BT-A GB BT-A F BT-A D BT-A PL
Transkrypt
BT-A GB BT-A F BT-A D BT-A PL
GB BT-A F BT-A D BT-A PL MODES DESCRIPTION FONCTION et DESCRIPTION BETRIEBSARTEN - Electronic analogical thermostat specially designed to control different type of heating systems. - Thermostat électronique analogique spécialement conçu pour contrôler différentes installations de chauffage - Elektronisch-Analoges Thermostat für die Regelung verschiedener Arten von Heizungssystemen. - Modern design - design moderne - Modernes Design - Steuerung über internen Raumfühler. - Regulating on internal sensor. - Régulation sur sonde interne - Option: Possibility to regulate on external sensor (NTC 10K). The external sensor must be connected without power supply. At power up the thermostat automatically detects the sensor used. (If the external sensor is connected the regulation will use this sensor). - Régulation sur sonde externe en option (NTC 10K). Tout d’abord, connecter la sonde externe hors tension. A la mise sous tension le thermostat régulera sur celle-ci. OPIS TRYBÓW PRACY - Optional: Möglichkeit der Steuerung über externen Fühler (NTC 10K). Der externe Fühler muss im stromlosen Zustand angeschlossen werden. Bei Inbetriebnahme erkennt der Thermostat automatisch den angeschlossenen Fühler. (Bei Anschluss eines externen Fühlers erfolgt die Steuerung immer über diesen Fühler). STATUS-ANZEIGE Rouge fixe : Thermostat en chauffe (régulation sur sonde interne) Orange fixe : Thermostat en chauffe (régulation sur sonde externe) Rouge clignotant Flash de 0.5 seconde => Défaut sur sonde interne Flash de 1 seconde => Défaut sur sonde externe Rot: Heizung in Betrieb. Steuerung über internen Raumfühler. Orange: Heizung in Betrieb. Steuerung über externen Fühler. Leuchte blinkt rot 0,5 Sekunden Intervall => Störung des internen Fühlers 1 Sekunde Intervall => Störung des externen Fühlers Kolor czerwony: Regulacja ogrzewania z użyciem czujnika wewnętrznego. Kolor pomarańczowy: Regulacja ogrzewania z użyciem czujnika zewnętrznego. Czerwona dioda miga Cykl co 0,5 sekundy => awaria czujnika wewnętrznego Cykl co 1 sekundę => awaria czujnika zewnętrznego LED Leuchte Voyant d’état LED indicator - Nowoczesny wygląd - Regulacja w oparciu o wbudowany czujnik wewnętrzny. - Opcja: Możliwość regulacji w oparciu o czujnik zewnętrzny (10K NTC). Czujnik zewnętrzny należy podłączyć bez zasilania. Po włączeniu zasilania termostat automatycznie wykrywa używany czujnik. (Jeśli czujnik zewnętrzny jest podłączony regulator będzie używał tego czujnika). Einstellung Solltemperatur Température de confort Room setting - Elektroniczno- analogowy termostat przeznaczony do sterowania różnego rodzaju systemami grzewczymi. WSKAŹNIK LEDOWY VOYANT d’ETAT LED INDICATOR Red: Heating indication with internal sensor regulation. Orange: Heating indication with external sensor regulation Red blinking 0.5 second cycle => Internal sensor failure 1 second cycle => External sensor failure BT-A EIN / AUS Schalter Switch ON/OFF Switch ON/OFF CHARAKTERYSTYKA TECHNICZNA TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS Measured temperature precision Environmental: Operating temperature: Shipping and storage temperature: Setting temperature range Précision de mesure Environnent. (Températures) Fonctionnement: Transport et stockage : Plage de réglage de la température d’ambiance. Caractéristiques de régulation. Temps minimum de marche et d’arrêt. Protection électrique Alimentation Autonomie Type de sortie Regulation characteristics minimum time to start and stop Electrical Protection Power Supply Operating life Type of output Maximum Load Optional External sensor Norms and homologation: Your thermostat has been designed in conformity with the following standards or other normative documents: 0.1°C 0°C - 40°C -10°C to +50°C 5°C to 35°C by 0,5°C step Hysteresis 0.5°C 2 minutes ON and OFF (configurable) Class II - IP30 2 AAA LR03 1.5V Alkaline ~2 years 2 wires (free contact) Screw connectors <1.5mm². Up to 3A - 250Vac 50Hz 10k ohms at 25°C EN 60730-1 : 2003 EN 61000-6-1 : 2002 EN 61000-6-3 : 2004 EN 61000-4-2 : 2001 Low voltage 2006/95/CE EMC 2004/108/CE Maximum Load Sonde externe optionnelle Normes et homologation: Votre thermostat a été conçu pour répondre aux normes et directives européennes suivantes: TECHNISCHE DATEN 0.1°C 0°C - 40°C -10°C à +50°C 5°C à 35°C par palier de 0,5°C hystérésis de 0.5°C 2 minutes ON et OFF (configurable) Class II - IP30 2piles alkaline AAA LR03 1.5V ~2 ans 2 wires (free contact) Screw connectors <1.5mm². Up to 3A - 250Vac 50Hz 10k ohms à 25°C EN 60730-1 : 2003 EN 61000-6-1 : 2002 EN 61000-6-3 : 2004 EN 61000-4-2 : 2001 Basse tension 2006/95/CE CEM 2004/108/CE Genauigkeit der gemessenen Temperatur Umgebungsbedingungen: Betriebstemperatur: Transport- und Lagertemperatur: Einstellbereich Raumtemperatur Regelverhalten Minimum Start und Stop Zeit Schutzart Stromversorgung Ausgang Schaltleistung Optionaler externer Fühler Normen und Zulassungen: Ihr Thermostat hat in Übereinstimmung mit den folgenden Normen oder anderen normativen Dokumenten konzipiert: 0,1 °C Dokładnośc mierzonej temperatury +/- 0.1°C 0°C - 40°C -10°C bis +50°C Temperatura pracy: Temperatura przechowywania 0°C - 40°C -10°C to +50°C 5 - 35 °C Zakres regulacji temperatury Hysterese von 0,5 °C 2 Minuten EIN und AUS (einstellbar) Schutzklasse II - IP 30 Alkalibatterien LR03 1,5 V, Typ AAA (Micro) 2-Draht (free contact) Schraubklemmen <1.5mm². Max. 3A - 250Vac 50Hz NTC 10K bei 25°C EN 60730-1 : 2003 EN 61000-6-1 : 2002 EN 61000-6-3 : 2004 EN 61000-4-2 : 2001 Niederspannung 2006/95/CE EMC 2004/108/CE Charakterystyka regulacji Minimalny czas uruchomienia i wyłączenia Klasa obudowy Zasilanie Czas pracy Rodzaj wyjścia Maksymalne obciążenie Opcjonalnie czujnik zewnętrzny Normy I homologacje: Termostat został zaprojektowany zgodnie z następującymi normami lub innymi dokumentami normatywnymi: +5°C - + 35°C (rozdzielczość 0,5°C) Histereza 0.5°C 2 minuty ON i OFF (konfigurowalne) Klasa II - IP30 2 AAA LR03 1.5V Alkaiczne ~2 lata 2 przewodowe (bezpotencjałowe) złącza śrubowe <1.5mm². do 3A - 250Vac 50Hz 10k ohms( przy 25°C) EN 60730-1 : 2003 EN 61000-6-1 : 2002 EN 61000-6-3 : 2004 EN 61000-4-2 : 2001 Dyrektywy : LVD 2006/95/CE , EMC 2004/108/CE PPLIMP13042 Aa pl_BT_A_MuB_#9018800_P05609_BT-A_(GB-FR-DE-PL)_121119_ok..docx