brise - Jaga

Transkrypt

brise - Jaga
BRISE
Brochure € 2012-2013.EX
BRISE
Super-power for heating,
cooling and ventilation.
Brise keeps a tight rein on temperatures and is
full of energy, controlling your interior climate
with precision through the range of activator
controlled settings. Heating. Ventilating.
Cooling. Regardless, this radiator is always in
pole position, ready to win the race for comfort.
Flexible application.
For climate control in shops, offices, schools,
hotels, conference rooms, conservatories, etc...
High comfort with efficient energy use
Due to its very low water content and high capacity
Jaga fan convectors react immediately to strong
temperature changes.
Perfect design
The Brise is not only a technically superb product,
it distinguishes itself also by a stylish design and
impeccable finish, which makes it blend into any
interior design.
Suitable for non-condensing
and condensing cooling with
chilled water
316
317
BRISE
BRISE WALL MOUNTED MODEL
DIMENSIONS (in cm)
BRIW/BRIF
Speed control 0 - 3 - 2 - 1
B
A
D
C
17
9.8
7
10
11
6
G
10
9
8
6.8 22.7
10
Ø2
min
10
16.5
8
9.5
4
9.5
F
E
2
8
3
4
52.5
12
1
BrIF = BrIW + feet + rear panel.
Feet equipped with cover plate for the electrical
and hydraulic connections.
BUILDING-IN BRBW
12.5
min. 10
B
D
1
10
E
50
1
2
F
8
3
6.8 22.7
12 8.5
C
H
G
1
10
9
min
10
Type
A
B
C
D
E
F
G
H
I
conn. heat exchanger
conn. air vent
02
82.5
23.0
4.5
5.3
45.5
25.5
55.7
57.5
36.5
1/2" G
1/8"
03
82.5
23.0
4.5
15.3
45.5
25.5
55.7
57.5
36.5
1/2" G
1/8"
ORDERING CODE
code
type
BRIW .
02
fill in type
318 |
10
Ø2
jaga Top Performers
8
04
110.0
23.0
4.5
15.3
45.5
25.5
83.2
85.2
36.5
1/2" G
1/8"
06
110.0
23.0
4.5
15.3
45.5
25.5
83.2
85.2
36.5
3/4" G
1/8"
08
137.5
27.5
4.5
22.5
46.3
26.0
110.7
112.7
41.0
3/4" G
1/8"
10
165.0
27.5
4.5
22.5
46.3
26.0
138.2
140.2
41.0
3/4" G
1/8"
The model BrBW can be fitted horizontally for
heating only.
Provide an air vent on the central heating pipe
work.
1.
2.
3.
4.
5.
6.
7.
8.
9.
heat exchanger
condensation tray
Fan(s)
not recyclable air filter (option)
air exhausting grille
switch
additional condensation tray (option)
casing
holes for wall fixing
STANDARD DELIVERY
HYDRAULIC CONNECTION
easy to install, pre-assembled fan radiator,
supplied in a handy cardboard box. Type BrIW/
BrIF and BrBW with metal casing with smooth
metallic paint in light grey and discharge vents
in dark grey ABS (Acrylonitrile Butadiene Styrene).
Standard delivery includes:
- centrifugal fan(s) engine to condense in 3
speeds continuously and integrated KLIXoN
security with an automatic reset.
- re-usable air filter with galvanised chassis for
the BrIW and BrIF models
- built-in 3-position speed controller for the
BrIW and BrIF models
- condensation tray with drain
Standard connection left
- type 02, 03 and 04: 1/2”
- type 06, 08 and 10: 3/4”
connection right on request:
connection condensation drain pipe ø 2 cm
ELECTRIC CONNECTION
electric connection 230 VAc always right
€ EX - 29/08/12
CEILING-MOUNTED MODEL BRISE
DIMENSIONS (in cm)
A
E
52.5
2 1 9 6
3.8
9.8
6
10
10
10
11
5 4 3
G
6.8
17
6 11
22.7
F
12
(*) 0.5 > 1.5 cm
C
D
B
WITH CASING BRIC
Max. height of the ceiling: 2.80 m.
(*) Fit the ventilo-fan convector at a slight
upward angle to facilitate the drainage of the
condensation water.
The model BrIc or BrBc may also be fitted
vertically, it is only to be used for heating.
Provide an air vent on the central pipe work .
BUILDING-IN BRBC
4 3
1 2
(*) 0.5
1.5 cm
C
D
I
13.5
E
50
option corner piece and air
exhausting grille
option air inlet grille
C
1.5 cm
(*) 0.5
min
10
F
4 3
€ EX - 29/08/12
11.4
11
15.7
D B
50
F
8.5 12 22.7 6.8
19
23.2
H
G
4.7
10
10
10
option air inlet grille: do not mount it too close
to the Brise to avoid the possibility that the
exhausted hot air will be sucked in again.
Max. height of the ceiling: 2.80 m.
(*) Fit the ventilo-fan convector at a slight
upward angle to facilitate the drainage of the
condensation water.
The model BrIc or BrBc may also be fitted
vertically, it is only to be used for heating.
Provide an air vent on the central pipe work .
E
50
1
2
jaga Top Performers
| 319
BRISE
Ordering example: BRIW. type
STANDARD HEAT EXCHANGER
HEATING
kW
75/65/20°C
kW
55/45/20°C
kW
35/30/20°C
max. med. min.
max. med. min.
max. med. min.
COOLING
kW total
7/12°C - 25°C D.B.
50% R.H.
max. med. min.
kW sensible
7/12°C - 25°C D.B.
50% R.H.
max. med. min.
wall
casing
BRIW
€
con.
BRBW
€
ceiling
casing
BRIC
€
con.
BRBC
€
freestanding
casing
BRIF
€
TYPE
02
03
04
06
08
10
4.00
5.56
8.07
11.53
19.48
21.02
3.60
5.00
7.26
10.38
16.78
18.92
3.04
4.22
6.13
8.76
14.17
15.97
2.40
3.34
4.84
6.92
11.69
12.61
2.16
3.00
4.36
6.23
10.07
11.35
1.82
2.53
3.68
5.26
8.50
9.58
1.00
1.39
2.02
2.88
4.87
5.26
0.90
1.25
1.82
2.60
4.20
4.73
0.76
1.06
1.53
2.19
3.54
3.99
1.63
2.28
3.37
4.88
8.02
9.97
1.47
2.05
3.03
4.39
7.22
8.79
1.24
1.73
2.56
3.71
6.10
7.40
OPTION SECOND HEAT EXCHANGER B4
HEATING
kW
75/65/20°C
kW
55/45/20°C
kW
35/30/20°C
max. med. min.
max. med. min.
max. med. min.
1.16
1.67
2.40
3.50
5.80
6.90
1.04
1.50
2.16
3.15
5.22
6.21
0.88
1.27
1.28
2.66
4.41
5.24
875,80
889,00
1080,80
1196,20
1764,80
2247,70
776,10
790,10
951,70
1067,30
1599,70
2072,00
934,80
951,70
1167,10
1281,90
1910,60
2431,40
790,10
806,00
980,90
1096,40
1624,50
2078,20
1047,10
1060,30
1260,00
1375,40
1968,90
2463,20
SURCHARGE
Code
€
8721.5112
8721.5112
8721.5113
8721.5114
8721.5115
8721.5116
190,80
190,80
218,00
244,50
288,80
349,50
TYPE
02
03
04
06
08
10
2.57
2.57
3.45
5.06
7.71
9.58
2.85
2.85
3.83
5.63
9.22
10.65
2.17
2.17
2.92
4.28
7.01
8.09
1.71
1.71
2.30
3.38
5.53
6.39
1.54
1.54
2.07
3.04
4.63
5.75
1.30
1.30
1.75
2.57
4.21
4.85
0.71
0.71
0.96
1.41
2.31
2.66
0.64
0.64
0.86
1.27
1.93
2.40
0.54
0.54
0.73
1.07
1.75
2.02
options are fitted when fan convector and options are ordered together. With built-in options, delivery
time will be longer. With second heat exchanger B4, the standard heat exchanger has to be used for
cooling and the second heat exchanger B4 for heating.
a
b
Second heat exchanger
B4 for connection of warm
water
c
d
connection for cool water
320 |
jaga Top Performers
Type
a
b
c
d
02 03 04 06 08 10
9
9
9
9 9.5 9.5
19.8 19.8 19.8 19.8 24 24
28 28 28 28 31.5 31.5
48 48 48 48 48 48
€ EX - 29/08/12
TECHNICAL DATA
AIR FLOW*
MAX. MEASURED
POWER
RAITED
CURRENT
m3/h
Watts
A
max. med.
min.
380 295
500 390
700 545
880 690
1350 1050
1700 1325
220
290
410
510
720
955
HOT AIR
WATER CONTENT
CARRYING*
STANDARD
m
litre
heat exchanger
Standard
B4
WEIGHT
kg
casing
wall
ceiling
con. casing
con.
TYPE
02
03
04
06
08
10
45
68
103
125
193
210
0.21
0.32
0.48
0.59
0.92
0.99
4
6
7
9
7
11
0.66
0.86
1.34
1.96
3.75
4.03
0.21
0.27
0.44
0.65
1.24
1.34
18.0
19.0
24.0
26.0
38.0
50.0
14.0
14.5
15.0
20.5
33.0
43.5
18.0
19.0
24.0
26.0
38.0
50.0
14.5
15.0
20.0
22.0
33.0
43.5
* Measured with clean filter.
TECHNICAL DATA - SOUND
SOUND PRESSURE*
dB(A) / NR
max.
med.
min.
SOUND POWER LEVEL ISO 23741/2
HZ 125
dB
max. med. min.
HZ 250
dB
max. med. min.
HZ 500
dB
max. med. min.
HZ 1000
dB
max. med. min.
HZ 2000
dB
max. med. min.
HZ 4000
dB
max. med. min.
HZ 8000
dB
max. med. min.
TYPE
02
03
04
06
08
10
41/36
41/36
44/39
50/46
50/45
53/30
35/31
35/31
36/32
37/33
37/33
43/38
29/25
29/25
30/26
31/27
43/38
37/33
48
52
49
53
55
58
45
46
44
45
49
50
42
42
38
38
45
46
46
52
50
55
57
60
44
45
43
44
50
51
39
40
38
39
43
46
46
42
47
49
51
55
40
36
37
37
44
46
35
30
31
32
35
40
42
47
49
51
51
55
36
37
37
38
44
46
30
31
32
34
35
40
37
44
39
46
47
53
30
31
30
30
39
44
23
23
24
25
30
34
32
40
36
41
43
47
26
27
26
27
36
38
23
22
21
22
27
29
25
37
33
37
34
39
24
26
25
27
30
29
20
20
20
21
21
27
* Measured model: model BrIW with casing, standard heat exchanger and a new filter. height: 1 m, 2 m from the air exhaust grille.
The sound level is influenced by the dimensions of the room, the reverberation time, other sound sources and the distance of the sound source.
€ EX - 29/08/12
jaga Top Performers
| 321
BRISE
OPTIONS
Filter
Wall mounting thermostat heating/
cooling
- LcD display
- Programmable in 8 half-days
- automatic or manual cooling / heating
changeover
- Ac 230 V, on / off or 3-position control
outputs
- speed control: automatic or manual
- operating modes: comfort, energy saving
and frost protection
- for 1 fan convector or 1 regulator for several
fan coils in combination with relay contacts
- for two pipe and four pipe fan convectors
8.6
8.6
CODE
8751.050005
4.4 1.3
€
192,50
recyclable air filter (standard at BrIW and
BrIF, option at BrIc, BrBW and BrBc)
CODE
8721.121
8721.125
8721.115
8721.116
type
02 - 03
04 - 06
08
10
BxL
21 x 53
21 x 80.5
25 x 108
25 x 135.5
€
37,05
47,65
64,60
74,75
Rear panel for model BRIW
For freestanding models order feet separately.
Condensation tray for model BRIW - BRIF
- BRBW
Additional condensation tray for cooling. Position underneath the valves.
CODE
type
8769.0041 02 - 03 - 04 - 06
8769.0023 08 - 10
€
28,25
28,25
Fan-seal panel for model BRBW - BRBC
For air intake on 1 side and as air-conducting
compartments.
Always order when using built in models.
Speed control / thermostat
7.5
Wall-mounted thermostat with on/off button
and manual 3-position speed controller. Suitable for heating, cooling and ventilation. For 1
unit or for several units, combined with relay
contacts.
12.8
CODE
8762.0000
2.9
€
247,20
CODE
8770.121
8770.125
8770.115
8770.116
type
02 - 03
04 - 06
08
10
€
85,70
93,65
118,30
129,90
CODE
8775.0021
8775.0025
8775.0015
8775.0016
type
02 - 03
04 - 06
08
10
€
27,40
38,00
48,40
55,65
Feet for model BRIW - BRBW
Includes protective cover.
Additional electric element
options are fitted when fan convector and
options are ordered together. With built-in
options, delivery time will be longer. Includes
security thermostat. Do not combine with 2nd
heat exchanger B4.
During the functioning of the electric element,
air flow has to be guaranteed.
electric connection 230 V - 1 f - 50 hz.
Surcharge
CODE
8721.6012
8721.6014
8721.6015
8721.6016
322 |
type
02 - 03
04 - 06
08
10
Nominal power
€
Watts
1000
2000
2000
2000
237,40
261,30
353,10
560,70
jaga Top Performers
CODE
8767.141
8767.123
type
02 - 03 - 04 - 06
08 - 10
€
85,70
85,70
€ EX - 29/08/12
OPTIONS
Fan-seal panel for model BRIC
For visible mounting. Seal panel in the same
colour as the radiator.
Plenum with 2 connections ø16 cm for
model BRBC
exhaust plenum for connection of two air channels. Maximum length of the channel 2 metre,
without loss of air flow.
A
CODE
8771.121
8771.125
8771.115
8771.116
type
02 - 03
04 - 06
08
10
€
57,55
57,55
63,65
73,20
Transformation to exhaust downwards
for model BRIC
Includes fan-seal panel for BrIc. Maximum
height of ceiling: 2.6 m. Maximum fitting
height: 2.3 m.
only available when ordering with the appliance
31
CODE
8764.0221
8764.0225
8764.0215
8764.0216
type
02 - 03
04 - 06
08
10
A
26.7
40.6
54.2
67.9
€
558,10
558,10
637,00
747,70
Plenum with connection ø31.5 cm for
model BRBC
exhaust plenum for connection of one air
channel . Maximum length of the channel 2
metre, without loss of air flow.
31
260
230
CODE
8774.0025
8774.0015
8774.0016
type
04 - 06
08
10
€
422,90
422,90
422,90
CODE
8764.0121
8764.0125
8764.0115
8764.0116
type
02 - 03
04 - 06
08
10
€
374,70
411,00
538,00
678,40
Air mixing box wall mounted model
Air mixing box ceiling-mounted model
1. Servo motor
2. Air mixing box
3. Air inlet grille
1. Air mixing box
2. corner piece with adjustable air exhausting
grille
3. Fan-seal panel
4. Adjustable air inlet grille
For detailed information and prices
of the parts see:
www.theradiatorfactory.com
L
1
2
3
2
€ EX - 29/08/12
3
4
1
jaga Top Performers
| 323
Jaga International - Verbindingslaan z/n - B-3590 Diepenbeek
T: +32 11 29 41 16 - F: +32 11 29 41 60 - [email protected]
your partner:
290812 - JAGA N.V.