optoCONTROL CLS-K - Micro

Transkrypt

optoCONTROL CLS-K - Micro
Instruction Manual
optoCONTROL CLS-K
CLS-K-10
CLS-K-11
CLS-K-20
CLS-K-30
CLS-K-31
CLS-K-40
CLS-K-50
CLS-K-51
CLS-K-60
CLS-K-61
CLS-K-63
CLS-K-65
Fiber optics sensors for gap, diameter, edge and presence monitoring
MICRO-EPSILON
Eltrotec GmbH
Heinkelstraße 2
73066 Uhingen / Germany
Tel. +49 (0) 7161 / 98872-300
Fax +49 (0) 7161 / 98872-303
e-mail [email protected]
www.micro-epsilon.com
Certified acc. to DIN EN ISO 9001: 2008
Contents
1.Safety......................................................................................................................................... 5
1.1
Symbols Used.................................................................................................................................................. 5
1.2Warnings........................................................................................................................................................... 5
1.3
Notes on CE Identification................................................................................................................................ 6
1.4
Proper Use........................................................................................................................................................ 7
1.5
Proper Environment.......................................................................................................................................... 8
2.
Functional Principle, Technical Data........................................................................................ 9
2.1
Short Description.............................................................................................................................................. 9
2.2
Measuring Principle.......................................................................................................................................... 9
2.3
Range / Scanning Range............................................................................................................................... 10
2.4Functions........................................................................................................................................................ 10
2.5
Technical Data................................................................................................................................................ 12
Models CLS-K-10 up to -51........................................................................................................... 12
2.5.1
Models CLS-K-60 up to -65........................................................................................................... 13
2.5.2
3.Delivery.................................................................................................................................... 15
3.1Unpacking....................................................................................................................................................... 15
3.2Storage........................................................................................................................................................... 15
4.Mounting.................................................................................................................................. 16
4.1
4.2
5.
5.1
5.2
Fiber Optics.................................................................................................................................................... 17
Mounting Fiber Optics and Power Supply..................................................................................................... 18
Electrical Connections ........................................................................................................... 20
Pin Assignment Model CLS-K-10 up to -51.................................................................................................... 20
5.1.1CLS-K-10........................................................................................................................................ 20
5.1.2
CLS-K-11 to -51............................................................................................................................. 20
5.1.3
CLS-K-10 /-11................................................................................................................................ 21
5.1.5
CLS-K-20 /-40................................................................................................................................ 21
5.1.7
CLS-K-30 /-50................................................................................................................................ 21
5.1.9
CLS-K-31 /-51................................................................................................................................ 21
Pin Assignment Models CLS-K-60 up to -65.................................................................................................. 22
optoCONTROL CLS-K
6.
Operation and Setting............................................................................................................. 23
7.
Instructions for Operation...................................................................................................... 33
6.1
Operation and Display Elements.................................................................................................................... 23
6.1.1
Models CLS-K-10 up to -51........................................................................................................... 23
6.1.2
Model CLS-K-61............................................................................................................................ 24
6.1.3
Models CLS-K-60 /-63 /-65............................................................................................................ 25
6.2Commissioning............................................................................................................................................... 26
6.2.1
Range Switching S1...................................................................................................................... 26
6.2.2
Adjustment of the Sensibility......................................................................................................... 27
6.2.2.1 Settings for Reflex Operation ...................................................................................... 27
6.2.2.2 Settings for Transmitted Light Mode............................................................................ 27
6.2.3
Additional Settings with Options................................................................................................... 28
6.2.4
Special Function for CLS-K-61...................................................................................................... 29
6.2.5
Special Function for CLS-K-63...................................................................................................... 31
6.2.5.1 Setting Reflex Operation / Transmitted Light Mode..................................................... 31
6.2.5.2Linearization................................................................................................................. 32
7.1Cleaning ......................................................................................................................................................... 33
8.Warranty .................................................................................................................................. 33
9.
Service, Repair ....................................................................................................................... 34
10.
Decommissioning, Disposal .................................................................................................. 34
Appendix
A 1
Optional Accessories.............................................................................................................. 35
A 2
Dimensions of the Fiber Optics Adapter................................................................................ 36
optoCONTROL CLS-K
Safety
1.
Safety
The handling of the system assumes knowledge of the instruction manual.
1.1
Symbols Used
The following symbols are used in the instruction manual.
Indicates a hazardous situation which, if not avoided, may result in minor or moderate
injuries.
NOTICE
Indicates a situation which, if not avoided, may lead to property damage.
Indicates a user action.
i
1.2
Indicates a user tip.
Warnings
Connect the power supply and the display / output device in accordance with the safety regulations for electrical equipment.
>> Danger of injury
>> Damage to or destruction of the sensor
The power supply must not exceed the specified limits.
>> Danger of injury
>> Damage to or destruction of the sensor
NOTICE
Avoid shock and vibration to the sensor.
>> Damage to or destruction of the sensor
Never kink the fiber optics and do not bend the fiber optics in small radii.
>> Damage to or destruction of the fiber optics, failure of the sensor
Protect the ends of the fiber optics against contamination (use protective caps).
>> Failure of the sensor
optoCONTROL CLS-K
Page 5
Safety
1.3
Notes on CE Identification
The following applies to the optoCONTROL CLS-K: EMC regulation 2004/108/EC
Products which carry the CE mark satisfy the requirements of the EMC regulation 2004/108/EC ‘Electromagnetic Compatibility’ and the European standards (EN) listed therein. The EC declaration of conformity is kept
available according to EC regulation, article 10 by the authorities responsible at
MICRO-EPSILON Eltrotec GmbH
Heinkelstraße 2
73066 Uhingen / Germany
The sensor is designed for use in industrial and residential areas and satisfies the requirements of the standards
-- EN 61000-6-3: 2011-09
-- EN 61000-6-2: 2006-03
-- EN 61000-4-2: 2009-12
-- EN 61000-4-3: 2011-04
-- EN 61000-4-4: 2013-04
-- EN 61000-4-5: 2007-06
-- EN 61000-4-6: 2009-12
-- EN 61000-4-11: 2005-2
-- EN 55011: 2011-04
The system satisfies the requirements if they comply with the regulations described in the instruction manual
for installation and operation.
optoCONTROL CLS-K
Page 6
Safety
1.4
Proper Use
The optical fiber amplifier series CLS-K are optical sensors. These are used with the additional use of fiber
optics for optical and non-contact recording of a diameter, edge, gap and the presence of a part during
-- measuring and inspection tasks
-- position detection of small parts
-- position and mounting control on assembly machines and feeding systems
-- presence monitoring
-- length and diameter control
The system may only be operated within the limits specified in the technical data, see Chap. 2.5.
Use the system in such a way that in case of malfunctions or failure personnel or machinery are not endangered.
Take additional precautions for safety and damage prevention for safety-related applications.
optoCONTROL CLS-K
Page 7
Safety
1.5
-------
Proper Environment
Protection class:
IP 65
Operating temperature:0 ... 50 °C (+32 ... +122 °F)
Storage temperature: -25 ... 70 °C (-13 ... +158 °F)
Humidity: 5 - 95 % (non-condensing)
Ambient pressure: Atmospheric pressure
EMC:Acc. to 1 EN 61000-6-3: 2011-09
EN 61000-6-2: 2006-03
EN 61000-4-2: 2009-12
EN 61000-4-3: 2011-04
EN 61000-4-4: 2013-04
EN 61000-4-5: 2007-06
EN 61000-4-6: 2009-12
EN 61000-4-11: 2005-2
EN 55011: 2011-04
1) In addition, it applies to all models:
When used in environments where there are particularly strong high frequency influences, it can come to deviations of the indicated accuracy tolerances.
optoCONTROL CLS-K
Page 8
Functional Principle, Technical Data
2.
Functional Principle, Technical Data
2.1
Short Description
The optoCONTROL series CLS-K offers a sensor solution, with which the sensor and the probes are coupled
by fiber optics and thus arranged separately.
Therefore these optical micrometers are applicable with adverse surrounding conditions like high temperatures, small mounting dimensions and bad accessibility in the plants.
The sensor consists of a compact transmission and reception unit for infrared light with an integrated signal
processing.
The transmission of the light to the target and back takes place by means of a high-quality fiber optics, which
works according to the principle of total reflection.
2.2
Measuring Principle
The sensor as measuring and testing amplifier with a double-armed fiber optics in the transmitted light mode
for intensity measurement, edge measurements and web edge controls with a resolution from > 0.1 mm and
a measuring frequency up to 4 kHz.
Transmitter cone
Transmitter
Quasi parallel transmitting beam
Receiver
Fig. 1 Measuring principle optoCONTROL CLS-K
optoCONTROL CLS-K
Page 9
Functional Principle, Technical Data
2.3
Range / Scanning Range
One Way 3
Fiber strand
Range
Minimum target size
ø mm
mm (type) 1
(type)
0.6
90
≤ 0.05
1.0
200
≤ 0.1
1.5
500
≤ 0.1
2.5
1700
≤ 0.2
3.0
2000
≤ 0.3
2.4
Sensor 3
Fiber strand
Scanning range
ø mm
mm (type) 1 2
0.6
≤ 10
1.0
≤ 30
1,5
≤ 80
2.5
≤ 165
3.0
≤ 180
Functions
The sensor optoCONTROL CLS-K supports following functions:
-- Precise and reliable detection of targets
-- Low drift by transmitter monitoring, thereby particularly suitable for measurement tasks.
-- High switching frequency and short response time
-- Sensor monitoring possible via analog signal
-- Scanning distance up to 200 mm 4
-- Range up to 2 m 4
-- Switching output: NPN, PNP, optocoupler, relays (depending on the model, see Chap. 2.5.1, see Chap.
2.5.2)
-- Drop-out delay 5 - 100 ms adjustable (optional)
-- Stable long-term behavior by controlling the transmitter diode emission
-- Large selection of fiber optics available, see Chap. A 1
The amplifiers CLS-K-61/-63 offer the possibility of spreading a signal range particularly important for the
solution of application on the entire analog range.
1) With 90° angular sensor mechanism reduced range
2) Related on Kodak white 90 %
3) See catalog optoCONTROL CLS-K
4) Depending on the fiber strand diameter
optoCONTROL CLS-K
Page 10
Functional Principle, Technical Data
5 V/10 mA
10 V/20 mA
Offset
α
α'
0 V/0 mA
Analog output
Switch S2 in position »1«
α = Pitch
0 V/mA
Analog output
Switch S2 in position »2«
Fig. 2 Functions optoCONTROL CLS-K-61 /-63
optoCONTROL CLS-K
Page 11
Functional Principle, Technical Data
2.5
Technical Data
2.5.1
Models CLS-K-10 up to -51
Model CLS-KOperating voltage VDC
Residual ripple
Current consumption
Switching delay
Response time
Switching frequency
Temperature drift
Reproducibility
Switching state
Operating mode
Sensitivity
Range switching S1
Hysteresis
Protection class
Operating temperature
Storage temperature
Housing material
Weight, dimensions
Switching output
Switching voltage
10
10 - 30
11
10 - 30
Light and dark
switch output
20
24
30
31
40
10 - 30
10 - 30
24
≤ 10 %
~ 50 mA
≤ 500 ms
≤ 120 μs
≤ 4 kHz
≤ (-)0.5 % /K
≤ 1 % at ∆ϑ = 2 K
LED display red and green
50
10 - 30
51
10 - 30
Light/dark switching switchable
Adjustable with 10-turn potentiometer P1
1:100 (Short range : Long range)
4 % of the measuring value range
IP 65 (with mounted fiber optics)
0 up to +50 °C (+32 ... +122 °F)
-25 °C up to +70 °C (-13 ... +158 °F)
Macrolon 8030/UL94V1, transparent cover, blue lower part
approx. 215 g / 135 g, 125 x 42 x 45 mm
Relays 1x Optocou- PNP 1 Relays 1x Optocou- PNP 1
Transistor 1
pler 1
pler 1
2x NPN O.C.
changechangeover
over
contact
contact
30 VDC
0.01-250 30 VDC 30 VDC 0.01-250 30 VDC 30 VDC
VAC 0.01VAC 0.01220 VDC
220 VDC
1) Short-circuit proof
optoCONTROL CLS-K
Page 12
Functional Principle, Technical Data
Model CLS-KSwitching current
10
11
20
50 μA 2A
5 μW 60 W
125 VA
30
5100 mA
31
5100 mA
40
50 μA 2A
5 μW 60 W
125 VA
50
5100 mA
51
5100 mA
4 kHz
4 kHz
60 Hz
4 kHz
4 kHz
60 Hz
4 kHz
4 kHz
≤ 2.0 V
≤ 2.0 V
≤ 2.0 V
≤ 2.0 V
5100 mA
Switching power
Switching frequency
max.
Saturation voltage
Pulse stretching
5 - 100 ms
Analog output
Type of connection
Electromagnetic
compatibility (EMC)
2.5.2
Models CLS-K-60 up to -65
Model CLS-KPower supply
Residual ripple
Current consumption
Switching delay
Switching frequency
Response time
Temperature drift
Reproducibility
Hysteresis
Analog output
Current output
Switching output
optoCONTROL CLS-K
≤ 2.0 V ≤ 2.0 V
Adjustable with potentiometer
P2
0.1 - 5 VDC, output resistance 1 kOhm
Line 2 m
Screw connectors 1.5 mm2 (plug-in version on request)
EN 61000-6-3: 2011-09, EN 61000-6-2: 2006-03, EN 61000-4-2: 2009-12, EN
61000-4-3: 2011-04, EN 61000-4-4: 2013-04, EN 61000-4-5: 2007-06, EN 61000-46: 2009-12, EN 61000-4-11: 2005-2, EN 55011: 2011-04
60
0 - 20 mA
61
63
12 - 30 VDC
≤ 10 %
~ 70 mA
≤ 500 ms
≤ 4 kHz
≤ 120 µs
≤ (-)0.5 % /K
≤ 1% at ∆ϑ = 2 K
4 % of the measuring value range
0 - 10 VDC
0 - 20 mA
Load ≤ 600 Ω
Transistor 2 x NPN O.C.
65
4 - 20 mA
Page 13
Functional Principle, Technical Data
Model CLS-KSwitching voltage
Switching current
Sensitivity
Range switching S1
Switching state
Operating mode
Protection class
Power supply and output
Operating temperature
Storage temperature
Type of connection
Housing material
Weight
Electromagnetic compatibility
(EMC)
optoCONTROL CLS-K
60
61
63
65
30 VDC
5 - 100 mA
Adjustable via 10-level potentiometer P1
1:100 (Short range : Long range)
LED display red/green
Light/dark switching output
IP 65 (with fiber optics)
Transient-protection polarity,
and short-circuit proof
0 up to 50 °C (+32 ... +122 °F)
-25 °C up to 70 °C (-13 ... +158 °F)
Screw connectors
Line 2 m
Screw connectors
Macrolon 8030 / UL94V1
approximately 215 g / 135 g
EN 61000-6-3: 2011-09, EN 61000-6-2: 2006-03, EN 61000-4-2: 2009-12,
EN 61000-4-3: 2011-04, EN 61000-4-4: 2013-04, EN 61000-4-5: 2007-06,
EN 61000-4-6: 2009-12, EN 61000-4-11: 2005-2, EN 55011: 2011-04
Page 14
Delivery
3.
Delivery
3.1
Unpacking
1 Sensor (amplifier) optoCONTROL CLS-K
1 Power supply cable 1
1 Instruction manual
Optional accessories, e.g. fiber optics, see Chap. A 1.
Check the delivery for completeness and shipping damage immediately after unpacking.
In case of damage or missing parts, please contact the supplier.
3.2
Storage
Storage temperature: -25 up to +70 °C
Humidity:
5 - 95 % (non-condensing)
1) The models CLS-K-11, -20, -30, -31, -40, -50, -51, -60, -63, -65 are delivered with screw connectors, see
Chap. 2.5. The models CLS-K-10 and CLS-K-61 are delivered with power supply cable.
optoCONTROL CLS-K
Page 15
Mounting
4.
NOTICE
Mounting
No sharped edged or heavy articles may affect on the cables. In any case, avoid definitely kinking of the
cables.
>> Damage or destruction of the cable, failure of the sensor
7 (.28)
88 (3.46)
60 (2.36)
31 (1.22)
30 (1.18)
42 (1.65)
14
(.55)
Connection Height: 45 mm Bore hole for mounting
fiber optics (1.77)
(for M5 screw)
PG 13.5
Fig. 3 Dimensional drawing of optoCONTROL CLS-K, dimensions in mm, not to scale
optoCONTROL CLS-K
Page 16
Mounting
4.1
Fiber Optics
Various fiber optics are available for the optoCONTROL CLS-K, siehe Kap. A 1. It is possible to use an optimal
probe even in confined conditions.
The fiber optics is inserted into the provided adapter and locked with the cap nut, see Chap. 4.2.
i
NOTICE
The male connector of fiber optics is coded on the amplifier side and must not be plugged in by force!
Treat the fiber optics carefully. Do not fall below the bending radius of the fiber optics (3 x the outside diameter).
>> Breakage of the fiber optics fibers
>> Impairment of the switching behaviors
Do not touch the front surface of the probe.
>> Impairment of functionality by contamination
Do not install more fiber optics probes directly next to each other.
>> Mutual interference
Do not use cable ties in order to fasten the PVC coating.
>> Breakage of the fiber optics fibers
optoCONTROL CLS-K
Page 17
Mounting
4.2
Mounting Fiber Optics and Power Supply
Fig. 4 Connection
fiber optics
i
Fig. 5 Model optoCONTROL CLS-K-10 with removed
cover
Fig. 6 Connection power
supply
Remove the cover of the amplifier, see Fig. 5 and install the amplifier in accordance with the provided
mounting holes on the housing.
Connect the amplifier in accordance to the pin assignment 1, see Chap. 5.1, see Chap. 5.1.
Mount the fiber optics to the amplifier, see Fig. 4 and lock it with the cap nut, see Fig. 7.
Attach the probe or the probes of the fiber optics in the required position to the target.
Consider here background reflections!
1) The models CLS-K-11, -20, -30, -31, -40, -50, -51, -60, -63, -65 are supplied with screw terminals, see Chap.
2.5. The models CLS-K-10 and CLS-K-61 are delivered with power supply cable.
optoCONTROL CLS-K
Page 18
Mounting
Power supply cable
Amplifier
Fiber optics
Cap nut
Fig. 7 Assembly of the fiber optics on the amplifier
Switch on the power supply.
After switching on the power supply, the green LED or the red LED lights.
optoCONTROL CLS-K
Page 19
Electrical Connections
5.
Electrical Connections
5.1
Pin Assignment Model CLS-K-10 up to -51
5.1.1
CLS-K-10
Pin assignment 1
brown
GND
pink
+24 VDC
green
Analog output +
yellow
Analog output GND
gray
NPN switching output 2
white
NPN switching output
Fig. 8 Power supply cable, open ends
3
Fig. 9 Pin assignment model CLS-K-10
5.1.2
CLS-K-11 to -51
1) No terminal block available
NPN O.C.
CLS-K-20/-40
Relay
CLS-K-30/-50
Optocoupler O.C. / O.E.
CLS-K-31/-51
PNP
1 2 3 4 5 6 7
2) Dark switching
3) Light switching
GND
+24 VDC
Analog
output
CLS-K-11
Switching
output
Terminal block
All models light/dark switching
Fig. 10 Pin assignment models CLS-K-11 to -51
The analog output, terminal block 3 and 4 (signal depends on the amount of light 0.1 - 5 V) is particularly
suitable for optimization of the probe position, for self-monitoring of the control path as well as for measuring,
inspection or monitoring applications. Furthermore, this output allows the function reserve.
The minimum voltage difference for reliable switching is ≥ 0.2 V (factory setting 1.6 - 1.8 V).
optoCONTROL CLS-K
Page 20
Electrical Connections
5.1.3
CLS-K-10 /-11
Connection type
NPN O.C
5.1.5
0V
0V
active dark switching
active light switching
5
6
7
+
Close
Open
5
6
7
GND
+ voltage to be switched e.g. 24 VDC
for control/consumer load to ground or PIN 5
CLS-K-31 /-51
Connection type
PNP output
optoCONTROL CLS-K
Gray
White
CLS-K-30 /-50
Connection type
Optocoupler output
Example: PNP
5.1.9
+ 24 VDC
CLS-K-20 /-40
Connection type
relays
5.1.7
Pink
7
Active + 24 VDC
Page 21
Electrical Connections
5.2
Pin Assignment Models CLS-K-60 up to -65
CLS-K-60/-63/-65
1
2
3
4
5
6
CLS-K-61 3
GND
12 - 30 VDC
Current output
1
NPN output O.C.
NPN output O.C. 2
brown
pink
green
yellow
gray
white
GND
12 - 30 VDC
Analog output +
Analog output GND
NPN output O.C. 1
NPN output O.C. 2
Fig. 11 Pin assignment models CLS-K-60 up to -65
1) Dark switching
2) Light switching
3) No terminal block available
optoCONTROL CLS-K
Page 22
Operation and Setting
6.
Operation and Setting
6.1
Operation and Display Elements
6.1.1
Models CLS-K-10 up to -51
Fig. 12 View on operating and display elements models CLS-K-10 up to -51
S2 Switch for light/dark changeover 1 P2 Potentiometer for timer 1
LED green LED red
S1 Range switching
P1 Potentiometer sensitivity
Fig. 13 Operating and display elements models CLS-K-10 up to -51
1) Not available with all versions
optoCONTROL CLS-K
Page 23
Operation and Setting
6.1.2
Model CLS-K-61
Fig. 14 View on operating and display elements model CLS-K-61
P3 OFFSET
zero offset
P2 Additional amplification
(Signal spreading)
1 2
Display
S2
Selector switch analog output
1 Basic function 0.1 - 5 VDC
2 Output 0 - 10 VDC
LED green
LED red
P1 Potentiometer sensitivity
S1 Range switching
Fig. 15 Operating and display elements model CLS-K-61
optoCONTROL CLS-K
Page 24
Operation and Setting
6.1.3
Models CLS-K-60 /-63 /-65
Measuring point GND
Measuring point U
Fig. 16 View on operating and display elements models CLS-K-60 /-63/ -65
P3 OFFSET
zero offset 1
P2 Additional amplification 1
(signal spreading)
Measuring point GND
Measuring point U
12
LED green
S2
Selecting switch analog output 1
1 = Basic function
0 - 10 mA (63)
2 = Output
0 - 20 mA (63)
LED red
S1 Range switching
P1 Potentiometer sensitivity
Fig. 17 Operating and display elements models CLS-K-60 /-63/ -65
1) Not available with version CLS-K-60/-65
optoCONTROL CLS-K
Page 25
Operation and Setting
P1 potentiometer 1
S1 range switch
Far
LED
Near
Fig. 18 Settings of the potentiometer P1 and range switch S1
6.2
Commissioning
After the assembly, set the range switch S1 on
Near, see Fig. 18.
The warm-up time of the amplifier is approximately 10 min.
6.2.1
Range Switching S1
Near
Far
In the case of overregulation of the amplifier (analog signal > 5 V), the sensitivity can be
reduced by the Near setting.
In the case of a too small scanning range /range an increase can be achieved by the Far
setting.
Shift the range switch S1 into the reverse position, if no Near or Far setting can be effected with the
sensitivity potentiometer.
Please use a different fiber optics or change the position of the fiber optics, if even with this measure
setting is not possible.
1) P1 = Potentiometer sensitivity
optoCONTROL CLS-K
Page 26
Operation and Setting
6.2.2
Adjustment of the Sensibility
6.2.2.1 Settings for Reflex Operation
Turn the potentiometer P1 (sensitivity) clockwise, until the LED changes from green to red (max.
15 turns), see Fig. 18.
Add one turn for the function reserve.
In the case of a large scanning range set S1 switch to
Far.
i
The analog signal can be used for finding the optimal setting.
6.2.2.2 Settings for Transmitted Light Mode
Adjust the range analogously in the case of adjusted and free light path, see Chap. 6.2.2.1.
Analog output
Light quantity on the receiver
Fig. 19 Settings for transmitted light mode
optoCONTROL CLS-K
Page 27
Operation and Setting
6.2.3
Additional Settings with Options
-- Light or dark switching is selectable with switch S2, see Fig. 20.
-- Pulse stretching is selectable with the potentiometer P2 by turning clockwise, see Fig. 20.
Switch S2
= light
Potentiometer P2
= dark
Fig. 20 Potentiometer P2 and switch S2
optoCONTROL CLS-K
Page 28
Operation and Setting
6.2.4
Special Function for CLS-K-61
The amplifier CLS-K-61 has the following additional special functions:
-- Zero offset
-- Signal spreading / Signal amplification
The amplifier offers the possibility to spread the signal range which is of special interest for the application to
the analog range.
P3 OFFSET
zero offset
P2 Additional amplification
(Signal spreading)
1 2
Display
S2
Selector switch analog output
1 Basic function 0.1 - 5 VDC
2 Output 0 - 10 VDC
LED green
LED red
P1 Potentiometer sensitivity
S1 Range switching
Fig. 21 Operating and display elements model CLS-K-61 / Special functions
optoCONTROL CLS-K
Page 29
Operation and Setting
1
Turn the potentiometer P1 (sensitivity) clockwise, until the LED changes from green to red (max.
15 turns), see Fig. 18.
Add one turn for the function reserve.
In the case of a large scanning range set S1 switch to
i
2
Far.
The analog signal can be used for finding the optimal setting.
Set the requested lower point onto the characteristic line to 0 V using the potentiometer P3.
The value can be reduced by a maximum of 3 V.
3
Set the requested upper point onto the characteristic line to 10 V using the potentiometer P2.
There is a maximum of a quadrupling of the original voltage possible.
4
Repeat process 1 and 2 to optimize the setting.
Back to factory setting:
Push the switch S2 in position 1.
Set the potentiometer P1 to the left (max. 10 turns).
Push the switch S2 in position 2.
Set voltage with potentiometer P3 to 0 V.
Push the switch S2 in position 1.
Set analog voltage with potentiometer P1 to 5 V.
Push the switch S2 in position 2.
Set voltage with potentiometer P2 to 10 V.
optoCONTROL CLS-K
Page 30
Operation and Setting
6.2.5
Special Function for CLS-K-63
6.2.5.1
Setting Reflex Operation / Transmitted Light Mode
You will find the description in detail, see Chap. 6.2.2.1, see Chap. 6.2.2.2.
1
Turn potentiometer P1 (sensitivity) clockwise until the LED changes from green to red (Max.
15 turns).
2
In the case of a large scanning range S1 set to
3
Adjust the range analogously in the case of adjusted and free light path, see Chap. 6.2.2.1.
P3 OFFSET
zero offset
Far.
P2 Additional amplification
(signal spreading)
Measuring point GND
Measuring point U
12
LED green
S2
Selecting switch analog output
1 = Basic function
0 - 10 mA (63)
2 = Output
0 - 20 mA (63)
LED red
S1 Range switching
P1 Potentiometer sensitivity
Fig. 22 Operating and display elements model CLS-K-63 / special functions
optoCONTROL CLS-K
Page 31
Operation and Setting
6.2.5.2
Linearization
1 Based on the basic function the linear part of the function is prepared with P3 “zero point“ and P2
“steepness“.
2 This adjustment requires repetitions as the settings of the potentiometer interfere each other.
3 A multimeter 0 – 10 VDC is connected to the measuring points “GND” and “U”, see Fig. 16, see Fig. 17
(S2: “2“; 10 V = 20 mA) for the adjustment procedure.
4 Start value for zero point approximately – 2 V.
optoCONTROL CLS-K
Page 32
Instructions for Operation
7.
Instructions for Operation
7.1
Cleaning
We recommend cleaning the front surface of the probe regularly.
Dry cleaning
You can use an anti-static brush for lenses, or blow down the front surface using dehumidified, clean, oil-free
compressed air.
Wet cleaning
Use a clean, soft, lint-free cloth or a lens cleaning tissue and pure alcohol (isopropanol) to clean front surface.
Never use commercial glass cleaners or other cleaning agents.
8.
Warranty
All components of the device have been checked and tested for perfect function in the factory. In the unlikely
event that errors should occur despite our thorough quality control, this should be reported immediately to
MICRO-EPSILON Eltrotec.
The warranty period lasts 12 months following the day of shipment. Defective parts, except wear parts, will be
repaired or replaced free of charge within this period if you return the device free of cost to MICRO-EPSILON
Eltrotec. This warranty does not apply to damage resulting from abuse of the equipment and devices, from
forceful handling or installation of the devices or from repair or modifications performed by third parties.
No other claims, except as warranted, are accepted. The terms of the purchasing contract apply in full. MICRO-EPSILON Eltrotec will specifically not be responsible for eventual consequential damages. MICRO-EPSILON Eltrotec always strives to supply the customers with the finest and most advanced equipment. Development and refinement is therefore performed continuously and the right to design changes without prior
notice is accordingly reserved. For translations in other languages, the data and statements in the German
language operation manual are to be taken as authoritative.
optoCONTROL CLS-K
Page 33
Service, Repair
9.
Service, Repair
In the event of a defect on the amplifier or fiber
optics please send us the effected parts for repair
or exchange.
In the case of faults the cause of which is not clearly identifiable, the whole measuring system must be
sent back to:
10.
MICRO-EPSILON Eltrotec GmbH
Heinkelstraße 2
73066 Uhingen / Germany
Tel: +49 (0) 7161 / 98872-300
Fax: +49 (0) 7161 / 98872-303
[email protected]
www.micro-epsilon.com
Decommissioning, Disposal
Disconnect the power supply cable and the fiber optics from the amplifier.
The colorCONTROL CLS-K is produced according to the directive 2011/65/EU, “RoHS“.
Do the disposal according to the legal regulations (see directive 2002/96/EC).
optoCONTROL CLS-K
Page 34
Appendix | Optional Accessories
Appendix
A 1
Optional Accessories
Designation
Foto
Description
Article number
Reflex fiber optics
10810351
Transmitted fiber
optics
10810490
Different fiber optics see catalog optoCONTROL CLS-K.
Example:
FART-A2.0-2.5-1200-67°
FADM-A2.0-2.5-1200-67°
optoCONTROL CLS-K
Seite 35
Appendix | Dimensions of the Fiber Optics Adapter
A 2
34 (1.34)
Ø15
(.59 dia.)
Ø 3.8
(.15 dia.)
8
(.31)
Dimensions of the Fiber Optics Adapter
15
(.59)
optoCONTROL CLS-K
Cap nut
M18x1
Seite 36
MICRO-EPSILON Eltrotec GmbH
Heinkelstr. 2 · 73066 Uhingen / Germany
Tel. +49 (0) 7161 / 98872-300 · Fax +49 (0) 7161 / 98872-303
[email protected] · www.micro-epsilon.com
X9751308-A011074HDR
*X9751308-A01*

Podobne dokumenty