGIORZVZLWFK í«& &RQWDFWSRV (;/,58([%LQ$5HG%LQ$ NBW-K -2G )DQEHOWSURWHFWLRQ,3 XSWRPñK 1DPXUVHQVRUEUDFNHW (;/,58([%LQ$5HG%LQ$ NBW-G -2G )DQEHOWSURWHFWLRQ,3 PRUHWKDQ!PñK 1DPXUVHQVRUEUDFNHW (;/,58([%LQ$5HG%LQ$ Accessories Type Technical data Kit 1 IRUIURVWSURWHFWLRQVHQVRUW\SH7%.)5*3*HQWULHVIRUFDSLOODU\EUDFNHWVVXSSRUWEUDFNHW Kit 2-DBK LQFOXGHVPHWHUSUHVVXUHKRVHLQQHUGLDPHWHUPPSODVWLFILWWLQJV www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 49 Price list 2014 Technical short info 2014 ..VA/ ..CT Special options for sensors – overview Overview of special options of Schischek sensors for use under extreme weather conditions Installation/ Application area: Advantages of special options: Usage in hazardous areas under extreme weather conditions and /or for offshore/ onshore applications. Resistant against corrosive and /or maritime atmosphere Usage under extreme weather conditions Approved for offshore- /onshore applications Robust and thereby extended period of application time of sensors Special options sensors Sensors +RXVLQJPDWHULDOLQVWDLQOHVVVWHHO9$RUDOXPLQLXPKRXVLQJZLWK&0SDLQWLQJ&7IRUXVHXQGHU H[WUHPHZHDWKHUFRQGLWLRQV29$DQG2&7YHUVLRQ for offshore applications. VA Cos/Bin/Reg OVA CT OCT 9$ 29$ normal wiring Safe area CT /OCT Ex area ..Cos/ ..Bin/ ..Reg Special options for sensors )HDWXUHV&RV%LQ5HJ«9$ 29$ &7 2&7 Explosion proof Cos/Bin/Reg-…-..VA/..CT available for all sensors In accordance with type for use in Description Special options 9$YHUVLRQZLWKKRXVLQJPDWHULDOLQVWDLQOHVVVWHHO$,6, VRPHSDUWVQLFNHOSODWHG 29$YHUVLRQDOVRZLWKVWDLQOHVVVWHHOKRXVLQJEXWVXLWable especially for offshore applications. CT version with aluminium housing and C5-M painting, resistant against corrosive and maritime atmosphere, some parts nickel plated. OCT version with painted housing like CT, but suitable especially for offshore applications. Ex area or safe area Delivery: 1 sensor with special option Ordering example: ExCos-P-250-CT Basics ..Cos/ ..Bin/ ..Reg-…-VA/ OVA/ CT/ OCT VA: +RXVLQJPDWHULDOLQVWDLQOHVVVWHHO$,6,VRPHSDUWV nickel plated Resistant against corrosive /maritime atmosphere OVA: %DVLFVOLNH9$EXWRIIHUHGDVRIIVKRUHYHUVLRQZLWK DGGLWLRQDOO\WXEHVIRUFODPSLQJULQJPPLQVWDLQOHVVVWHHO CT: C5-M painted aluminium housing Resistant against corrosive /maritime atmosphere Cable glands brass nickel plated Screws in stainless steel OCT: Basics like CT, but offered as offshore version with M20 cable glands and additionally with tubes for clamping ULQJPPLQVWDLQOHVVVWHHO For general basics see sensor technology. ..Cos/ ..Bin/ ..Reg-.. options Type Description/ Technical data Cos/Bin/Reg-..- VA +RXVLQJPDWHULDOLQVWDLQOHVVVWHHO$,6,VRPHSDUWVQLFNHOSODWHGVXUFKDUJH Cos-P/Bin-P/Reg-V..-OVA Offshore version with seawater resistant stainless steel housing. M20 cable glands nickel-plated, pressure connection tubes and screws in stainless steel VXUFKDUJH Cos/Bin/Reg-..- C5-M painted aluminium housing, resistant against corrosive and /or maritime atmosphere. Cable glands nickel-plated, screws in stainless steel VXUFKDUJH CT Cos-P/Bin-P/Reg-V..-OCT Offshore version with seawater resistant C5-M painted Al-housing. M20 cable glands nickel-plated, pressure connection tubes and screws in stainless steel VXUFKDUJH Kit-S8- &DEOHJODQGVî0îPP([HIRUFDEOHVPPLQEUDVVQLFNHOSODWHGIRUUHSODFHWKHSODVWLFFDEOHJODQGVRI&RV %LQ5HJVHQVRUV CBR Kit-Offs-GL-CBR Cable glands 2 × M20 × 1,5 mm Ex-d in brass nickel plated for armoured cables suitable for ..Cos/..Bin/..Reg sensors Kit-PTC- 3UHVVXUHWXEHFRQQHFWLRQLQVWDLQOHVVVWHHO/IRUPPFODPSILWWLQJV 50 CBR www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 ExPolar Heating system – overview 2YHUYLHZRIQHZKHDWLQJV\VWHPIRUXVHZLWK6FKLVFKHNVHQVRUVGRZQWRí& Installation/ Application area: Advantages of ExPolar: 8VDJHLQKD]DUGRXVDUHDVIRUWHPSHUDWXUHVGRZQWRí& (VSHFLDOO\IRUXVDJHXQGHUKLJKVXE]HURWHPSHUDWXUHVGRZQWRí& 6XLWDEOHIRUDSSOLFDWLRQVZLWKKLJKWHPSHUDWXUHIOXFWXDWLRQVí&XSWR& Usage directly in hazardous locations Adaptable on all Schischek sensors Heating system for sensors ExPolar-..-CBR °C ExPolar-..-CBR Adaptable on Schischek sensors type ExCos-.., ExBin-.., ExReg-... normal wiring Safe area Ex area ExPolar/ InPolar Heating system for ..Cos-.. /Bin-../Reg-.. sensors Explosion proof Industrial ExPolar-…-CBR InPolar-…-CBR =RQH Gas + Dust certified according ATEX, IECEx 127H[SORVLRQSURRI and only for use in safe area ,3 )HDWXUHV3RODU«&%5 Description Controlled heating system for use in sub]HURUHJLRQVGRZQWRí&RUE\KLJK WHPSHUDWXUHIOXFWXDWLRQVIURPí& XSWR& Adaptable on Schischek sensors ..Cos-.., ..Bin-.. or ..Reg-... Delivery: 1 heating system DGDSWDEOH Ordering example: ExPolar-240-CBR Basics ..Polar 9$&'&9$& 40 W í&«& ExPolar for zone 1, 2, 21, 22 InPolar for safe area ExPolar-…-CBR/ InPolar-…-CBR Type Adaptable on ExPolar-…-CBR ([&RV([%LQ([5HJ InPolar- …-CBR ,Q&RV,Q%LQ,Q5HJ Supply voltage Operation temperature Supply Power* í&XSWR& í&XSWR& 9$&'&9$&'&9$&9$& 9$&'&9$&'&9$&9$& : ]RQH : VDIHDUHD *Nominal value Installation area VA option not considered ! www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 51 Price list 2014 Technical short info 2014 ExMag Electric doorholder magnets according ATEX for zone 1, 2, 21, 22 Explosion proof Features ExMag Magnet ExMag Description =RQH Gas + Dust Basics ExMag ExMag doorholder magnets are electric magnets to keep doors open or closed as long as supply voltage is available. certified according ATEX Delivery: 1 magnet Ordering example: 1PDJQHWDQFKRU + Ex-terminal box Type to purchase: î(;0*+ î(;&.6 Electric magnets, silicone free Force in acc. with type 9'&SRZHUVXSSO\ 1 m cable, silicone and halogen free Ex-e terminal box is required for electrical connection The max. AC-ripple must not exceed 20% ExMag magnets Type Force Supply Function Current EXM- 650 1 9'& 0DJQHW P$ Installation in =RQH EXM-1300 1 9'& 0DJQHW P$ =RQH EXM-2000 1 9'& 0DJQHW P$ =RQH Accessories Type Technical data GH-6 $QFKRUIRU(;0 GH-13/20 Anchor for EXM-1300 and EXM-2000 ExBox-3P ([HWHUPLQDOER[,3 EXC-K4/S ([HWHUPLQDOER[,3ZLWKLQWHJUDWHGIXVH EXC-T1 Ex-d push button N1 supply unit ,QSXW«9$&RXWSXW9'&PD[$ ExComp different Ex-components Explosion proof ExComp =RQH LQDFFWRW\SH Gas + Dust certified according ATEX Features ExComp Components Description Different explosion proof products like switches, safety temperature sensors, .... Basics ExComp 1RVSHFLILFLQIRUPDWLRQ Data in acc. with every single product /type Delivery: 1 component Ordering example: 6ZLWFK$SROH Type to purchase: î(;&5 ExComp components Type Application Explosion proof Technical data EXC-R 10/3... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 20/3... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 20/6... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 40/3... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 40/6... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 80/3... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-R 80/6... 6ZLWFK ,,*(([HG,,&7 $9.:SROH EXC-RIA-16 $FWXDOYDOXHLQGLFDWLRQ ,,*(([LD,,&7 P$ORRSSRZHUHG EXC-DS1/VA 6DIHW\WHPSHUDWXUHVHQVRU ,,*(([G,,&7 'XFWPRXQWLQJSRWHQWLDOIUHHFRQWDFWVZLWFKLQJDW&«&&VWHSV 52 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Price list 2014 Technical short info 2014 Table of contents Additional information Product codes/definitions ,QVWDOODWLRQDFFRUGLQJWR$7(;=RQHV\VWHP ,QVWDOODWLRQDFFRUGLQJWR1(&'LYLVLRQV\VWHP1RUWK$PHULFD 9DOYHDXWRPDWLRQ &HUWLILFDWLRQLQIRUPDWLRQ ,QIRUPDWLRQDERXW$7(;(& /DEHOOLQJRIH[SORVLRQSURRIHTXLSPHQWDFFRUGLQJWR$7(; ([SORVLRQSURRILQIRUPDWLRQ ,QIRUPDWLRQDERXW]RQHVH[SORVLRQJURXSVDQGWHPSHUDWXUHFODVVHV ([DSSOLFDWLRQV 6,/³6DIHW\,QWHJULW\/HYHO´ Rotork products 1RWLFHV *HQHUDOFRQGLWLRQV www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl page 54-55 70-73 74-75 h6! 53 Technical short info 2014 Product codes /definitions Description ..Max quarter turn actuators Ex Max - 5.10 - SF S = integrated auxiliary switchesVZLWFKLQJDWDQG F = spring returnJHUPDQZRUGIRUVSULQJLV³)HGHU´ Y = modulatingDFWXDWRU«9'&RU«P$DQGIHHGEDFNVLJQDO BF = fire damper actuatorLQWULQVLFDOO\VDIHLQSXWIRUGLUHFW([3UR77FRQQHFWLRQILUHWULJJHU F1/ F3 = actuator with fast spring returnQXPEHUDIWHUOHWWHU)VKRZVFORVLQJWLPHLQVHFRQGV HJLQRUVHFRQGV C = actuator for direct communication with Ex/InReg controller The numbers show the torque in Nm Two numbers mean that the torque is selectableRQVLWHHJRU1P Max is a rotary (quarter turn) actuator for dampers or rotary valves, such as ball or butterfly valves Ex is for use in zone 1, 2 , 21, 22 Red is for use in zone 2, 22 In is for use in non classified industrial areas Description ..Run valve actuators Red Run - 5.10 - Y Y = modulatingDFWXDWRU«9'&RU«P$DQGIHHGEDFNVLJQDO U = floating controlRQRIISRVDFWXDWRUZLWK«9'&RU«P$IHHGEDFNVLJQDO The numbers show the force in N Two numbers mean that the force is selectableRQVLWHHJRU1 Run is a linear actuatorIRUJOREHVW\OHFRQWUROYDOYHVZLWKDVWURNHEHWZHHQDQGPP Ex is for use in zone 1, 2 , 21, 22 Red is for use in zone 2, 22 In is for use in non classified industrial areas Description ..Cos modulating transducers In Cos - P - 2500 The number shows the measuring range of the differential pressure sensor in ± Pa P = differential pressure sensor D = module for temperature/ humidity for connection of ExPro-C.. sensors A = transducer modul for connection of passive sensors Cos modulatingWUDQVGXFHUZLWKRXWSXW«9RU«P$ Ex is for use in zone 1, 2 , 21, 22 Red is for use in zone 2, 22 In is for use in non classified industrial areas 54 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 Product codes /definitions Description ..Bin binary sensors Ex Bin - P - 500 - 2 The number stands for 2-stage adjustable switch-point in measurement range Without number the sensor is 1-stage adjustable switch-point in measurement range The number shows the max. adjustment range of the differential pressure switch in Pa P = differential pressure switch D = thermostat-/ hygrostat modul for connection of ExPro-B.. sensors FR = frost protection thermostat N = fan belt monitoring via speed control A1 = switching module for connection of one passive switch A2 = switching module for connection of two passive switches A5 = switching module for connection of five passive switches BinVZLWFKLQJPHDVXULQJPRGXOHZLWKRXWSXWDVDSRWHQWLDOIUHHFRQWDFWRSHQHURUFORVHU Ex is for use in zone 1, 2 , 21, 22 Red is for use in zone 2, 22 In is for use in non classified industrial areas Description ..Pro-.. sensors for ..Cos-D or ..Bin-D modules Ex Pro - CTF - 200 The number shows the length of the sensor in mm T = temperature sensor F = humidity sensor TF = combisensor temperature/humidity C = sensor for connection to Ex /Red/InCos-D B = sensor for connection to Ex /Red/InBin-D Pro-.. sensor for connection Ex is for use in zone 1, 2 , 21, 22 In is for use in non classified industrial areas Description ..Reg controller Ex Reg - V - 300 - A A = Type with analog signals for external communication B = Type with busFRPPXQLFDWLRQ56 The number shows the control range of the controller in Pa 9W\SHRQO\ V = volume flow control/pressure control D = temperature/ humidity control Reg controller Ex is for use in zone 1, 2 , 21, 22 In is for use in non classified industrial areas www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 55 Technical short info 2014 ,QVWDOODWLRQDFFRUGLQJWR$7(;=RQHV\VWHP Installation zones Safe area (Ordinary location) Ex area (Hazardous location) Quarter-turn actuator ExMax../ RedMax.. 1 5 4 3 2 1 Valve actuator ExRun../ RedRun.. 1 ([SORVLRQSURRIDFWXDWRU([0D[5HG0D[([5XQ5HG5XQ 4 2 ([WHQVLRQFDEOHDSSUR[LPDWHaP 5 3 56 Supply or control cable 6XSSO\RUFRQWUROFDEOHUHDFKHVLQWRWKHVDIHDUHD« Junction box in increased safety Ex-e technology www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 ,QVWDOODWLRQDFFRUGLQJWR1(&'LYLVLRQV\VWHP1RUWK$PHULFD Installation FM /CSA Div. classes Safe area (Ordinary location) Ex area (Hazardous location) Quarter-turn actuator ExMax../ RedMax..* 1 max. 18" 7 6 2 5 4 3 1 Valve actuator ExRun../ RedRun..* 1 ([SORVLRQSURRIDFWXDWRU([0D[5HG0D[([5XQ5HG5XQ 5 &RQQHFWLQJGHYLFHPD[OHQJWKP 2 (OERZGHYLFH« 6 6HDOILWWLQJIRUKRUL]RQWDORUYHUWLFDOFRQGXLWV« 3 &RQQHFWLQJGHYLFH« 7 &RQQHFWLQJGHYLFHUHDFKHVLQWRWKHVDIHDUHD« 4 &RQGXLWER[« * Variants for North America on request ! www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 57 Technical short info 2014 9DOYHDXWRPDWLRQ Quarter-turn actuators Linear motion actuators ..Max ¼-turn actuator ..Run Linear valve actuator Valve linkage example Valve linkage example Valve example Valve example 58 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 9DOYHDXWRPDWLRQ Schischek valve linkages 210 95 Option 1 80 You make the linkage yourself or source it somewhere else. In that case we would be happy to provide you with all the actuator dimensions necessary to do so. We can even give you STEP files you can import directly into your CAD system. 231 4 M 36 x) (6 118,5 ep de 35 (6 x) V12 37 70 44 74 47,7 -8 18 4, 4 77,6 30 Title ExMax 5.10-Y / 15.30-Y 118,5 60 Dimensions E X P L O S I O N P R O O F . . . . . . . . . . . . . . . . -ASquare Fitting key -C- Flange type DIN 5211 Thread Hole diameter . Vis Project No. Actuator ExMax Drawing No. Rev Sheet 1 / 1 Scale 1:2 -D- -E- -F- -X- -Y- -Z- Flange thickness Distance Torque Nominal size Material 9 9 12 F03 M mm mm mm mm Nm DN 11 14 F04 UNC Zoll Zoll Zoll Zoll lb-in Zoll 14 18 F05 UNF Zoll 17 17 22 F07 VA -V- AISI 316 Increment F10 mm mm F12 Zoll Zoll Other Other Spindle mm U Zoll A Area for screw connecetion Adapter plate A D Price: 27 27 We can quote you a price for a Other linkage forOther mm stem mm any typical valve mounting pattern and Zoll Zoll IRUH[DPSOH,62ZLWKRXWNQRZLQJWKH exact valve dimensions. -U- standard E 22 A3 Height 14 22 . . . 090.0000.A4_Dimensions . 11 Schischek designs and delivers19the linkage 19 . . . Signed Checked Approved Project Schischek GmbH Mühlsteig 45 Gewerbegebiet V D-90579 Langenzenn . . Date V Option 2 -B- Two flat . . . A0 . Rev Description List of parts . Substitute for . Origin . F Order: When you order the linkage however, we need the dimensions of the top plate/mounting pattern as well as the stem shape and dimensions to design the linkage. The cut sheet for your valve will typically Xhave that information. Simply send us the cut sheet and we will do the rest. Y C B Title Customer Project Country ExMax on ball valve E X P L O S I O N P R O O F Actuator type Armature Type Manufacturer . . . . . . . . . . . . . . . . . . Rev Description . . . Date . . . Vis . Substitute for . Origin . List of parts Schischek GmbH Mühlsteig 45 Gewerbegebiet Süd 5 D-90579 Langenzenn Project No. Project Signed Checked Approved . . . Drawing No. . . . Rev 2011.070.E0-USA Scale 1:1.5 Sheet 1 / 1 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl A3 59 Technical short info 2014 Certification with highest protection classes ATEX IECEx SIL ,3,10(752 CSA UL GOST-R 571.26+$ ATEX is a commonly used synonym for the ATEX guidelines of the European Union. The name is derived from the French term ATmosphère EXplosive. The directive encompasses explosion protection guidelines 94/9/EG for devices and 1999/92/EG for operations. ATEX guidelines are devised by the Director General of the EU commission Enterprise and Industry in cooperation with the member states, standardization orJDQL]DWLRQV&(1&(1(/(&DQGVRFDOOHGNQRZQRUJDQL]DWLRQVVXFK DV%$037%RU78(9WRQDPHH[DPSOHVIURP*HUPDQ\ IECEx is an internationally used process to certify electrical equipment used in hazardous locations. The code defines a system to classify locations prone to explosive atmospheres caused by gases, dusts, or fibers for example. The main goal of the International Electrotechnical Commission IEC with the IECEx regulation is to reach global harmonization of codes governing use of electrical apparatus in hazardous locations. IEC promotes mutual acceptance of evaluations and reports among the testing labs and certifying bodies. SIL “Safety Integrity Level” considers functional safety determine the potential risk for people, systems, devices and processes in case of a malfunction. Basis for the specification, design, and operation of safety LQVWUXPHQWHGV\VWHPVLV,(&VWDQGDUG7KHJRDOLVWRDVVHVVWKH risk and to reduce it by use of suitable measures. The standard knows four levels, SIL 1-SIL 4, characterizing safety levels for electrical, electronic and programmable electronic devices, often referred to as E/E/ PE. The SIL level is a measure for the safety function in case of a fault and answers the question: What is the probability of the system still functioning correctly in case of a fault? IP66 IP66 stands for Ingress Protection and denotes the protection of the device against environmental factors, dust and rain for example, as well as protection of living beings against dangers of touching high voltage circuits for example. The first digit categorizes ingress of solid objects, the second ingress of water: ,3[ GXVWSURRI ,3[ ZDWHUMHWSURRIZLWKVSHFLILHVZDWHUSUHVVXUHHWF INMETRO 1DWLRQDO ,QVWLWXWH RI 0HWURORJ\ 4XDOLW\ DQG 7HFKQRORJ\ is Brazil’s government body responsible for the implementation of measurement, safety and quality standards for electrical and electronic products. It guides the activities of accreditation, inspection, testing and certification bodies in the country. 60 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 Certification with highest protection classes ATEX IECEx SIL ,3,10(752 CSA UL GOST-R 571.26+$ CSA is a global provider of testing and certification services. CSA is also on the OSHA list of nationally recognized testing laboraWRULHV157/ UL is an independent organization testing and certifying product with regards to safety. UL tests and evaluates compliance of products, components, materials, and systems against specific requirements. As a result the UL mark can be carried as long as the standards are kept to. UL is one of the OSHA endorsed testing labs. OSHA is the Occupational Safety and Health Administration and maintains a list of ODEVFDOOHG157/VKRUWIRUQDWLRQDOO\UHFRJQL]HGWHVWLQJODERUDWRULHV GOST-R denotes a certification obligatory for goods to be imported to the Russian Federation. Compliance has to be evaluated and approved based on Russian standards. GOST-R certification is required for examples as follow: Food and food packaging Electronic devices Industrial plants and machinery Products used in the oil & gas industry Electronic and technical systems RTN RTN LV VKRUW IRU ³5RV7HNK1DG]RU´ 571 FHUWLILFDWHV DUH UHTXLUHG LQ Russia for industrial processes involving hazardous materials and conGLWLRQVDQGDUHUHTXLUHGIRUWKHHTXLSPHQWXVHG571DSSURYHVWKHXVH RIWKHHTXLSPHQW571DSSURYDOVDUHJHQHUDOO\QHFHVVDU\IRUH[DPSOH for all equipment used in the Oil & Gas industry all equipment requiring explosion protection KOSHA.RUHD2FFXSDWLRQDO6DIHW\DQG+HDOWK$JHQF\DLPVWRFRQtribute to the national economy by maintaining and improving the safety and health conditions at work through the efficient implementation of projects such as research and development, promotion of industrial accident prevention technologies, provision of technical assistance and training on occupational safety and health, inspection on dangerous facilities and equipment. www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 61 Technical short info 2014 62 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Information about electrical explosionproof according ATEX 94/9/EC Regulations for explosion protection The type plate and its components Explosion protection regulations in the EU member states are marked by the change of EU protection JXLGHOLQH(:*IIWRWKHWZRQHZ(8JXLGHOLQHV(&$7(;DQG&$7(; $V D UHVXOW RI WKH QHZ GLUHFWLYHV H[SORVLRQ protection in European regulations there will be a harmonisation of standards. There will be a transitional period to adjust from the “old” to the “new” European law. The regulations covering the “old” law were in effect up to June 30th 2003. Since July 1st 2003, electric explosion proof equipment must comply with ATEX Ex-protection guidelines in accordance with 94/9/EC – on the approximation of the laws of the Member States concerning equipment and protective systems for use in potentially explosive atmospheres. Information on uniform classification of potentially explosive systems and how to use this as a basis for selecting and classifying systems and equipment, incl. their installation, can be found in guideOLQH(&$7(; ATEX: Guideline 94/9/EC of the European parliament and the Council from March 23rd 1994 brought the legislation of the member states, concerning equipment and protective systems for use in explosion risk areas, into line. ExVO: Directive on the distribution of equipment and protection systems for potentially explosive arHDV±H[SORVLRQSURWHFWLRQSUHVFULSWLRQ*6*9 ElexV: Operational Safety regulation, minimum regulation in order to improve health-safety and VHFXULW\RIHPSOR\HHVDWKD]DUGRXVZRUNSODFHV The type plate and its components From 1/7/2003 the new ATEX guidelines come into force. The then current legal bases for the certification and labelling of electric explosion proof equipment is the EC guideline: Certificates Corresponding approvals and certificates are required for electrical explosion proof equipment. Testing must be carried out by an official testing DJHQF\IRUH[DPSOHWKH37%3K\VLNDOLVFK7HFKnische Bundesanstalt in Braunschweig/Federal German Physical and Technical Institute of BraunVFKZHLJ $7(; DSSURYDOV DUH DOVR DFFHSWHG LQ many countries and states outside Europe. Responsibilities The responsibility for compliance with all regulations and guidelines, from production to planning, up until installation, operation and maintenance, has greatly increased Each individual must be conscious about the fact that he accepts personal responsibility as part of a total project: building owner end-user architect consulting engineer /control company inspection authority contractor /installer manufacturer product supplier maintenance engineers Example, for the labelling of a quarter turn actuator: Manufacturer’s name, manufacturer’s address, GHVLJQDWLRQ RI W\SH HOHFWULFDO GDWD 9 $ : +] DPELHQWWHPSHUDWXUHLIGLIIHUHQWIURPíWR& unit serial number, in addition to the classification of Ex protection. Made in Germany 90579 Langenzenn ExMax-15-SF 24...240 VAC/DC, 15 Nm Ta = −40…+40/+50 °C PTB 04 ATEX 1028X IECEx PTB 07.0057X II2(1)G Ex d [ia] IIC T6/T5 II2(1)D Ex tD [iaD] A21 IP66 T130°C Correct installation For the installation of electrical systems in areas with explosive gas atmospheres of group II, rule ,(&(1ZLOODSSO\ Electric circuits of protection types d, e, q, o, m, p Installation in the panel is identical to “standard” installation, however the procedures for connecting Ex equipment must be followed. This refers, for example to voltage, current, fuses and motor protection equipment, etc. The requirements for specific products must be taken from their corresponding test certificates, standards and prescriptions as well as from the guidebook. It is only permitted to ZRUNRQHOHFWULFFLUFXLWVZLWKLQWKH([DUHDIRUH[ample when connecting to Ex-e terminal box if the YROWDJH KDV EHHQ VZLWFKHG RII$Q ([H WHUPLQDO box should only be opened after the voltage has been switched off. intrinsically safe circuits to prevent confusion and/ or linking up to a non-intrinsically safe circuit. Examples: cabels, cables, cable conduits, dampers, connection boxes, cable connectors,... A minimum distance of 50 mm should be allowed between intrinsically safe and non-intrinsically safe FLUFXLWVDQGDPLQLPXPGLVWDQFHRIPPEHWZHHQ two different intrinsically safe circuits. During installation the cables of intrinsically safe and nonintrinsically safe circuits should be laid out sepaUDWHO\ Suggestion on how to create a pannel It is necessary to keep intrinsically safe and nonintrinsically safe equipment separate. It is recommended, in this case, that a sufficient distance be kept, to avoid extra costs in the future. Large transformers, frequency rectifiers, large relays and other electric equipment that may influence intrinsically safe circuits by inductance or capacitance should be installed at a sufficient distance. As a precaution Ex-i equipment should have a suitable cover to protect it from incorrect handling. The appropriate standards and regulations must be observed. ATEX Atmosphère Explosible Electric circuits of protection type “i” (intrinsically safe) For the planning and operation of switchgears and control systems installed in the safe area, but which contain circuits leading into the Ex-area, certain requirements should be considered. This applies especially to intrinsically safe circuits. Intrinsically safe circuits and non-intrinsically safe circuits should EH NHSW VHSDUDWH 0LQLPXP GLVWDQFHV GLVWDQFHV between bare connections must be observed, the cables must not produce any inadmissible external inductance or capacitance. The maximum admissible electrical limits of Ex-i equipment must be observed at all times. Intrinsically safe and nonintrinsically safe electrical circuits should not cross, however it is allowed between two intrinsically safe circuits. Intrinsically safe circuits must be clearly marked. Intrinsically safe circuits are marked by a “light blue” color. This color is recommended for all www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 63 Technical short info 2014 Labelling of explosion proof equipment according to ATEX 94/9/EC Classification and labelling of explosion proof areas Flammable medium Classification Explosion groups & Temperature classes Hazardous locations Classification Product classification Product of explosion level Probability of a proof areas (EPL) potential explosive Product Product atmosphere occuring group category Explosion group Always, temporarily or often present Zone 0 II IIA Occasionally present Zone 1 II IIB Gases, mists, vapours 1G 2G Dusts Very seldom or only present for a short period Zone 2 II Always, temporarily or often present Zone 20 II Occasionally present Zone 21 II Gb 3G Zone 22 Institute Notified Body (NB) 0102 0158 PTB (Germany) EXAM (Germany) Ethanol Cyclohexene n-Butane Petrol Diesel fuel Fuel oil n-Hexane Acetal-dehyde City gas Acrylic nitrile Ethylene Ethylene oxide Ethyl glycol Carbon hydrogen Ethyl ether Hydrogen Acetylene T1<450°C Attention: this list is only an extract of possible flammable mediums and does not claim to be complete! Carbon disulphide Gc 1D T3<200°C Da T4<135°C Db 3D II T5<100°C Dc T6< 85°C Official institutes code number Ammonia Methane Ethane Propane T2<300°C 2D Does not occur or only seldom for a short period IIC Ga Examples depending on - explosion group - temperature class Product use depending on temperature class (T1 - T6). The temperature class indicates the max. temperature of the exposed surface of the product. For dust explosion proof, the max. surface temperature is directly shown (e.g. T80°C). Temperature class Example: 0158 II 2G Ex d IIC T6 Gb II 2D Ex tb IIIC T80°C Db Prevents transmission of the explosion outside flameproof enclosure Ex d 1, 2 EN 60079-1 IIIA NB 12 ATEX 1007 X flammable fibres IIIB IIIC non conductive dust Prevents high temperatures and sparks increased safety Ex e Low current / voltage supply intrinsic safety Ex i ¹ Ex iD ² 0, 1, 2 EN 60079-11 20, 21, 22 Positive pressure device pressurised apparatus Ex p Ex pD 1, 2 21, 22 moulding Ex m ³ Ex mD ʎ 0, 1, 2 EN 60079-18 20, 21, 22 1, 2 EN 60079-6 1, 2 EN 60079-5 Encapsulated EN 60079-7 1, 2 EN 60079-2 oil immersion Ex o Prevents transmission of explosion outside powder filling Ex q As above, but for use in zone 2 protection “n” Ex n 2 Dust explosion proof protection “tD” Ex t ʏ 20, 21, 22 EN 60079-31 Protection principle Type of protection Code ia (zone 0, 1, 2), ib (zone 1, 2), ic (zone 2) iaD (zone 20, 21, 22), ibD (zone 21, 22), icD (zone 22) 64 7 IP66 EN 60079-15 Symbol To use CENELEC in zone 3 4 – For use under special circumstances X This product is an Ex-certified component for use in a complete system U Dust classification – – 1 totally protected against dust dust - limited ingress solids objects > 1 mm solids objects > 2,5 mm solids objects > 12,5 mm solids objects > 50 mm 0 no protection 5 3 6 2 8 4 Protection principle – Type of protection – EN 60079-0 General Requirements 1 Code 6 Parts immersed in oil to isolate from explosive atmosphere For common use conductive dust 2 IP Protection against solids/dust long periods of immersion the effects of temporary immersion strong jets of water low pressure jets from all directions sprays from all directions direct sprays up to 60° from vertical direct sprays up to 15° from vertical vertical falling drops of water no protection Protection against water Ingress Protection EN 60529 ma (zone 0, 1, 2), mb (zone 1, 2), mc (zone 2) maD (zone 20, 21, 22), mbD (zone 21, 22), mcD (zone 22) 5 6 Application Code Further information ta (zone 20, 21, 22), tb (zone 21, 22), tc (zone 22) Highest possible application areas www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 Where and when do I have to take explosion proof into consideration ? Explosion proof means: “Protection of Life. Health. Assets.” Is your system safe ? What creates an explosion ? An explosion may occur when the following 3 components are present at the same time: Flammable or combustible media Source of ignition $LUR[\JHQ ƑƑ ƑƑ ƑƑ ƑƑ Explosion Flammable Media We have the following situation NOW or in the FUTURE: <HV1R3OHDVHFKHFN ƑƑ ƑƑ Oxygen Source of ignition Flammable materials are stored. Flammable materials are used. Flammable materials are bottled. Flammable materials are used during the cleaning process. Flammable materials are used in the production process. Flammable materials will be produced during the production process. î³1R´2EYLRXVO\\RXGRQRW need explosion proof at least 1 × “YES”: When planning you have to consider rules, regulations and instructions concerning explosion proof Example: BetrSichV, ExVO, EX-RL Typical sources of ignition 9HU\RIWHQWKHUHDVRQIRUDFFLGHQWVLVVHOILJQLWLRQ extraordinary surface temperatures and sparks due to mechanical reasons. But there are also a lot of other sources of ignition, caused by either mechanical and/or electrical equipment. These are for example: Self-ignition Extraordinary surface temperatures Open flames Sparks caused by mechanical reasons Static electricity Lightning strike Ultra-sonic Chemical sources of ignition Electric sparks Electric arcs Adiabatic compression Adiabatic shock waves Electric balancing power Remarks: All information, tables, checklists and further documentation are only for your assistance and do not claim to be complete. In no way do they replace official regulations and rules or even laws by the authorities. We want to point out that it is very important to undertake all measures for an exact classification of the Ex-area. Typical Applications: Chemical, pharmaceutical and industrial plants Refineries, petrol depots, gas stations Paint and solvent shops Drying and coating cabinets Laboratories in industry and schools Water treatment works, power plants Compressor stations, gas works All kinds of storekeeping and stocks All kinds of filling stations All kinds of cleaning stations Mills, silos, silos for bulk goods Offhore and onshore Oil and gas pipelines 3ULQWLQJZRUNVIRRGLQGXVWU\« Schedule: Analyse whether you need explosion proof or not Ask experts in order to analyse the risk of danger Define zones, areas, categories, explosion groups and temperature classes Planning according to all necessary rules and regulations Choose the best supplier and the right product .HHSWRWKHLQVWDOODWLRQUXOHV Check the labelling of the equipment Make sure that the appliance will be put into operation correctly Confirm a final inspection by the responsible authority Guarantee regular and correct maintenance according to the regulations The correct documentation has to be maintained From fire to detonation Effect and reaction velocity increase significantly from combustion, deflagration, via explosion up to detonation. Effect When can a danger of explosion occur ? A danger of explosion occurs when a flammable PHGLXPJDVYDSRUPLVWRUGXVWLQDGDQJHURXV quantity is present. Detonation Explosion Deflagration Combustion Reaction velocity www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 65 Technical short info 2014 =RQHV Explosion groups Temperature classes Implementation Potentially explosive areas should be divided into zones, and the equipment should be divided into groups and categories. The labelling on the identification plate of certified equipment indicates in which zone the explosion proof equipment can be used. Division into equipment groups Groups are divided into group I and group II. Group I equipment is intended for use in underground parts of mines. Group II equipment is intended for use in areas where explosive atmospheres exist, except for underground mines. Division into zones Potentially explosive areas are divided into six zones, according to time-related and local probabilLW\WKDWDSRWHQWLDOO\H[SORVLYHDWPRVSKHUHSHD exists. A distinction is made between combustible gases, mists, vapors and combustible dust. The zones are described in the accompanying table. Gases, mists and vapors are placed in zones 0, 1 and 2, whereby the requirements for the chosen equipment increase from zone 2 to 0. Equipment in zone 0 must be built in a way “that even if a type of protection fails or if two faults occur, that sufficient explosion protection is guaranteed”. Therefore for example a passive, potential free sensor, installed in zone 0, and connected to an intrinsically safe HOHFWULF FLUFXLW ,,* >([ LD@ ,,& PXVW GLVSOD\ current approval. =RQHV DQG DUH IRU GXVW ZKHUHE\ WKH requirements for the chosen equipment increase from zone 22 to 20. Equipment in zone 20 and 21 need special approval. Division into product categories Product categories determine, in which zones the equipment should be installed. Once again there are six categories. Categories 1G, 2G and 3G are FODVVLILFDWLRQV IRU JDV H[SORVLRQ SURWHFWLRQ * *DVWRZKLFKHTXLSPHQWZLWK*IRU]RQHDQG 2, equipment with 2G for zone 1 and 2 and equipment with 3G for zone 2 are suited. Categories 1D, 2D and 3D are classifications for dust explosion SURWHFWLRQ' 'XVWWRZKLFKHTXLSPHQWZLWK' for zone 20, 21 and 22, equipment with 2D for zone 21 and 22 and equipment with 3D for zone 22 are suited. Classification and labelling of explosion proof areas Flammable medium Classification of explosion proof areas Hazardous locations Probability of a potential explosive atmosphere occuring Always, temporarily or often present Gases Vapours Mists Dusts Occasionally present Product Group Zone 0 II Zone 1 II Very seldom or only present for a short period Zone 2 II Always, temporarily or often present Zone 20 II Zone 21 II Occasionally present Does not occur or only seldom for a short period Zone 1 1G Ga Gb 3G 1D Gc Da 2D Zone 22 Zone 0, 1 and 2 Zone 2 Product Category Product level (EPL) 2G Zone 0 Gases-Mist-Vapours II Db 3D Dc Division into explosion groups Explosion proof equipment for gases, mists and YDSRUVLVGLYLGHGLQWRWKUHHH[SORVLRQJURXSV,,$ ,,%,,& DFFRUGLQJ WR WKH W\SH RI SURWHFWLRQ EHLQJ used. The explosion group is a means to measure WKH LJQLWDELOLW\ RI JDVHV SRWHQWLDOO\ H[SORVLYH DWPRVSKHUHV7KHHTXLSPHQWUHTXLUHPHQWVLQFUHDVH from II A to II C. Safe area II A II B II C An Example of a typical zone activity would be filling a barrel of petrol in an enclosed area. increasing requirements Zone 20, 21 and 22 Zone 22 Zone 21 Zone 20 Dust Safe area An example of a typical zone activity would be filling a grain silo in an enclosed area. Explosion groups, temperature classes The equipment groups and categories determine, in which zones the equipment should be installed, therefore the explosion groups and temperature classes determine, to which mediums inside the zones, the equipment is suited. The type of protection used is not a mark of quality but is instead a constructive solution for selecting equipment for explosion protection. 66 Product classification Division into temperature classes Explosion proof equipment, installed within the Ex DUHDLVGLYLGHGLQWRWHPSHUDWXUHFODVVHV7WR 77HPSHUDWXUHFODVVLVQRW±DVLWLVRIWHQZURQJO\ believed – the operating temperature range of the equipment, but the maximum permissible surface WHPSHUDWXUHRIWKHHTXLSPHQWLQUHODWLRQWR& ambient temperature on any surface area, and should not be exceeded at any time. The maximum surface temperature must remain below the ignition temperature of the surrounding medium at all times. The equipment requirements increase from 7WR7 T1 T2 T3 T4 450°C 300°C 200°C T5 135°C 100°C T6 85°C increasing requirements www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 Ex applications Air safety dampers Air control dampers Fire/smoke dampers Heating/ g/ ccooling ing control Air damper Ex area Duct M Duct Heater ExRun M ExCos-D + ExPro M ExCos-D + ExPro Safe area ExMax-... Humidity control The automatic damper control system consists of an actuator DQGD([&RV'WUDQVGXFHUZLWK([3UR&7«SUREH7KHFRPELnation can be installed directly into the Ex area. The transducer FRQYHUWVWKHSUREHVLJQDOLQWRDQDFWLYHVLJQDO9'&RU P$IRULQSXWLQD3/&V\VWHP7KHRXWSXWVLJQDOIURPWKH controller goes directly to the actuator. Between the sensor and controller there is no need for an Ex i module, or an intrinsically VDIH,6ZLULQJPHWKRGHLWKHU)RUWKHDFWXDWRUDQGWUDQVGXFHU WKHPD[LPXPSHUPLVVLEOHVXUIDFHWHPSHUDWXUHVKDVWREH taken into account. Controller Control of fire/ smoke dampers Duct Fire/ Smoke damper Ex area °C Sensor M ExCos-D + ExPro The humidity control system consists of a ExRun valve actuator DQG DQGDQ([&RV'WUDQVGXFHUZLWK([3UR&)«SUREH7KHFRPEL nation can be installed directly into the Ex area. The transducer FRQYHUWVWKHSUREHVLJQDOLQWRDQDFWLYHVLJQDO9'&RU P$IRULQSXWLQD3/&V\VWHP7KHRXWSXWVLJQDOIURPWKH controller goes directly to the actuator. Between the sensor and controller there is no need for an Ex-i module , or an intrinsically VDIH,6ZLULQJPHWKRGHLWKHU)RUWKHDFWXDWRUDQGWUDQVGXFHU VDIH WKHPD[LPXPSHUPLVVLEOHVXUIDFHWHPSHUDWXUHVKDVWREH WKH taken take into account. Controller Differencial pressure control/ VAV In applications for fire /smoke dampers, the actuator has to reliably return the damper to its safety position via an external swit switch/contact. The actuator will return the damper to its safety position by an internal spring. The contact comes from a safety ther thermal trigger type ExPro-TT-.. which is directly connected to the actuator. Duct Fan Sensor M Orifice plate (by others) ExCos-P The DP control system consists of an actuator and a differential pressure ExCos-P transducer. The combination can be installed dire directly into the Ex area. The transducer converts the differential SUHVVXUHVLJQDOLQWRDQDFWLYHVLJQDO9'&RUP$ for input in a PLC system. The output signal from the controller goes directly to the actuator. Between the sensor and controller LVQRQHHGIRUDQ([LPRGXOHRUDQLQWULQVLFDOO\VDIH,6ZLULQJ method either. The controller, situated in the safe area will, depe depending on changing circumstances will monitor, control a fan PXVWEH([SURRIRUDPRGXODWLQJGDPSHUDFWXDWRUDOVR([ SURRIWRPDLQWDLQWKHUHTXLUHGDLUYROXPH SUHVVXUH Safe area ExPro-TT-.. ExMax-... ExRun Humidifier Safe area M Duct Ex area Air damper Ex area Ex area Duct The heating/cooling control system consists of an actuator and D([&RV'WUDQVGXFHUZLWK([3UR&7«SUREH7KHFRPELQDWLRQ D([ can be installed directly into the Ex area. The transducer FRQYHUWVWKHSUREHVLJQDOLQWRDQDFWLYHVLJQDO9'&RU P$IRULQSXWLQD3/&V\VWHP7KHRXWSXWVLJQDOIURPWKH controller goes directly to the actuator. Between the sensor and controller there is no need for an Ex-i module, or an intrinsically VDIH,6ZLULQJPHWKRGHLWKHU)RUWKHDFWXDWRUDQGWUDQVGXFHU VDIH WKHPD[LPXPSHUPLVVLEOHVXUIDFHWHPSHUDWXUHVKDVWREH WKH taken into account. take Controller Safe area Automatic air damper control Sensor + Safe area Safe area ExMax-... Schischek actuators are approved for direct installation and operation in explosion risk areas, as they are of the highest oper explosion groups and temperature class and are suitable for expl all gases, vapours, steam and dust. The electrical connection LVPDGHYLDDQH[SORVLRQSURRIWHUPLQDOER[W\SH([%R[ Please ensure during installation that all cables are securely fixed and connected in such a way that they are protected from fixe mechanical damage. Ex area Air damper mpe control Heating Cooling Humidification Diff.pressure control 9$9 Thermostats Humidistats Pressurestats Filter monitoring Fan belt monitoring Frost protection Drive belt monitoring ing with differential pressure sensor/ air paddle Duct Thermostat + Fan M ExBin-P Duct ([%LQ3«PRGXOHVDUHSUHVVRVWDWVOLNH([GLIIHUHQWLDOSUHVVXUH VZLWFKHVHJIRUIDQEHOWPRQLWRULQJLQH[SORVLRQSURRIDUHDV1R VZLW intrinsic safe electrical circuit and, no transducer in the electrical control-panel are necessary. The module should be installed dire directly into Ex area, depending on demand in zone 1, 2, 21 or 22. To indicate fan failure switching modules are delivered with integrated time running relay with delay on start up. The output FRQWDFWFDQEHXVHGIRUVHTXHQFHIXQFWLRQVUHOD\VFRQWDFWV GLUHFWFLUFXLW« GLUH Drive belt monitoring with inductive sensor Hygrostat Duct Fan M ExBin-N Safe area Safe area Ex area ExBin-D + ExPro-B ([%LQ'«PRGXOHVZLWK([3UR%)«LVDVHQVRUSUREHZLWK DK\JURVWDWIRUXVHLQH[SORVLRQSURRIDUHDV1RLQWULQVLFVDIH DK\ electrical circuit and no transducer in the electrical control-panel elec are necessary. The module should be installed directly into Ex area, depending on demand in zone 1, 2, 21 or 22. The output area FRQWDFWFDQEHXVHGIRUVHTXHQFHIXQFWLRQVUHOD\VFRQWDFWV GLUHFWFLUFXLW« GLUH Ex area Hygrostats Duct ([%LQ1«PRGXOHVZLWKFRQQHFWHG1DPXUVHQVRULQGXFWLYH SUR[LPLW\VZLWFKDUHHVSHFLDOO\IRUFRQWDFWIUHHIDQEHOWPRQLWRring of ventilators, for use in explosion proof areas. 1RLQWULQVLFVDIHHOHFWULFDOFLUFXLWDQGQRWUDQVGXFHULQWKH electrical control-panel are necessary. The module should be elec installed directly into Ex area, depending on demand in zone 1, 2, 221 or 22. To indicate fan failure switching modules are delivered with integrated time running relay with delay on start up. vere 7KHRXWSXWFRQWDFWFDQEHXVHGIRUVHTXHQFHIXQFWLRQVUHOD\V 7KH FRQWDFWVGLUHFWFLUFXLW« Frost protection Filter Duct Heater Sensor + ExRun M ExBin-FR ([%LQ)5«DUHVHQVRUVDUHIRUIURVWSURWHFWLRQPRQLWRULQJZLWK a ca capillary as measuring element for use in explosion proof DUHDV1RLQWULQVLFVDIHHOHFWULFDOFLUFXLWDUHQRWUDQVGXFHULQ DUHD the electrical control-panel are necessary. The module should be installed directly into Ex area, depending on demand in zone 1, 2, 21 or 22. The output contact can be used for sequence IXQFWLRQVUHOD\VFRQWDFWVGLUHFWFLUFXLW« IXQF Safe area Safe area ExBin-P ([%LQ3«PRGXOHVDUHSUHVVRVWDWVOLNH([GLIIHUHQWLDOSUHVVXUH VZLWFKHVHJIRUILOWHUPRQLWRULQJLQH[SORVLRQSURRIDUHDV1R VZLW intrinsic safe electrical circuit and, no transducer in the electrical control-panel are necessary. The module should be installed directly into Ex area, depending on demand in zone 1, 2, 21 dire or 222. The output contact can be used for sequence functions UHOD\VFRQWDFWVGLUHFWFLUFXLW« Ex area Filter monitoring Ex area Duct Safe area Safe area Ex area ExBin-D + ExPro-B ([%LQ'«PRGXOHVZLWK([3UR%7«LVDVHQVRUSUREHZLWK DW DWKHUPRVWDWIRUXVHLQH[SORVLRQSURRIDUHDV1RLQWULQVLFVDIH elec electrical circuit and no transducer in the electrical control-panel are necessary. The module should be installed directly into Ex area, depending on demand in zone 1, 2, 21 or 22. The output area FRQWDFWFDQEHXVHGIRUVHTXHQFHIXQFWLRQVUHOD\VFRQWDFWV GLUH GLUHFWFLUFXLW« Ex area Thermostats Controller www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 67 Technical short info 2014 SIL “Safety Integrity Level” Schischek “..Max” actuators with spring return according SIL - Structural measures - Evacuation plans - Safety components - PLC protective device n Remaining Risk unity Response Comm Plant Response Relief Devices a Autom tic SIS Alarms l a c i Crit Desig s s e roc P Risk reduction Risk (without security measures) Risk 1. Functional Safety 7KHVDIHW\LQWHJULW\OHYHO6,/DOORZVWRGHWHUPLQH the potential risk for people, systems, devices and processes in case of a malfunction. Basis for the specification, design, and operation of safety instruPHQWHGV\VWHPVLV,(&VWDQGDUG Process The goal is to assess the risk and to reduce it by use of suitable measures 2. Standard 6WDQGDUG GHILQHV VDIHW\ GHSHQGLQJ RQ WKH OHYHORILQWHJULW\DQGWKHSUREDELOLW\« HQFRPSDVVHVLWVRZQULVNDVVHVVPHQWZLWK which the safety integrity levels for the safety related devices and systems can be determined. The standard knows four levels, SIL 1 to SIL 4, characterizing safety levels for electrical and electronic devices. The SIL level is a measure for the safety function in case of a fault and answers the question: What is the probability of the system still functioning correctly in case of a fault ? MTBF = Mean Time Between Failure MTBF is applicable only to repairable devices or systems and time between failures assumes that the device has been repaired after a failure. MTBF can be used to estimate failures per time interval. That allows to calculate the probability of a device IDLOXUHGXULQJLWVOLIHVSDQIRUH[DPSOH\HDUVIRU 6FKLVFKHNDFWXDWRUV07%)IRUDJLYHQGHYLFHFDQ be estimated in life cycle tests. Those tests can be conducted under increased stress conditions of a highly accelerated life test, such as radiation, humidity, vibration, high temperatures etc. 3. Specific values PFD = Probability of failure on demand PFDav directly describes the probability that the system will malfunction on demand, i.e. when a service request is made or during a continuous temperature measuring. The standard defines different levels of demand and high demand is, as the name implies, when safety related functions are required in a continuous mode of operation. Low demand is where the frequency of demands for operation made on a safety-related system is no greater than one per year. The differences are reflected in the mathematical treatment. High demand looks at failure probability per hour versus low demand at probability of failure per demand. SIL – PFDav – PFH – modes of operation Safety Integrity /HYHO6,/ Low demand mode operation High demand mode operation SIL4 -5 to < 10-4 -9 to < 10-8 SIL3 to < 10 -3 -8 to < 10-7 SIL2 to < 10 -2 to < 10 SIL1 -2 to < 10-1 -4 -3 -7 MTTF = Mean Time To Failure also used as average mean time to failure MTTFd. The importance of MTTF has been increased by WKH(XURSHDQ1RUP(1,62LQFRQQHFWLRQ with machine safety. MTTF is a statistical quantity based on test results or empirical data and does not constitute a guaranteed life cycle or failure free operating time. 077)LVEDVHGRQWKHUHOLDELOLW\IXQFWLRQ5WDQGLV valid under the assumption that that the device in consideration is “as new” after a repair. Another way to determine MTBF is the reliability prediction, often used in early design stages where devices and systems are not yet available. That allows to evaluate if the target reliability can be achieved but, it requires detailed knowledge of the construction of a device and its components. Failure rates are available for many components and published in PDQXDOV9DOXHVJLYHQLQ),7ZKLFKVWDQGVIRUIDLOXUH in time and is a unite defined as 1 FIT = 109 per hour. MTBF is the reciprocal of the calculated failure rate of the component, which in turn is the sum of the application condition dependent failure rates of the individual components. When used in MTBF calculations FIT is usually used without the unit “failures in 109 hours.” If, for example, MTBF for a repairable device is affected by a component for which FIT is known, then MTBF can be calculated based on the following formula: Formula: MTBF = 114.000 years to < 10-5 FIT Example: for a FIT of 1140 follows MTBF = 100 years 68 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 SIL “Safety Integrity Level” Schischek “..Max” actuators with spring return according SIL MTTR also encompasses work and material planning and should be kept as short as possible. ȝ )DLOXUH5DWH 7KHIDLOXUHLVWKHUHFLSURFDORI07%)Ȝ 07%) Ȟ 5HSDLU5DWH The repair rate is the reciprocal of MTTR. Ȝ 0775 SFF = Safe Failure Fraction 6))LVWKHSURSRUWLRQRIVDIHHUURUVȜVDIHLQUHODWLRQWRGDQJHURXVHUURUVȜGDQJHURXV7KHKLJKHU SFF the lower the probabilty of failure. Ȝtotal ȜS ȜD HFT = 0: no redundancy, a single fault can result in loss of safety. HFT = 1: “simple” redundancy, at least two faults are necessary to cause a safety failure. HFT = 2: double redundancy, at least 3 faults are necessary to result in a loss of safety. Safe Failure Fraction 6)) = safe = safe detected = safe undetected = dangerous = dangerous detected = dangerous undetected Hardware Fault 7ROHUDQFH7\SH$± VLPSOHVXEV\VWHP 0 OSD OS OD ODD ODU Concept Hazard and risk analysis Safety requirements Planning, realization 1 2 Hardware Fault 7ROHUDQFH7\SH%± FRPSOH[VXEV\VWHP 0 Operation, maintenance, repair Modification, retrofit Decommissioning, disposal SIL1 SIL2 SIL3 – SIL1 SIL2 « SIL2 SIL3 SIL4 SIL1 SIL2 SIL3 « SIL3 SIL4 SIL4 SIL2 SIL3 SIL4 SIL3 SIL4 SIL4 SIL3 SIL4 SIL4 :LWKSURYHQLQXVHGHPRQVWUDWLRQDFFWR,(&RQO\IRU6,/ OSU Safety Lifecycle Installation, commissioning Since the safety function of all individual parts has to be taken into consideration a fully redundant architecture may be necessary depending on the required SIL level. SFF – HFT – SIL – Type A, Type B 6)) ȜDU Ȝtotal ȜS Ȝ SD Ȝ SU ȜD ȜDD ȜDU HFT = Hardware Failure Tolerance The hardware failure tolerance HFT together with the safe failure fraction SFF determines the safety integrity level SIL. HFT categorizes the amount of faults a system can endure without failing as a system. The higher HFT the higher is the system availability. back to appropriate phase MTTR = Mean Time To Repair is a measure of how long it takes on average to repair a device after failure and is therefore important in conjuction with system availability. Management of functional safety and functional safety assessment Qualification, training and documentation Needed documents for certification: Product Specification Functional Specification Safety Requirement Specification Development plan 9HULILFDWLRQDQG9DOGLDWLRQ3ODQ Hardware development documents Software development documents Construction drawings +DUGZDUH9HULILFDWLRQDQG7HVWSODQV Hardware Test results 6RIWZDUH9HULILFDWLRQVDQG7HVWSODQV Software Test results )DLOXUH0RGHDQG(IIHFWV$QDO\VLV)0($ Quantitativ verification of safety Technical customer documentation www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 69 Introduction For over fifty years, engineers have relied upon Rotork for the most innovative and dependable valve actuation and flow control solutions. From safety systems that may be needed just once in a lifetime to high precision controls that are constantly on the move, Rotork products remain the clear choice, worldwide. Committed to Innovation Leaders in Flow Control With every product that Rotork develops, you can be sure of one thing: That quality and reliability are an integral part. From its inception over 50 years ago, Rotork has grown to be a major international business with subsidiaries all around the world. Throughout the company’s history, our engineers have focused on solving customer challenges and developing new solutions with levels of engineering skill and creativity that our competitors still cannot match. Some innovations are adopted almost immediately, whilst others may require thousands of hours of testing and certification before they can be offered to our customers. Serving the World We are recognised as global leaders, designing and building the most reliable products, backed up by highly acclaimed customer service. Rotork has always been committed to a global customerbase, supporting operations in some of the most remote and challenging environments. A genuine, long-term commitment to customers and partners underpins our culture of engineering excellence, making Rotork a consistently dependable choice for products and service. We have established manufacturing facilities across the globe plus over 350 offices and regional centres of excellence. These provide our staff with all the training and support they need to deliver excellent service, wherever they are needed. Whether you work directly with Rotork or engage through a partner, you can be confident that our products and support remain the best in the world. 70 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Electric Control Valve Actuators (Extraction) t t t t t t t t t t t Linear and rotary actuators Linear, quarter-turn and rotary actuators CVA CMA range range Linear: Thrust range 890 to 22,241 N (200 to 5,000 lbf) Rotary: Torque range 54.2 to 271 Nm (480 to 2,400 lbf.in) High performance, continuous unrestricted modulating duty - S9 High resolution and repeatability Pakscan, HART®, Profibus®, Modbus and Foundation Fieldbus® available. Optional hard wired RIRO (Remote In Remote Out) Comprehensive data logging Watertight IP68 and explosionproof enclosures Programmable fail-to-position option Temp. range -30 to 70 ºC (-22 to 158 ºF) + Low Option ‘Intrinsically Safe’ control & instrumentation. Non-intrusive setup / calibration using Bluetooth® wireless technology Optional manual override The Rotork CMA is suitable for almost all linear, quarter-turn and rotary control valve and pump applications requiring exact position control and unrestricted continuous modulation. t t t t t t t t Linear: Thrust range 178 to 3,336 N (40 to 750 lbf) Rotary/ QT: Torque range 2.3 to 113 Nm (20 to 1,000 lbf.in) Permanently lubricated and maintenance free drive train Accurate and repeatable position control Pakscan, HART, Profibus, Modbus and Foundation Fieldbus available. Optional hard wired RIRO (Remote In Remote Out) Temp. range -30 to 70 ºC (-22 to 158 ºF) + Low Option Electronic thrust/torque limiting Manual override standard IQ – multi-turn actuators ROM – compact and lightweight design IQ ROM range range Intelligent communication options and multilingual display. The IQ offers multi- and quarter-turn isolating / regulating duty. t Torque range: Multi-turn direct drive 14 to 3,000 Nm (10 to 2,200 lbf.ft) Multi-turn with IS or IB gearbox, up to 40,800 Nm (30,000 lbf.ft) Quarter-turn with IW gearbox up to 250,000 Nm (185,000 lbf.ft) t Complete integrated motor control t Infra-red or Bluetooth® wireless technology for simple setup and adjustment t Digital, analogue or bus system remote control and status reporting t Comprehensive software tools for plant records and valve performance analysis Building on the simple specification of the ROM / RBM range, Rotork now offer a more complete control solution with the introduction of the new ROMpak. ROMpak introduces: Local controls for ease of operation; Dual local indicators – mechanical and LED; Phase rotation correction for ease of installation. Options include: Bluetooth non-intrusive configuration, bus communication, Folomatic / CPT and datalogger. t t t t t Torque range 35 to 650 Nm (25 to 480 lbf.ft) Efficient yet simple gearing Wide range of supply voltages available Single-phase, three-phase and DC options Watertight IP67 rating www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 71 Fluid Power Actuators (Extraction) t t t t t t Vane actuators Pneumatic rack and pinion actuator K-TORK GT range range Pneumatic actuators in double-acting and spring-return configurations Compact no-sideload, constant-torque design with output to 16,950 Nm (150,000 lbf.in) Complies with EN60529 (1991) + (A1:2000) for IP67M Complies with ANSI/ AWWA C540-02 and C541-08 Conforms to VDI/ VDE 3485 control accessory mounting standards Modulating accuracy of 0.25 % or better t t t t t t t t t Pneumatic rack and pinion actuator Double-acting and spring-return configurations Constant torque range from 3 to 15880 Nm Valve interface according ISO 5211/ DIN 3337 Solenoid valve interface according NAMUR VDI / VDE 3845 Feedback /accessory interface according NAMUR VDI/ VDE 3845 Standard certifications: ATEX, CE, SIL3, GOST, RTN Options: epoxy-coating, hardanodizing, electric nickel plating, stainless steel pinion, speed regulation (other possible, on request) Single limit stop or double limit stop version Compact scotch yoke actuators Electro-hydraulic actuators RC200 RCI200 Skilmatic range ranges t t t t t t t t t 72 Extremely compact scotch yoke pneumatic actuator Double-acting and spring-return configurations Contained spring module for safety and convenience Torque output to 4,400 Nm (38,000 lbf.in) Valve mounting dimensions per ISO 5211/ DIN 3337 Compatible with SVM partial stroke testing Certified suitable for use at SIL3 as a single device in accordance with IEC 61508 Actuators certified in accordance with PED 97/23/EC Actuators certified to ATEX 94/9/EC Skilmatic range SIL3 certified Intelligent, self-contained electrohydraulic actuators feature Rotork double-sealed terminal compartments and user displays for position, pressure, diagnostics and fault indication. t t t t t t t Linear thrusts: 1.7 to 5,500 kN (382 to 1,230,000 lbf) ¼ turn torques: 65 to 600,000 Nm (575 to 5,000,000 lbf.in) Two-position, ESD or modulating operation in spring-return or double-acting executions Single-phase, three-phase or 24 VDC power supply Non-intrusive infrared configuration and Bluetooth® data transfer Optional bus communications via all major protocols Partial stroke test capability Watertight or explosionproof ATEX, FM, CSA IEC and GOST www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Worldwide Service Greenland Sweden Iceland Finland Norway R u s s i a Estonia C a n a d a Latvia United Kingdom Denmark Neth. Ireland Bel. Belarus Germany France Lux. Czech Rep. Slovakia Licht. Austria Hungary Switz. Italy Spain Portugal United States Lithuania Poland Slovenia Croatia Ukraine Kazakhstan Mold. Romania Bos. & Herz. Serb. Mont. Mongolia Bulgaria Georgia Armenia Azerb. Albania Mace. Greece Kyrgyzstan Uzbekistan Turkmenistan Tajikistan Turkey Gibraltar Cyprus Syria Lebanon Israel Jordan Malta Tunisia Morocco Cuba Belize Jamaica Honduras Guatemala El Salvador Costa Rica Libya Egypt (Occupied by Morocco) Dom. Rep. Puerto Rico Cape Verde Panama Venezuela Trinidad & Tobago Guyana French Guiana Suriname Colombia Senegal Gambia Guinea-Bissau Guinea Sierra Leone Liberia Bhutan Bangladesh Mali Burkina Faso Benin Cote Togo d'Ivoire Ghana Niger Oman Chad Eritrea Sudan Vietnam Cambodia Dijbouti Taiwan Philippines Thailand Yemen Nigeria Ethiopia CameroonCentral African Republic Equatorial Guinea Somalia Sri Lanka Uganda Kenya Congo Rwanda Gabon Dem. Rep. Burundi of Congo Peru Palau Brunei Malaysia Singapore I Tanzania B r a z i l Hong Kong Laos India Ecuador n d o n e s i a Papua New Guinea Solomon Islands East Timor Angola Malawi Zambia Somoa Vanuatu Fiji Bolivia Chile Nepal Pakistan Saudi Arabia Mauritania Haiti Nicaragua Japan S. Korea a Afghanistan Iraq Kuwait Bahrain Qatar U.A.E. Algeria Western Sahara Bahamas Mexico N. Korea C h i n Iran Namibia Paraguay Zimbabwe Botswana Mauritius Mozambique Swaziland Lesotho Tonga Madagascar A u s t r a l i a South Africa Argentina Uruguay Rotork Sales Agents Rotork Sales Offices and Agents New Zealand Rotork Manufacturing Plants, Sales Offices and Agents In each of our divisions, Site Services staff are dedicated to providing customer service and support, carrying out new installations and delivering retrofit projects. These teams are based out of service centres around the world and are complemented by factory-trained agents. Our expert technicians support Rotork customers, allowing us to deliver on our promise of global solutions backed by local service. www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 73 Technical short info 2014 Notices 74 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl Technical short info 2014 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl 75 Schischek sales worldwide Greenland Sweden Iceland Finland R u s s i a Norway Estonia C a n a d a United Kingdom Latvia Denmark Lithuania Neth. Ireland Bel. France Lux. Czech Rep. Licht. Switz. Austria Italy Ukraine Slovakia Bulgaria Uzbekistan Georgia Armenia Azerb. Greece Gibraltar Mongolia Romania Bos. & Serb. Herz. Mont. Albania Mace. Turkmenistan Turkey Tunisia Kyrgyzstan N. Korea Tajikistan Syria Cyprus Lebanon Israel Malta Morocco Kazakhstan Mold. Hungary Slovenia Croatia Spain Portugal United States Belarus Poland Germany C Iran Iraq S. Korea h i n a Japan Afghanistan Jordan Algeria Cuba Belize Guatemala El Salvador Haiti Cape Verde Gambia Guinea-Bissau Trinidad & Tobago Panama Venezuela Guyana French Guiana Colombia Senegal Suriname Guinea Sierra Leone Liberia Mali Burkina Faso Benin Cote Togo d'Ivoire Ghana Niger Chad Eritrea Sudan Cambodia Hong Kong Taiwan Philippines Vietnam Ethiopia Cameroon Central African Republic Sri Lanka Somalia Uganda Congo Dem. Rep. of Congo Palau Brunei Malaysia Singapore Kenya Rwanda Burundi Peru I n d o n e s i a Tanzania B r a z i l Papua New Guinea Solomon Islands East Timor Angola Zambia Bolivia Namibia Chile Laos Thailand Yemen Dijbouti Nigeria Gabon Bhutan Bangladesh India Oman Equatorial Guinea Ecuador Nepal Pakistan Saudi Arabia Mauritania Nicaragua Costa Rica Kuwait Bahrain Qatar U.A.E. Egypt (Occupied by Morocco) Dom. Rep. Puerto Rico Jamaica Honduras Libya Western Sahara Bahamas Mexico Somoa Malawi Vanuatu Fiji Zimbabwe Mauritius Mozambique Tonga Botswana Paraguay Swaziland Lesotho Madagascar A u s t r a l i a South Africa Argentina Uruguay New Zealand Schischek GmbH – Langenzenn / Germany Rotork - Schischek Sales Contact Your local dealer Headquarter/ Manufacturing Schischek GmbH Mühlsteig 45 Gewerbegebiet Süd 5 90579 Langenzenn Germany Tel. +49 9101 9081- 0 Fax +49 9101 9081-77 [email protected] www.schischek.com To find your local contact please visit: www.schischek.com/contact/schischek-worldwide www.rotork.com/en/contact/index/ PUB113- 001- 00_0514 www.schischek.com AP Automatyka | +48 67 357 10 80 | [email protected] | www.apautomatyka.pl
Podobne dokumenty
HOUSE ELECTRICAL INSTALLATIONS OBZOR Production Cooperative Zlin
Dimensions (h x w x d) mm Temperature range
Bardziej szczegółowo