brise - Jaga
Transkrypt
brise - Jaga
BRISE Brochure € 2012-2013.EX BRISE Super-power for heating, cooling and ventilation. Brise keeps a tight rein on temperatures and is full of energy, controlling your interior climate with precision through the range of activator controlled settings. Heating. Ventilating. Cooling. Regardless, this radiator is always in pole position, ready to win the race for comfort. Flexible application. For climate control in shops, offices, schools, hotels, conference rooms, conservatories, etc... High comfort with efficient energy use Due to its very low water content and high capacity Jaga fan convectors react immediately to strong temperature changes. Perfect design The Brise is not only a technically superb product, it distinguishes itself also by a stylish design and impeccable finish, which makes it blend into any interior design. Suitable for non-condensing and condensing cooling with chilled water 316 317 BRISE BRISE WALL MOUNTED MODEL DIMENSIONS (in cm) BRIW/BRIF Speed control 0 - 3 - 2 - 1 B A D C 17 9.8 7 10 11 6 G 10 9 8 6.8 22.7 10 Ø2 min 10 16.5 8 9.5 4 9.5 F E 2 8 3 4 52.5 12 1 BrIF = BrIW + feet + rear panel. Feet equipped with cover plate for the electrical and hydraulic connections. BUILDING-IN BRBW 12.5 min. 10 B D 1 10 E 50 1 2 F 8 3 6.8 22.7 12 8.5 C H G 1 10 9 min 10 Type A B C D E F G H I conn. heat exchanger conn. air vent 02 82.5 23.0 4.5 5.3 45.5 25.5 55.7 57.5 36.5 1/2" G 1/8" 03 82.5 23.0 4.5 15.3 45.5 25.5 55.7 57.5 36.5 1/2" G 1/8" ORDERING CODE code type BRIW . 02 fill in type 318 | 10 Ø2 jaga Top Performers 8 04 110.0 23.0 4.5 15.3 45.5 25.5 83.2 85.2 36.5 1/2" G 1/8" 06 110.0 23.0 4.5 15.3 45.5 25.5 83.2 85.2 36.5 3/4" G 1/8" 08 137.5 27.5 4.5 22.5 46.3 26.0 110.7 112.7 41.0 3/4" G 1/8" 10 165.0 27.5 4.5 22.5 46.3 26.0 138.2 140.2 41.0 3/4" G 1/8" The model BrBW can be fitted horizontally for heating only. Provide an air vent on the central heating pipe work. 1. 2. 3. 4. 5. 6. 7. 8. 9. heat exchanger condensation tray Fan(s) not recyclable air filter (option) air exhausting grille switch additional condensation tray (option) casing holes for wall fixing STANDARD DELIVERY HYDRAULIC CONNECTION easy to install, pre-assembled fan radiator, supplied in a handy cardboard box. Type BrIW/ BrIF and BrBW with metal casing with smooth metallic paint in light grey and discharge vents in dark grey ABS (Acrylonitrile Butadiene Styrene). Standard delivery includes: - centrifugal fan(s) engine to condense in 3 speeds continuously and integrated KLIXoN security with an automatic reset. - re-usable air filter with galvanised chassis for the BrIW and BrIF models - built-in 3-position speed controller for the BrIW and BrIF models - condensation tray with drain Standard connection left - type 02, 03 and 04: 1/2” - type 06, 08 and 10: 3/4” connection right on request: connection condensation drain pipe ø 2 cm ELECTRIC CONNECTION electric connection 230 VAc always right € EX - 29/08/12 CEILING-MOUNTED MODEL BRISE DIMENSIONS (in cm) A E 52.5 2 1 9 6 3.8 9.8 6 10 10 10 11 5 4 3 G 6.8 17 6 11 22.7 F 12 (*) 0.5 > 1.5 cm C D B WITH CASING BRIC Max. height of the ceiling: 2.80 m. (*) Fit the ventilo-fan convector at a slight upward angle to facilitate the drainage of the condensation water. The model BrIc or BrBc may also be fitted vertically, it is only to be used for heating. Provide an air vent on the central pipe work . BUILDING-IN BRBC 4 3 1 2 (*) 0.5 1.5 cm C D I 13.5 E 50 option corner piece and air exhausting grille option air inlet grille C 1.5 cm (*) 0.5 min 10 F 4 3 € EX - 29/08/12 11.4 11 15.7 D B 50 F 8.5 12 22.7 6.8 19 23.2 H G 4.7 10 10 10 option air inlet grille: do not mount it too close to the Brise to avoid the possibility that the exhausted hot air will be sucked in again. Max. height of the ceiling: 2.80 m. (*) Fit the ventilo-fan convector at a slight upward angle to facilitate the drainage of the condensation water. The model BrIc or BrBc may also be fitted vertically, it is only to be used for heating. Provide an air vent on the central pipe work . E 50 1 2 jaga Top Performers | 319 BRISE Ordering example: BRIW. type STANDARD HEAT EXCHANGER HEATING kW 75/65/20°C kW 55/45/20°C kW 35/30/20°C max. med. min. max. med. min. max. med. min. COOLING kW total 7/12°C - 25°C D.B. 50% R.H. max. med. min. kW sensible 7/12°C - 25°C D.B. 50% R.H. max. med. min. wall casing BRIW € con. BRBW € ceiling casing BRIC € con. BRBC € freestanding casing BRIF € TYPE 02 03 04 06 08 10 4.00 5.56 8.07 11.53 19.48 21.02 3.60 5.00 7.26 10.38 16.78 18.92 3.04 4.22 6.13 8.76 14.17 15.97 2.40 3.34 4.84 6.92 11.69 12.61 2.16 3.00 4.36 6.23 10.07 11.35 1.82 2.53 3.68 5.26 8.50 9.58 1.00 1.39 2.02 2.88 4.87 5.26 0.90 1.25 1.82 2.60 4.20 4.73 0.76 1.06 1.53 2.19 3.54 3.99 1.63 2.28 3.37 4.88 8.02 9.97 1.47 2.05 3.03 4.39 7.22 8.79 1.24 1.73 2.56 3.71 6.10 7.40 OPTION SECOND HEAT EXCHANGER B4 HEATING kW 75/65/20°C kW 55/45/20°C kW 35/30/20°C max. med. min. max. med. min. max. med. min. 1.16 1.67 2.40 3.50 5.80 6.90 1.04 1.50 2.16 3.15 5.22 6.21 0.88 1.27 1.28 2.66 4.41 5.24 875,80 889,00 1080,80 1196,20 1764,80 2247,70 776,10 790,10 951,70 1067,30 1599,70 2072,00 934,80 951,70 1167,10 1281,90 1910,60 2431,40 790,10 806,00 980,90 1096,40 1624,50 2078,20 1047,10 1060,30 1260,00 1375,40 1968,90 2463,20 SURCHARGE Code € 8721.5112 8721.5112 8721.5113 8721.5114 8721.5115 8721.5116 190,80 190,80 218,00 244,50 288,80 349,50 TYPE 02 03 04 06 08 10 2.57 2.57 3.45 5.06 7.71 9.58 2.85 2.85 3.83 5.63 9.22 10.65 2.17 2.17 2.92 4.28 7.01 8.09 1.71 1.71 2.30 3.38 5.53 6.39 1.54 1.54 2.07 3.04 4.63 5.75 1.30 1.30 1.75 2.57 4.21 4.85 0.71 0.71 0.96 1.41 2.31 2.66 0.64 0.64 0.86 1.27 1.93 2.40 0.54 0.54 0.73 1.07 1.75 2.02 options are fitted when fan convector and options are ordered together. With built-in options, delivery time will be longer. With second heat exchanger B4, the standard heat exchanger has to be used for cooling and the second heat exchanger B4 for heating. a b Second heat exchanger B4 for connection of warm water c d connection for cool water 320 | jaga Top Performers Type a b c d 02 03 04 06 08 10 9 9 9 9 9.5 9.5 19.8 19.8 19.8 19.8 24 24 28 28 28 28 31.5 31.5 48 48 48 48 48 48 € EX - 29/08/12 TECHNICAL DATA AIR FLOW* MAX. MEASURED POWER RAITED CURRENT m3/h Watts A max. med. min. 380 295 500 390 700 545 880 690 1350 1050 1700 1325 220 290 410 510 720 955 HOT AIR WATER CONTENT CARRYING* STANDARD m litre heat exchanger Standard B4 WEIGHT kg casing wall ceiling con. casing con. TYPE 02 03 04 06 08 10 45 68 103 125 193 210 0.21 0.32 0.48 0.59 0.92 0.99 4 6 7 9 7 11 0.66 0.86 1.34 1.96 3.75 4.03 0.21 0.27 0.44 0.65 1.24 1.34 18.0 19.0 24.0 26.0 38.0 50.0 14.0 14.5 15.0 20.5 33.0 43.5 18.0 19.0 24.0 26.0 38.0 50.0 14.5 15.0 20.0 22.0 33.0 43.5 * Measured with clean filter. TECHNICAL DATA - SOUND SOUND PRESSURE* dB(A) / NR max. med. min. SOUND POWER LEVEL ISO 23741/2 HZ 125 dB max. med. min. HZ 250 dB max. med. min. HZ 500 dB max. med. min. HZ 1000 dB max. med. min. HZ 2000 dB max. med. min. HZ 4000 dB max. med. min. HZ 8000 dB max. med. min. TYPE 02 03 04 06 08 10 41/36 41/36 44/39 50/46 50/45 53/30 35/31 35/31 36/32 37/33 37/33 43/38 29/25 29/25 30/26 31/27 43/38 37/33 48 52 49 53 55 58 45 46 44 45 49 50 42 42 38 38 45 46 46 52 50 55 57 60 44 45 43 44 50 51 39 40 38 39 43 46 46 42 47 49 51 55 40 36 37 37 44 46 35 30 31 32 35 40 42 47 49 51 51 55 36 37 37 38 44 46 30 31 32 34 35 40 37 44 39 46 47 53 30 31 30 30 39 44 23 23 24 25 30 34 32 40 36 41 43 47 26 27 26 27 36 38 23 22 21 22 27 29 25 37 33 37 34 39 24 26 25 27 30 29 20 20 20 21 21 27 * Measured model: model BrIW with casing, standard heat exchanger and a new filter. height: 1 m, 2 m from the air exhaust grille. The sound level is influenced by the dimensions of the room, the reverberation time, other sound sources and the distance of the sound source. € EX - 29/08/12 jaga Top Performers | 321 BRISE OPTIONS Filter Wall mounting thermostat heating/ cooling - LcD display - Programmable in 8 half-days - automatic or manual cooling / heating changeover - Ac 230 V, on / off or 3-position control outputs - speed control: automatic or manual - operating modes: comfort, energy saving and frost protection - for 1 fan convector or 1 regulator for several fan coils in combination with relay contacts - for two pipe and four pipe fan convectors 8.6 8.6 CODE 8751.050005 4.4 1.3 € 192,50 recyclable air filter (standard at BrIW and BrIF, option at BrIc, BrBW and BrBc) CODE 8721.121 8721.125 8721.115 8721.116 type 02 - 03 04 - 06 08 10 BxL 21 x 53 21 x 80.5 25 x 108 25 x 135.5 € 37,05 47,65 64,60 74,75 Rear panel for model BRIW For freestanding models order feet separately. Condensation tray for model BRIW - BRIF - BRBW Additional condensation tray for cooling. Position underneath the valves. CODE type 8769.0041 02 - 03 - 04 - 06 8769.0023 08 - 10 € 28,25 28,25 Fan-seal panel for model BRBW - BRBC For air intake on 1 side and as air-conducting compartments. Always order when using built in models. Speed control / thermostat 7.5 Wall-mounted thermostat with on/off button and manual 3-position speed controller. Suitable for heating, cooling and ventilation. For 1 unit or for several units, combined with relay contacts. 12.8 CODE 8762.0000 2.9 € 247,20 CODE 8770.121 8770.125 8770.115 8770.116 type 02 - 03 04 - 06 08 10 € 85,70 93,65 118,30 129,90 CODE 8775.0021 8775.0025 8775.0015 8775.0016 type 02 - 03 04 - 06 08 10 € 27,40 38,00 48,40 55,65 Feet for model BRIW - BRBW Includes protective cover. Additional electric element options are fitted when fan convector and options are ordered together. With built-in options, delivery time will be longer. Includes security thermostat. Do not combine with 2nd heat exchanger B4. During the functioning of the electric element, air flow has to be guaranteed. electric connection 230 V - 1 f - 50 hz. Surcharge CODE 8721.6012 8721.6014 8721.6015 8721.6016 322 | type 02 - 03 04 - 06 08 10 Nominal power € Watts 1000 2000 2000 2000 237,40 261,30 353,10 560,70 jaga Top Performers CODE 8767.141 8767.123 type 02 - 03 - 04 - 06 08 - 10 € 85,70 85,70 € EX - 29/08/12 OPTIONS Fan-seal panel for model BRIC For visible mounting. Seal panel in the same colour as the radiator. Plenum with 2 connections ø16 cm for model BRBC exhaust plenum for connection of two air channels. Maximum length of the channel 2 metre, without loss of air flow. A CODE 8771.121 8771.125 8771.115 8771.116 type 02 - 03 04 - 06 08 10 € 57,55 57,55 63,65 73,20 Transformation to exhaust downwards for model BRIC Includes fan-seal panel for BrIc. Maximum height of ceiling: 2.6 m. Maximum fitting height: 2.3 m. only available when ordering with the appliance 31 CODE 8764.0221 8764.0225 8764.0215 8764.0216 type 02 - 03 04 - 06 08 10 A 26.7 40.6 54.2 67.9 € 558,10 558,10 637,00 747,70 Plenum with connection ø31.5 cm for model BRBC exhaust plenum for connection of one air channel . Maximum length of the channel 2 metre, without loss of air flow. 31 260 230 CODE 8774.0025 8774.0015 8774.0016 type 04 - 06 08 10 € 422,90 422,90 422,90 CODE 8764.0121 8764.0125 8764.0115 8764.0116 type 02 - 03 04 - 06 08 10 € 374,70 411,00 538,00 678,40 Air mixing box wall mounted model Air mixing box ceiling-mounted model 1. Servo motor 2. Air mixing box 3. Air inlet grille 1. Air mixing box 2. corner piece with adjustable air exhausting grille 3. Fan-seal panel 4. Adjustable air inlet grille For detailed information and prices of the parts see: www.theradiatorfactory.com L 1 2 3 2 € EX - 29/08/12 3 4 1 jaga Top Performers | 323 Jaga International - Verbindingslaan z/n - B-3590 Diepenbeek T: +32 11 29 41 16 - F: +32 11 29 41 60 - [email protected] your partner: 290812 - JAGA N.V.