Water meter JS 1,5 17 - Capital Investment Sp. z oo
Transkrypt
Water meter JS 1,5 17 - Capital Investment Sp. z oo
® Single-jet water meters METRON JS 1,5÷2,5 for cold (up to 50°C) or hot (up to 90°C)water measurement designed for remote read-out systems Description of operation Versions Type approvals, certificates ISO 9001 ISO 14001 Single-jet water meter Metron JS is designed for measuring hot usable water. It may be installed either in horizontal (H) or vertical (V) position. The water meter impeller is driven by a single, compact water jet, and it is the only moving part submerged in water. Rotations of the impeller are transmitted via the frontal magnetic coupling, the massive plate to the totalizer. Dry, hermetic totalizer placed in separate module totalizes volume of measured water andshows it in digital form - convenient for reading by the collector. Sub-multiplies of cubic metres may be read at the totalizer, and it is provided with motion indicator to make possible automatization of adjustments and verification. Adjustment device is protected against tampering with seal. Due to special impeller bearing construction and use of materials resistant to corrosion and abrasion, high transmitter durability is obtained. Depending on version, the water meter is provided with transmission module with reed relay pulse transmitter to transmit the information on flowing water volume to external perypheral equipment, for example, to remote read-out systems. Constructional solution of water meters JS is protected with utility pattern No. 55729 issued by Urz¹d Patentowy RP (Patent Office of Polish Republic). • 15 ZW - for cold water, with non-removable transmission module • 17 - for cold water, with removable transmission module • 17 BN - for cold water, prepared for installation of transmission module during water meter installation • 15 CW- for hot water, with non-removable transmission module • 18 - for hot water, with removable transmission module • 18 BN - for cold water, prepared for installation of transmission module during water meter installation Depending on type / size: • G³ówny Urz¹d Miar (National Office of Measures) - Poland WATER MEASUREMENT INTEGRATED MEASUREMENT SYSTEMS ® Recommended application Features advantages For measurement of cold potable water and hot usable water systems in flats or buildings, with possibility to transmit the information on flowing water volume to remote read-out systems. • METRON JS 1,5 15 ZW or JS 1,5 15 CW or JS 1,5 17 or JS 1,5 18 - standard sensitivity, for installation in DN15 systems, ready for operation with peripheral remote read-out equipment. • METRON JS 1,5 17 BN or JS 1,5 18 BN - standard sensitivity, for installation in DN15 systems. Recommended for installation in locations, where implementation of remote read-out system is planned in the future. • METRON JS 1,5 G1 17 BN - standard sensitivity, for installation in DN20 systems. Recommended for installation in locations, where implementation of remote read-out system is planned in the future. • METRON JS 2,5 15 ZW or JS 2,5 15 CW or JS 2,5 17- standard sensitivity, for installation in DN20 systems, ready for operation with peripheral remote readout equipment. • METRON JS 2,5 17 BN - standard sensitivity, for installation in DN20 systems. Recommended for installation in locations, where implementation of remote read-out system is planned in the future. • Metrology according to PN ISO 4064 • Metrological class B-H; A-V • For hot water meters - metrological specifications of water meters meet recommendations of OiML (Organisation De Metrologie) No. 72 for water meter type 1 o • Resistance to temperature increase up to o 50 C or 105 oC respectively • Correct operation at all climatic conditions • High sensitivity - registration of water leaks and slamm consumption • Easy installation and read-out • The use in remote read-out systems • Watertight, resistant to water condensation totalizer • Possibility to rotate the totalizer to facilitate read-out • O-ring type sealing • Protection against external magnetic fields • Increased rersistance to hard water, sand, etc. • Increased rersistance to water hammer in water system • two-year guarantee WATER MEASUREMENT INTEGRATED MEASUREMENT SYSTEMS ISO 9001 ISO 14001 ISO 9001 ISO 14001 zabudowa horizontal zabudowa vertical qt WATER MEASUREMENT INTEGRATED MEASUREMENT SYSTEMS mm mm mm mm H1 H2 H3 g Height Height Height Width mA V VA m Maximum voltage connected Maximum power connected Output cable length L/imp kg Maximum current connected Pulsing value Pulse transmitter parameters Weight mm cale L1 Water meter longth m3 Water meter connector thread d Zakres wskazañ Indication range bar m3 /h m3 /h 20 G 3/4 B 110 - 3,0 1,5 73 1,0 4 0,048 2,5 78 - 1,0 0,65 20 0,048 130 G1 B 0,70 79 74 G 3/4 B 99 999 0,00005 12 1 0,55 84 69 0,15 0,06 90 1 81 4 50 0,55 84 69 - 20 110 2,5 0,85 78 - 1 21 - 0,65 84 68 15 CW 1,0 0,048 12 4 2,5 0,85 78 - 81 90 01-00230 Terms and designations acc. to PN-ISO 4064: 1997 1,0 0,048 12 0,82 78,5 - 75 130 G1 B 0,25 0,10 0,25 0,05 0,2 5,0 2,5 20 17 BN 01-00231 JS 2,5 01-00235 17 2,5 0,24 01-00229 15 ZW 15 16 01-00167 18 BN 1,5 110 18 01-00168 12 4 0,70 0,65 2,5 79 - 74 20 78 73 110 15 CW 01-00110 0,24 01-00166 0,03 50 01-00160 JS 1,5 17 G1 BN m3 /h 0,24 01-00163 17 BN 0,12 m3 Dp pionowa [V][V] qmin installation 01-00109 17 m3 /h m3 /h m /h Wartoœæ Basic graduation dzia³ki value elementarnej Strata ciœnienia Pressure loss at q przy p qp Minimalnyvolumetric Minimum strumieñ objêtoœci flow rate Poœredni strumieñ Intermediate volumetric objêtoœci flow rate Minimalnyvolumetric Minimum strumieñ objêtoœci flow rate pozioma [H][H] qmin installation qs qt Poœredni strumieñ Intermediate volumetric objêtoœci flow rate qp Maksymalny Maximum volumetric strumieñflow objêtoœci rate C MAT o MAP Maksymalna Maximum working temperatura temperature robocza 3 bar Nominal diameter Œrednica nominalna Maksymalne Maximum working ciœnienie pressure robocze Nominalny Nominal volumetric strumieñflow objêtoœci rate mm N DN Wyró¿nik Water meter wodomierza distinguisher Nr katalogowy Catalogue No. 15 ZW Technical data Odmiana Version Typ i wielkoœæ Water meter typewodomierza and size ® ® Permissible limit error within the range qmin<q<qt 5% within the range qt<q<qs 2% within the range qt<q<qs 3% g Figure, curves cold water hot water d g Error [%] 1 0,8 5 3 0 -3 -5 0,6 0,4 0,2 0 Pressure loss [bar] d 0 Permissible adjustment range. Error and pressure loss curves Example of order Accessories Water meter METRON JS 1,5 17 designed for remote read-out, Joining elements, gaskets, nuts, extensions, traps, check valves, cut-off valves, etc. should be selected according to individual needs from our wide offer contained in our catalogues and specified as separate order positions. . METRON FABRYKA ZINTEGROWANYCH SYSTEMÓW OPOMIAROWANIA I ROZLICZEÑ Sp. z o.o. 87-100 Toruñ, ul. Targowa 12/22 tel. (056) 639 24 44, 639 24 01; fax (056) 639 26 99, 639 26 33 e-mail: [email protected] www.metron.torun.pl ISO 9001 ISO 14001 I_01_01 Note: The producer reserves the right for introducing changes in construction according to technical development.