WSZCZEPY PGLA+HAP

Transkrypt

WSZCZEPY PGLA+HAP
BIOMIMETIC FIBROUS COMPOSITE MEMBRANES FOR BONE TISSUE ENGINEERING
Izabella Rajzer1*, Wojciech Chrzanowski2, Włodzimierz Biniaś1, Ewa Sarna1, Jarosław Janicki1
1
ATH, University of Bielsko-Biala,
Faculty of Materials and Environmental Sciences,
Institute of Textile Engineering and Polymer Materials, Department of Polymer Materials,
Willowa 2, 43-309 Bielsko-Biała, Poland
2
University of Sydney, The Faculty of Pharmacy,
Bank Building A15, Sydney, NSW 2006, AUS
* e-mail: [email protected]
Abstract
One of the major challenges in biomaterials and tissue engineering is to guide the cell differentiation to the specific
phenotype, therefore allow the formation of the tissue of certain type. This can be achieved by manipulating the structural,
geometrical and chemical characteristics of the tissue engineering constructs.
In our studies we concentrated on the chemical modifications of the polymer based materials for tissue engineering. The
primary aim of our study was to incorporate nano size hydroxyapatite (n-HAp) crystals into the polymer fibres and form
membranes, which are a core to the construction of novel scaffolds for tissue regeneration. We hypothesised that n-HAp will
significantly improve the bioactivity of the polymer based membranes due to the presence of chemical cues.
We developed a simple method to fabricate PLDL/n-HAp composite membranes using electrospinning process. The
investigation showed that the incorporation of the n-HAp particles in the polymer spinning solution induced changes in the
material surface morphology. FTIR analysis confirmed the presence of apatite on the surface of the membrane’ fibers. The
bioactivity analysis, which was based on SEM observation of the membranes surface, showed that after only 7 days
immersion in SBF, the PLDL/n-HAp –membranes were completely covered by the apatite layer. This was not observed for
pure PLDL membranes.
[Engineering of Biomaterials/Inżynieria Biomateriałów, 93, (2010), 2-5]
MECHANICAL PROPERTIES OF CARBON/HYDROXYAPATITE NONWOVENS
FOR BONE TISSUE ENGINEERING
Izabella Rajzer1, Wojciech Piekarczyk2, Joanna Grzybowska-Pietras1, Jarosław Janicki1
1
ATH, University of Bielsko-Biala,
Faculty of Materials and Environmental Sciences,
Institute of Textile Engineering and Polymer Materials,
Department of Polymer Materials
Willowa 2, 43-309 Bielsko-Biała, Poland
2
AGH University of Science and Technology,
Faculty of Materials Science and Ceramics,
Department of Advanced Ceramics,
Al. Mickiewicza 30, 30-059 Kraków, Poland
* e-mail: [email protected]
[Engineering of Biomaterials/Inżynieria Biomateriałów, 93, (2010), 6-9]
OCENA PRZYDATNOŚCI MATERIAŁÓW
POLIMEROWYCH NA IMPLANTY KRĘGOSŁUPOWE
NA PODSTAWIE BADAŃ POST MORTEM NA
KOZACH
EVALUATION OF THE USEFULNESS OF
POLYMERIC MATERIALS FOR SPINAL
IMPLANTS ON THE BASIS OF POST MORTEM
STUDIES ON GOATS
Lechosław F. Ciupik1, Agnieszka Kierzkowska1,2, Jacek Sterna3
1
Centrum Badawczo-Rozwojowe,
Research & Development Center,
Instytut Bioinżnierii Medycznej, LfC,
Institute of Bioengineering, LfC,
ul. Kożuchowska 41, 65-364 Zielona Góra
41 Kożuchowska str. Zielona Gora
2
2
Uniwersytet Zielonogórski, Wydział Mechaniczny,
University of Zielona Gora,
Instytut Budowy i Eksploatacji Maszyn,
Faculty of Mechanical Engineering,
ul. Podgórna 50, 65-246 Zielona Góra
Institute of Mechanical Engineering
3
SGGW-AR, Wydział Medycyny Weterynaryjnej,
and Machine Operation,
Katedra Chorób Małych Zwierząt z Kliniką,
50 Podgorna Str., 65-246 Zielona Gora
3
ul. Nowoursynowska 159 , 02-776 Warszawa
Warsaw University of Life Sciences-SGGW,
Faculty of Veterinary Medicine,
Department of Small Animal Diseases with Clinic,
159 Nowoursynowska str., 02-776 Warsaw
1
Słowa kluczowe: polimer, badania na zwierzętach,
biozgodność, implant kręgosłupowy
Keywords: polymer, animal studies, biocompatibility,
spinal implant
[Engineering of Biomaterials/Inżynieria Biomateriałów, 93, (2010), 10-13]
TECHNOLOGICZNO-BIOMECHANICZNA OCENA
TECHNOLOGY-BIOMECHANICAL EVALUATION
BIOMATERIAŁÓW METALOWYCH
OF METAL BIOMATERIALS DERIVED BY LAYER
OTRZYMYWANYCH TECHNOLOGIĄ WARSTWOWĄ
TECHNOLOGY
1
1,2
Lechosław F. Ciupik , Agnieszka Kierzkowska
1
1
Centrum Badawczo-Rozwojowe,
Research & Development Center,
Instytut Bioinżynierii Medycznej, LfC,
Institute of Bioingeering, LfC,
ul. Kożuchowska 41, 65-364 Zielona Góra
41 Kożuchowska str. Zielona Gora
2
2
Uniwersytet Zielonogórski, Wydział Mechaniczny,
University of Zielona Gora,
Instytut Budowy i Eksploatacji Maszyn,
Faculty of Mechanical Engineering,
ul. Podgórna 50, 65-246 Zielona Góra
Institute of Mechanical Engineering
and Machine Operation,
50 Podgorna Str., 65-246 Zielona Gora
Słowa kluczowe: implant, stapianie elektronowe proszków
stopów tytanu, biomechanika
Keywords: implant, electron beam melting of titanium
alloy powder, biomechanics
[Engineering of Biomaterials/ Inżynieria Biomateriałów, 93, (2010), 14-18]
NAPRĘŻENIA WŁASNE W WARSTWACH
THE RESIDUAL STRESS IN CARBON FILMS
WĘGLOWYCH OSADZANYCH NA PODŁOŻU
DEPOSITED ON TITANIUM SUBSTRATES
TYTANOWYM
Rafał Raczkowski, Mariusz Dudek*
Politechnika Łódzka,
Technical University of Lodz,
Instytut Inżynierii Materiałowej,
Institute of Materials Science and Engineering,
ul. Stefanowskiego 1/15, 90-924 Łódź
Stefanowskiego 1/15, 90-924 Lodz, Poland
* e-mail: [email protected]
* e-mail: [email protected]
Streszczenie
Abstract
Wysokie naprężenia ściskające występujące w warstwach
węglowych znacząco ograniczają ich grubość, gdyż prowadzą
do jej delaminacji. W prezentowanej pracy zbadano wpływ
ujemnego potencjału autopolaryzacji na wartość naprężeń
występujących w warstwach węglowych wytworzonych na
tytanowym podłożu podczas procesu RF PECVD. Otrzymane
wyniki pokazują, że metoda pomiaru naprężeń oparta na
zależności Stoney’a pozwala na dokładne pomiary naprężeń w
przypadku warstw osadzanych na wybranym podłożu.
Maksimum naprężeń ściskających jest obserwowane dla
małych wartości potencjału autopolaryzacji (-300 V) i stale
maleje wraz ze wzrostem napięcia. W przedziale od -500 V do
-600 V mierzone naprężenia zmieniają się z naprężeń
ściskających na rozciągające. Po zmianie znaku naprężenia w
warstwie wzrastają wraz z wartością potencjału
autopolaryzacji. Wpływ mikrostruktury na naprężenia
wewnętrzne w warstwach był analizowany przy użyciu
spektroskopii Ramana.
High compressive stress present in carbon films
significantly limits their thickness because of delamination.
In this work, the effect of substrate bias on the amount of
stress in carbon films deposited on titanium substrate by the
RF PECVD technique was investigated. The results
obtained show that the Stoney formula provides a very
convenient and accurate way to measure the stress in the
case of films deposited on selected substrates. The
maximum of compressive stress is observed at low bias
voltage (-300 V) and it steadily decreases with the
increasing value of this voltage. In the range from -500 V to
-600 V the measured stress changes from compressive to
tensile and it continuously increases with further bias
increase. The effects of the film microstructure on the
film’s internal stress were also studied using Raman
spectroscopy.
Keywords: RF PECVD, carbon film, stress
Słowa kluczowe: RF PECVD, warstwy węglowe, naprężenia
[Engineering of Biomaterials/Inżynieria Biomateriałów, 93, (2010), 19-24]