CHARACTERISTIC
FEATURES
The PNO-340/1000 type flame-proof voltage converter
with return to network is assigned for infinitely variable
control of rotational speed of the asynchronous motors
driving different mining machines. The converter is
equipped with active rectifier which enables a returning of the power to network. The converter is adjusted
to work in two control modes:
Local – using intrinsically safe control keyboard,
Remote – using the mining automatics by means of:
o Intrinsically safe contact inlets,
o Intrinsically safe frequency analog inlet,
o Intrinsically safe serial transmission,
o Intrinsically safe current loop standard transmission.
The main display enables the converter diagnostics
and informs about current working conditions and activation of protections. Basic working parameters during
operating are shown on the display. The converter is
adjusted to a team-work of several converters in the
Master-Slave system realizing the moments balancing
functions.
TECHNICAL DATA
Rated supply voltage
3 x 500 V or 3 x 1000 V AC (10%)
Supply voltage frequency
50, 60 Hz
Total rated current
340 A
Main outlet number
1 or 2
Maximum total power of connected motors
500 kW(1000V) or 340 kW(500V)
Over-current factor
1,5IN (60s)
Outlet voltage frequency
1 ÷ 100 Hz
Rated power of auxiliary outlet 42 V AC(230 V AC)
Max. number of auxiliary outlets (optional)
Control type
250 VA (2000 VA)
4
remote / local
Converter working mode
frequency / moment
Coolant
water
Enviromental Protection
IP 54
External Dimensions of housing
Width (without inlets)
Height
~ 2584mm
~ 933mm
Depth
~ 857mm
ANTI-EXPLOSION MARK
I M2 Ex d [ia ib] [op is] I
WE type testing certificate:
Zakład Chorzów
ul. Opolska 19
41- 500 Chorzów
Zakład Tychy
ul. Biskupa Burschego 3
43 - 100 Tychy
KDB 10ATEX047
www.kessa.com.pl
e-mail: [email protected]
Kopex Electric Systems S.A.
ul. Biskupa Burschego 3, 43 -100 Tychy
tel.: 00 48 32 249 94 80
fax: 00 48 32 241 34 57
serwis: 00 48 32 601 462 818