sprzęt - Lucas Nülle
Transkrypt
sprzęt - Lucas Nülle
Table of Contents Table of Contents Technika pomiarowa i regulacji Applied Automatic Control Technology IAC 10/11 Lucas Nülle GmbH 1/5 1 2 2 2 www.lucas-nuelle.pl Technika pomiarowa i regulacji Applied Automatic Control Technology Applied Automatic Control Technology In the age of automation, closed-loop control technology is of supreme importance for modern, technical systems. Optimised control loops help engineers in the area of production and process control technology to efficiently manage such resources as energy and raw materials and ensure product quality. Furthermore, by integrating automatic technology, innovative, intelligent products can be made which are a prerequisite for being competitive on world markets. The spectrum of applications range from anti-locking systems in motor vehicles to auto-pilots in jumbo jets and position controls for satellites or space vehicles - from automatic range finding in pocket cameras to air-conditioning control in office buildings all the way to the automatic process control of chemical processing plants in the chemical industry. Using the training system for closed-loop control technology the student can obtain graphic and authentic training in the fundamentals and advanced topics of control engineering. This system utilises state-of-the-art training equipment like digital controllers and multimedia systems to provide all the technical know-how and hands-on skill the student requires. Lucas Nülle GmbH 2/5 www.lucas-nuelle.pl IAC 10/11 IAC 10/11 Closed-loop liquid level control/ flow-rate control "Closed-loop liquid level control" is a practice-oriented experiment set in applied control technology designed especially for didactic purposes. Due to immediate, visible nature of the controlled variable, i.e. "the level of the liquid", liquid level control is an extremely graphic experiment and is thus particularly well suited for an introduction into automatic control technology. The controlled system or liquid level basin is characterised by the fact that it has a medium response time. Thus experiments can be performed rapidly and the student can simultaneously monitor how the experiment is proceeding. The experiments focus on determining the most important parameters of controlled systems with compensation and the set-up and optimisation of control loops with continuous and discontinuous controllers. The liquid level basin has a plain form on which the foils can be attached to facilitate the marking of the liquid level as a function of time. The character of the controlled system can be modified by using various sliding partitions (delays of the 1st and 2nd order). 4 different outlet drains can be set on the filling basin and the inlet can be set as desired either using an ascending pipe or versus the filling pressure. Because of its modular design, the training system can, with the corresponding supplements, also be used for automatic flow-rate control and to explore measuring techniques. IAC 10 Automatic liquid-level control Set-up, putting into operation and optimising an automatic liquid-level control with variable controlled system characteristics Two-position controller in an integral-action controlled system of a higher order Two-position controller with delayed feedback in a closed-loop liquid level control system Two-position controller with float switch PI and PID controller in a closed-loop control system of the first and higher orders Automatic liquid level control with disturbance variable forward feed and precontrol IAC 11 Automatic flow-rate control Set-up, putting into operation and optimising an automatic flow-rate control with variable controlled system characteristics Operating principle, response and application of flow-rate measurement Investigating automatic flow-rate control with PI or PID controller and system response to disturbance and reference variable step changes Operating principle and use of step controllers and closed-loop flow-rate control with step controllers Wyposazenie podstawowe, w sklad którego wchodzi: Wyposażenie podstawowe, w skład którego wchodzi: Lucas Nülle GmbH 3/5 www.lucas-nuelle.pl Pos. nazwa produktu Bestell-Nr. Anz. 1 Obiekt regulacji regulatora poziomu napełnienia i przepływu, wraz ze zbiornikiem, zbiornikiem uzupełniającym, pompą i czujnikami CO3620-1H 1 2 Universal digital controller (DSP) CO3620-2A 1 Materialy szkoleniowe: Materiały szkoleniowe: Pos. nazwa produktu Bestell-Nr. 3 Podręcznik IAC 10/11 Regulacja poziomu napełnienia i przepływu za pomocą regulatora cyfrowego SH5003-6A Anz. 1 Zasilanie elektryczne: Pos. nazwa produktu Bestell-Nr. 4 Zasilacz prądu stałego (DC) 15 V/6 A stabilizowany CO3538-8A Anz. 1 Przyrzady pomiarowe: Przyrządy pomiarowe: Pos. nazwa produktu Bestell-Nr. 5 Cyfrowy miernik uniwersalny Multi 13S LM2330 Anz. 1 Akcesoria: Pos. nazwa produktu Bestell-Nr. Anz. 6 Bezpieczna złączka z wtykiem 4 mm czarna, 1000 V / 32 A CAT II SO5126-3R 20 7 Zestaw izolowanych przewodów pomiarowych 4 mm (30 szt.) SO5148-1A 1 Lucas Nülle GmbH 4/5 www.lucas-nuelle.pl 8 Mobilne stanowisko doświadczalne, wykonane z profili ST7200-3A aluminiowych, trzypiętrowe, cztery gniazda, 1250 x 700 x 1995 mm 1 9 Uchwyt PC do stanowiska doświadczalnego SybaPro, z regulacją wysokości i szerokości ST7200-5A 1 10 Uchwyt do płaskiego monitora ze składanym ramieniem, nośność do 15 kg, do zamocowania na profilu aluminiowym, VESA 75/100 ST8010-4T 1 11 Adapter do klawiatury jako rozszerzenie mocowania płaskiego monitora ST8010-4G 1 12 Ochronne etui na mobilne stanowisko doświadczalne – 3-piętrowe ST8010-9Y 1 Lucas Nülle GmbH 5/5 www.lucas-nuelle.pl