sinline - EVER Sp. z o.o.
Transkrypt
sinline - EVER Sp. z o.o.
PRODUCT CHARACTERISTICS SINLINE 800, 1200, 1600, 2000, 3000 The next generation SINLINE-series battery back-ups enable full protection of power supply to advanced single- and multi CPU servers, PCs, computer termi nals and small and medium networks. - CBC – Cool Battery Charging – quick and efficient charging system that cuts charging time and extends the operating life of the back-up's accumulators SAFEGUARDS FEATURES - Communication interface RS232 - AVR – automatic mains voltage regulation system - Telecommunication filter - PowerSoft Personal – monitoring software ensuring complete control over computer workstations - Technical support – 48h door-to-door service The SINLINE series is equipped with unique systems developed by EVER engineers: - CDS – Clear Digital Sinus – system that enables the battery back-up to generate true sine wave output voltage in battery operation mode www.ever.eu - Against overloads - Against shorting - Against overvoltage - Against incorrect connection SINLINE MODEL 800, 1200, 1600, 2000, 3000 SINLINE 800 Output power (apparent/active) 1) 800VA/520W Technology Case type MAINS OPERATION MODE Input voltage 2) Frequency of input voltage Range of output voltage 2) Shape of output voltage Switching thresholds: mains - UPS 2) Time to switch to UPS Filtering of output voltage BACK-UP (BATTERY) OPERATION MODE Output voltage Frequency of output voltage Shape of output voltage Switching thresholds: UPS – mains 2) Switching time: UPS – mains Filtering of output voltage Shorting safeguard Overload protection UPS (100%/80%/50% Pmax) UPS + battery module Support time Warning! The manufacturer reserves the right to change the abovementioned parameters without notice. Accumulator capacity UPS charging time 3) UPS 5/7/12 min 2 x 12V 5Ah Battery module UPS 5h UPS + battery module SINLINE 1200 SINLINE 1600 SINLINE 2000 SINLINE 3000 1200VA/780W 1600VA/1040W 2000VA/1300W 3000VA/1950W line-interactive (VI) Tower ~160 - 264V (~145 - 280V) ± 2% 45 - 55Hz ± 1Hz ~184 - 264V (~167 - 280V) ± 2% same as input but filtered ~160V / 264V (~145V / 280V) ± 2% <3 ms noise filter RFI-EMI varistor damper ~230V ± 5% 50Hz ± 1Hz sinus ~165V / ~259V (~150V / ~275V) ± 2% 0 ms LC Electronic Electronic 4/5/8 min 4/5/9 min 4,5/6/10 min 2 x 12V 7Ah 3 x 12V 5Ah 4 x 12V 5Ah 7h 5h 5h - 3/4/8 min 4 x 12V 7Ah 7h MECHANICAL PARAMETERS Dimensions in [mm] UPS (h x w x d) Battery module Weight UPS Battery module ENVIRONMENTAL PARAMETERS Working environment Operating / storage temperature 4) Relative humidity for operation / storage Altitude above sea level 5) EQUIPMENT Number and type of outlet sockets Signalling Overcurrent protection Telephone line / LAN filter Communication interface Software 14kg 190 x 165 x 480 16kg 20kg - 190x165x640 23kg 28kg Rooms with low level of pollution +10oC - +35oC / 0oC - +45oC 20 - 80% / 20 - 95% (without condensation) up to 1000m 4 x PL sound and LED fuse circuit breaker +/RS 232 PowerSoft Personal 1) For normal operation of the battery back-up the load connected to its output should not exceed 80% of value indicated in the table. Reserve power is essential to ensure continuous operation of connected devices in case of momentary rushes in load current. 2) User may modify the switching thresholds within the range provided. Default setting is provided in parentheses. 3) After discharging the UPS with 0.8 Pmax power – charging the battery to 90% capacity. 4) Continued exposure of the battery back-up to the ambient temperature exceeding +25°C will shorten the life of batteries. 5) If the altitude above sea level increases beyond the provided limit the permitted load power of the batter back-up decreases. SINLINE 800, 1200, 1600, 2000, 3000 FRONT PANEL 1) A column of green LEDs indicating the charge level of the accumulator. 2) Power switch 3) LED indicating whether the AVR (Automatic Voltage Regulation) system is engaged 4) Two-colour LED indicating the operating mode: a. mains operation mode b. battery operation mode 5) A column of LEDs (three green, top one red) indicating the load of the battery back-up in percents. REAR PANEL 6) Outlet sockets 7) Port for communication with a PC via RS232 8) Telecommunication filter sockets RJ 11 9) Power cord 10) Cut-out (fuse in back-ups with power of 800VA, 1200VA and 1600VA; circuit breaker in back-ups with power of 2000VA and 3000VA) EVER Sp. z o.o. ul. Grudziñskiego 30, 62-020 Swarzêdz tel. 0048 61 6500 400, fax 0048 61 6510 927, e-mail: [email protected]