Opis typoszeregu: Wilo-EMUport FTS
Transkrypt
Opis typoszeregu: Wilo-EMUport FTS
Opis typoszeregu: Wilo-EMUport FTS Rysunek podobny Budowa Opis/budowa Customizable sewage lifting unit with solids separation system for installation in a building or in a pump chamber for outdoor installation. Fully submersible sewage lifting unit ready for connection with solids separation. All-in-one gastight and watertight collection reservoir without constructive welded joints, as well as two separately-lockable solids separation reservoirs. The collection reservoir has rounded edges and the bottom of the basin is bevelled. This prevents deposits and the drying of solids. With pre-filtering in the solids separation reservoirs, the solids are filtered from the fluid and only pre-filtered sewage is directed to the collection reservoir. Pumping is performed by two high-performance submersible sewage pumps in versions IP55 or IP68 in dry well installation. The pumps are designed as a redundant double-pump system and run in alternating operation. Level management can be performed via three float switches or a level probe. Oznaczenie typu Example: FTS F G 1500 Wilo-EMUport FTS MG 1500 Solids separation system (custom version) Version (M = compact version, F = large version) Type of installation (G = in building, S = with PE-HD pump chamber) FG = outer diameter of the collection reservoir in mm FS = shaft diameter in mm MG = installation depth below inlet floor in mm MS = shaft inside diameter in mm Zastosowanie Pumping of untreated sewage that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level (according to DIN EN 12056/ DIN 1986-100). On request, the system can be equipped with automatic backflushing to the collection reservoir and installed directly into a pump chamber made of PEHD. For management, the corresponding switchgear of the SC-L and CC-L series can be selected as an accessory. Materiały Collection reservoir: PE-HD Solids separation reservoir: PE-HD Pipework: PE-HD Valves: Cast iron Pumps: Cast iron Pump chamber: PE-HD (for systems FTS MS and FTS FS) Cechy szczególne/zalety produktu Maksymalnie niezawodne działanie dzięki separacji substancji stałych od ścieków: Duże ciała stałe nie muszą przepływać przez pompę – brak zatoru Ekonomiczność dzięki systemowi Retrofit zapewniającemu prostą renowacją starych przepompowni Długa żywotność i brak podatności na korozję dzięki zastosowaniu materiału PE-HD Elastyczne skalowanie zgodnie z indywidualnymi wymaganiami Prosta konserwacja zapewniona przez higieniczne ustawienie na sucho i łatwy dostęp z zewnątrz Możliwość elastycznego montażu w budynku lub w studzienkach o średnicy od 1500 mm Oszczędność energii dzięki dostępnym w ramach opcji pompom zatapialnym do ścieków z silnikami IE3 Dane techniczne Max. inlet: FTS M…: 35 m³/h; FTS F…: 600 m3/h Max. useable tank volume: FTS M…: 700 l; FTS F…: 12000 l Max. delivery head: FTS M…: 50 m; FTS F…: 80 m Installation depth below inlet floor: 400...2300 mm Mains connection: 3~400 V, 50 Hz, Wyposażenie/funkcja Sewage lifting unit with solids separation system Two solids separation reservoirs that can be shut off individually Two dry-well installed submersible sewage pumps for alternating mode Pumps in protection class IP55 or IP68 Also with IE3 motors Level measurement according to customer request Zakres dostawy Installation-ready sewage lifting unit Two sewage pumps Individual shut-off of the solids separation reservoirs Discharge pipe junction with smooth pipe end Valves Opcje Other reservoir sizes and suction heads can be produced as requested by the customer, e.g. due to existing installation openings or door dimensions. Inductive flow rate measuring instrument with slide valve Switchgear with level measurement Lighting Slide valve for inlet Flange outlet for inlet and discharge pipeline Flush connection Konfiguracja The installation must be configured for the maximum amount of sewage occurring, including a possible additional peak flow. The pumps must be configured for a minimum flow velocity of 0.7 m/s in the discharge pipeline (e.g. min. 18.55 m³/h for a DN 100 pipe). The manometric delivery head is calculated as the maximum geodesic head + pipeline friction losses + pumping station losses. 06.02.2017, Kraj: Polska (Poland), Język: polski (polish) 1/4 Rodzina charakterystyk: Wilo-EMUport FTS 06.02.2017, Kraj: Polska (Poland), Język: polski (polish) 2/4 Wyposażenie/funkcje: Wilo-EMUport FTS Konstrukcja Pompa objęta zakresem dostawy Układ jednopompowy Układ dwupompowy W studzience PE-HD • • • Zastosowanie Instalacja nad podłogą Instalacja pod podłogą • • Wyposażenie/Funkcja Urządzenie sterujące º Łagodny rozruch Opcjonalnie Przetwornica częstotliwości º Wyłącznik różnicowo-prądowy º Sterowanie poziomem za pomocą pneumatycznego czujnika ciśnienia Sterowanie poziomem: za pomocą czujnika poziomu • Transmisja danych: za pośrednictwem przewodu º Transmisja danych: za pośrednictwem modułu GSM/UMTS º Awaryjne przyłącze sieciowe º Dowolny wybór położenia dopływu • Gotowe do podłączenia Szafa sterownicza do ustawienia na zewnątrz º • = available, - = not available; º = optional 06.02.2017, Kraj: Polska (Poland), Język: polski (polish) 3/4 Rysunki instalacyjne: Wilo-EMUport FTS 06.02.2017, Kraj: Polska (Poland), Język: polski (polish) Powered by TCPDF (www.tcpdf.org) 4/4