1 2 S-MIX A radio receiver operating manual 1 2 1 2
Transkrypt
1 2 S-MIX A radio receiver operating manual 1 2 1 2
S-MIX A radio receiver operating manual Fig.2 S-MIX card installation DIODA SYGNALIZACYJNA PP PRZYCISK KANA£ PP DIODA SYGNALIZACYJNA FU PRZYCISK KANA£ FU II. Technical data 4 Cooperate with DTM, NICE and KeeLoq coding remotes of other producers 4 Cooperate with NICE gate controllers compatible with SMILO 4 Superheterodine receiver, work frequency 433,93MHz 4 Memory up to 35 remotes 4 Easy remote registering without need of using receivers buttons – only available if using DTM remotes 4 Possibility to lick easy remote registering function 4 Radio card supply from gate controller 4 Max current constription 15mA ; 4 Working temperature -20°C do +55°C; 4 Dimensions: 42mm x 33mm x 10mm. IV. S-MIX programming 1. Remote registering Fig. 5 Radio card scheme with main functions Fig.3 Remote registering (channel 1) 2. Easy remote registering Remotes must be in radio range of receiver. 1 2 2 1 CZAS I. Main information Radio card S-MIX is devoted for NICE gate controllers. It has two output channels. It is compatible with DTM radio remotes and almost all remotes with KeeLoq coding of other producers. Working with DTM remotes dynamically variable code Keeloq gives high class safety. push and hold C1 button + push remote button Hold any of already assigned remote button for 15 sec III. Radio card installation max break period 3sec hold any button of “new” remote for 15 sec Fig.6 Easy remote registering Fig.4 Remote registering (channel 2) “New” remote has same configuration as already assigned one. 1 Easy registering is available only for DTM remotes. 2 3 2 push and hold C2 button NICE + push remote button CZAS 1 S-MIX Fig. 1. S-MIX card installation in original case. Caution! Unsuccessful remote registering may be caused by: 4 low battery of any of remotes 4 radio interference from other sources 4 lock of easy remote registering function (point 4) 4 using other than DTM remote in registering 3. Remote button function change 4 remove remote from card memory (point 5) 4 register remote again (point 1 or 2) * while programming it is allowed to use any of remote buttons. Channel 1 and Channel 2 functions must be programmed in gate controller. 4. Easy remote registering function lock/unlock 5.Remote removing MAX. 3 SEK. 2 11 DEKLARACJA ZGODNOŒCI While holding... MIN. 5 SEK. 2 ...push the remote button 1 Nr 03/2016 Producent DTM System spó³ka z ograniczon¹ odpowiedzialnoœci¹ sp.k. ul.Brzeska 7, 85-145 Bydgoszcz, Polska Wyrób Karta zdalnego sterowania radiowego, model(e): S-MIX, S-FIX, SPC433 Fig.8 Single remote removing Caution! If you hold receivers button for more than 10 sec it may cause receiver’s memory format and removing all the remotes Locked Opis wyrobu Karta radiowa zdalnego sterowania o kodowanej transmisji, p o s i a d a j ¹ c a 2 k a n a ³ y, p r a c u j ¹ c a n a c z ê s t o t l i w o œ c i 433,92 Mhz. Zasilana z p³yty g³ównej sterownika. Do sterowania kart¹ s³u¿¹ bateryjnie zasilane piloty (nadajniki) radiowe, Urz¹dzenie przeznaczone jest do wspó³pracy z centralami bramowymi. 6. All remotes removing Unlocked Wyrób jest zgodny z Dyrektywami Unii Europejskiej: R&TTE 99/5/EC 3 1 SPRZÊT RADIOWY W KLASIE 1 WED£UG R&TTE min.15 sec Locked 4a Unlocked Fig.9 Remotes removing 4b Caution! While formatting receiver memory all remotes will be removed and easy remote registering function will be unlocked. V. DTM433MHz remote parameters Fig.7 Easy remote registering function on/off To secure device from unwanted remote registering (aspecial protected customers areas) it is recommended to lock easy r e m o t e r e g i s t e r i n g f u n c t i o n . To lock easy remote registering function push and hold simultaneously both of buttons. Than release one of the buttons (any of two buttons, the other one must be pushed till the procedure is finished). After 4 seconds C1 diode will light (means that easy remote registering function is unlocked). Still hold the button, after another 4 seconds C2 diode will light (means that easy remote registering function is locked). After releasing the button card will remember the settings and easy remote registering function will be locked. Same procedure is to unlock easy remote registering, just release the button when C1 diode light. By default – factory settings, easy remote registering function is locked. 4 four (two) buttons that can control any channel or the group channels 4 signal transmission is based on Microchips® KeeLoq® dynamically variable code, 4 remote frequency 433,92 Mhz 4 up to 150m radio range NEO, 50m TIP 4 battery: L1028 23A 12V, 4 ERP TIP: 1 mW, NEO: 3 mW; 4 working temperature from 0°C to +55°C. 4 four (two) buttons that can control any channel or the group channels 4 signal transmission is based on Microchips® KeeLoq® dynamically variable code, 4 remote frequency 433,92 Mhz VI. Warranty DTM System checks all the devices before shipping. The warranty time is 24 months from the selling date. This time is counted according to the warranty label. The manufacturer will fix all the problems which come because of his fault. Non functioning device should be delivered back to the distributor with short problem description. The cost of mount/dismount is covered by user. The warranty do not cover: batteries in the remotes, faults caused by improper usage, user self repairs and adaptations, lightning strikes, over voltages or short circuits in the mains supply. Appropriate legal acts regulates details of the warranty. Wyrób spe³nia wymagania norm zharmonizowanych: R&TTE: PN-ETSI EN 300 220-2 V2.1.2:2007; PN-ETSI EN 300 220-3 V1.1.1:2004 EMC: PN-EN 301 489-1; PN-EN 301 489-3 Procedura oceny zgodnoœci W kartach radiowych przeprowadzono wewnêtrzn¹ kontrolê produkcji zgodnie z za³¹cznikiem II dyrektywy R&TTE 99/5/EC. Wyniki potwierdzaj¹ zgodnoœæ. Zgodnoœæ dla przedmiotowego wyrobu lub pochodnych potwierdzaj¹ równie¿ badania w Instytucie £¹cznoœci, Szachowa 1, PL 04-894 Warszawa Bydgoszcz, Polska 08-02-2016 Prezes Zarz¹du Komplementariusza Daniel Kujawski The intention of the WEEE Directive (Directive 2002/96/EC on waste electrical and electronic equipment) is to reduce the amount of hazardous substances in waste. The underlying purpose is to promote the avoidance, recovery and risk-free disposal of waste. DTM System spó³ka z ograniczon¹ odpowiedzialnoœci¹ spó³ka komandytowa ul. Brzeska 7, 85-145 Bydgoszcz tel./fax +48 52 340 15 83, 52 340 15 84 www.dtm.pl [email protected]