OIL IMMERSED TRANSFORMERS TRANSFORMATORY OLEJOWE

Transkrypt

OIL IMMERSED TRANSFORMERS TRANSFORMATORY OLEJOWE
TRANSFORMATORY OLEJOWE
OIL IMMERSED TRANSFORMERS
POL
ENG
Informacje Ogólne
General features
1DV]HWUDQVIRUPDWRU\ROHMRZHVąMHGQ\PL]SLHUZV]\FKSURGXNWyZ
ILUP\7UDIR (OHWWUR 6ą GRVWĊSQH ] NRQVHUZDWRUHP RUD] Z ZHUVML
KHUPHW\F]QHM
Our oil immersed transformers are among TRAFO ELETTRO’s first
products and they are available with conservator, and also and in
hermetically sealed version.
1D Ī\F]HQLH NOLHQWD PRJą ]RVWDü Z\SRVDĪRQH Z VSHFMDOQH
XU]ąG]HQLDNRQWUROQR]DEH]SLHF]DMąFH
On the customer’s request, they can be equipped with special control and
safety devices.
3URGXNXMHP\WUDQVIRUPDWRU\ROHMRZHR]DNUHVLHPRF\RGN9$
GR09$LNODVLHL]RODFMLGRN9
Our range of oil immersed transformers with mineral oil or synthetic oil is
from 50 kVA to 30 MVA with voltages up to 145 kV.
=DVWRVRZDQLD
Applications
7UDQVIRUPDWRU\ ROHMRZH PRJą E\ü LQVWDORZDQH ]DUyZQR
ZHZQąWU] EXG\QNyZ MDN L QD ]HZQąWU] ZLĊF Vą RGSRZLHGQLH
GODNDĪGHJRURG]DMXDSOLNDFML
7UDQVIRUPDWRU\ ] ROHMDPL QLHSDOQ\PL PRJą E\ü VWRVRZDQH
Z PLHMVFDFK ]DJURĪRQ\FK SRĪDUHP 3R]D W\P WUDQVIRUPDWRU\
ROHMRZH PRJą E\ü LQVWDORZDQH Z PLHMVFDFK R GXĪ\P
]DQLHF]\V]F]HQLXG]LĊNL]DVWRVRZDQLX]HZQĊWU]Q\FKREXGyZ
RGSRUQ\FKQDZSá\Z\NDĪGHJRĞURGRZLVND
-HVWHĞP\ZVWDQLHVSHáQLüZV]\VWNLHZ\PDJDQLDNOLHQWyZFRGR
NRORUXLW\SXREXGRZ\QSREXGRZ\F\QNRZHLPHWDOL]RZDQH
Oil immersed transformers can be installed indoor or outdoor, so they
are suitable for every type of application.
They can be also installed in areas where there is fire risk, just
using not flammable oils. Besides, oil immersed transformers can
be installed in high polluted areas, since opportunely treated with
external coating adapted for any type of atmospheric pollution.
We are also able to respect customer specifications for painting and
coatings (i.e. zinc coating and metallization). Such characteristics are
normally
6SRVyESURGXNFML
Manufacturing features
5G]HĔPDJQHW\F]Q\
5G]HQLHPDJQHW\F]QHZ\NRQ\ZDQHVą]QLVNRVWUDWQ\FKEODFK]
]LDUQHP]RULHQWRZDQ\PZL]RODFMLNDUOLWRZHMáąF]RQ\FKPHWRGą
VNRĞQąOXEPHWRGą6WHS/DSFRSR]ZDODQD]PQLHMV]HQLHVWUDW
MDáRZ\FK L REQLĪHQLH SR]LRPX KDáDVX -HVW RQ QDVWĊSQLH
XPLHV]F]DQ\ Z VWDORZ\FK MDU]PDFK L SRNU\ZDQ\ Z Z\VRNLHM
WHPSHUDWXU]H ODNLHUHP RFKURQQ\P Z FHOX ]DSHZQLHQLD
Z\VRNLHMZ\WU]\PDáRĞFLLVWDELOQRĞFLSRGF]DVSU]HPLHV]F]DQLD
MDN UyZQLHĪ RGSRUQRĞFL QD QDSUĊĪHQLD SRZVWDMąFH SU]\
]ZDUFLDFK
8]ZRMHQLD'ROQHJR1DSLĊFLD
8]ZRMHQLD GROQHJR QDSLĊFLD VNáDGDMą VLĊ ] IROLL DOXPLQLRZHM
OXE PLHG]LDQHM L]RORZDQHM PDWHULDáHP R RGSRZLHGQLHM NODVLH
Z\WU]\PDáRĞFL WHUPLF]QHM L V]F]HJyOQHM FKDUDNWHU\VW\FH
FR VSUDZLD ĪH MHVW RQR Z VWDQLH Z\WU]\PDü QDSUĊĪHQLD
G\QDPLF]QH Z\VWĊSXMąFH SU]\ ]ZDUFLX =DFLVNL GROQHJR
QDSLĊFLD Vą Z\NRQDQH ] DOXPLQLRZ\FK OXE PLHG]LDQ\FK
SUĊWyZ SRSU]H] DXWRPDW\F]QH VSDZDQLH 3U]\ GXĪ\FK
SUąGDFKVWRVRZDQHVąSU]HZRG\ZLHORĪ\áRZHRGRGDWNRZHM
L]RODFMLHSRNV\GRZHMPLĊG]\Ī\áDPL3R]ZDODWRQDX]\VNDQLH
GRVNRQDá\FK ZáDĞFLZRĞFL PHFKDQLF]Q\FK L ]QDF]Qą UHGXNFMĊ
VWUDWZ\ZRáDQ\FKSUąGDPLZLURZ\PL
Magnetic core
The magnetic core is manufactured with grain-oriented low-losses
laminations, insulated with Carlyte, mitred type or step-lap, in order to
reduce the sound level and the no-load losses as much as possible.
It is clamped by steel yokes and treated with protective varnish coating
at high temperature, in order to guarantee high sturdiness to the shortcircuit stresses and during the movement.
Low voltage windings
The L.V. windings are produced by electrolytic aluminium or copper
foils, insulated with adequate thermal class material, with the particular
characteristic that makes the winding protected and resistant to the
high short-circuit forces. The exit terminals are made with aluminium
or copper bars through automatic welding.
For high current is used a transposed conductors-cable with epoxy
that combines an excellent mechanic resistance to the reduction of
the losses caused by eddy currents.
6SRVyESURGXNFML
Manufacturing features
8]ZRMHQLD*yUQHJR1DSLĊFLD
8]ZRMHQLDJyUQHJRQDSLĊFLDZ\NRQDQHMHVW]HPDOLRZDQ\FK
SU]HZRGyZ PLHG]LDQ\FK OXE WDĞP PLHG]LDQ\FK Z L]RODFML
SDSLHURZHM 6WDQGDUGRZR X]ZRMHQLH JyUQHJR QDSLĊFLD MHVW
QDZLMDQHEH]SRĞUHGQLRQDGX]ZRMHQLHPGROQHJRQDSLĊFLD
']LĊNLWHPXFDáHX]ZRMHQLHPD]ZDUWąLPRFQąNRQVWUXNFMĊ
RGSRUQąQDVLá\HOHNWURG\QDPLF]QHSRZVWDMąFHSRGF]DV]ZDUü
'OD QDSLĊü SRZ\ĪHM N9 X]ZRMHQLH MHVW Z\NRQ\ZDQH ]
SU]HSODWDQ\FKF\OLQGU\F]Q\FKG\VNyZ=DSHZQLDWRZLĊNV]ą
Z\WU]\PDáRĞü QD SU]HSLĊFLD XGDURZH 8]ZRMHQLD PRJą E\ü
Z\NRQDQH ] URĪQHJR URG]DMX SU]HZRGQLNyZ =D NDĪG\P
UD]HPEDGDVLĊNWyU\EĊG]LHQDMRGSRZLHGQLHMV]\GRGDQHJR
UR]ZLą]DQLD
3RNU\ZDL]ELRUQLNROHMRZ\
3RNU\ZD MHVW SU]\NUĊFRQD GR ]ELRUQLND XV]F]HOQLHQLH MHVW
JZDUDQWRZDQHSU]H]RGSRZLHGQLHXV]F]HONLJXPRZHOXE]PDWHULDáX
VSLHNDQHJR=ELRUQLNLGODPDá\FKWUDQVIRUPDWRUyZVąZ\NRQ\ZDQH
] IDOLVWHM EODFK\ WDN DE\ ]DSHZQLü GRGDWNRZą SU]HVWU]HĔ SU]\
UR]V]HU]DQLX WHUPLF]Q\P ROHMX L UR]SUDV]DQLD JHQHURZDQHJR
FLHSáD ĝUHGQLH L GXĪH WUDQVIRUPDWRU\ Vą SURGXNRZDQH ]
UDGLDWRUDPL NWyUH PRĪQD SU]\áąF]\ü EH]SRĞUHGQLR GR ĞFLDQ\
]ELRUQLND OXE UDGLDWRUDPL ] ]DZRUDPL GR SU]HFKZ\W\ZDQLD ROHMX
Z FKáRGQLF\ :V]\VWNLH ]ELRUQLNL Vą GRNáDGQLH WHVWRZDQH SRGF]DV
ID]\EXGRZ\LQDSHáQLDQLDZFHOX]DSHZQLHQLDRGSRUQRĞFLREXGRZ\
QD F\NO ]PĊF]HQLRZ\ UR]V]HU]DQLH VLĊ L NXUF]HQLH Z\QLNDMąF\ ]
WHUPLF]QHMUR]V]HU]DOQRĞFLROHMX
High Voltage windings
H.V. windings are manufactured with electrolytic copper enamelled
wire or strip insulated with pure cellulose paper. Normally is wound
directly above the L.V. winding. Thereby the resulting winding is really
compact and strong in order to withstand the eventual short circuit
electrodynamics forces.
For voltages higher than 72,5 kV the winding is manufactured with
interleaved disc in order to optimize the distribution of the steep-front
over voltages.
The windings can be realized with many types of conductors and
windings that are studied every time to identify the most suitable one.
Tank and cover
The cover is bolted to the tank, the sealing is guaranteed by a suitable
rubber gasket or sintered material. The tank for small transformers is
realized by undulated sheet in order to allows the oil expansion and
the dispersion of the heat generated by the transformer, whereas on
medium / big transformers it is manufactured with radiators that can
be directly connected to the tank wall or with valve for intercepting the
oil inside the radiator. All tanks are carefully tested during construction
phases and with filled transformer in order to guarantee the body
resistance to fatigue cycles (expansion and shrinkage) deriving from
the thermal dilation of the oil.
6SRVyESURGXNFML
Manufacturing features
Olej
2OHML]RODF\MQ\]DZDUW\ZWUDQVIRUPDWRUDFKWRPDWHULDáGLHOHNWU\F]Q\
ZROQ\RG3&%RF]\V]F]RQ\LRVXV]RQ\
1DSHáQLDQLHRGE\ZDVLĊPHWRGąSUyĪQLRZą
1DĪ\F]HQLHNOLHQWDPRĪOLZHMHVW]DVWRVRZDQLHROHMyZVLOLNRQRZ\FK
DOER V\QWHW\F]Q\FK QD ED]LH HVWUyZ W\SX 0,'(/ 3á\Q\ WH
JZDUDQWXMą ZLĊNV]H EH]SLHF]HĔVWZR Z SU]\SDGNX ]DJURĪHQLD
SRĪDURZHJRSRQLHZDĪSRVLDGDMąZ\ĪV]ąWHPSHUDWXUĊ]DSáRQX
3RNU\FLHSRZLHU]FKQLLPDORZDQLH
:V]\VWNLH F]ĊĞFL ZHZQĊWU]QH Vą SLDVNRZDQH L PDORZDQH
SURGXNWDPL QLHUR]SXV]F]DOQ\PL Z JRUąF\P ROHMX =HZQĊWU]QH
ĞFLDQ\]ELRUQLNDLSRNU\Z\VąSLDVNRZDQHRUD]SRNU\ZDQHVHULą
MHGQRZDUVWZRZ\FK SRZáRN ODNLHUQLF]\FK GREUDQ\FK WDN E\
Z\WU]\PDá\HNVWUHPDOQHZDUXQNLĞURGRZLVNRZHDMHGQRF]HĞQLH
QLHVWDQRZLá\]DJURĪHQLDGODĞURGRZLVND
Insulating oil
The insulating oil contained in the transformer is dielectric mineral
type PCB free, preventively treated and dried. The filling is done
under-vacuum.
it is possible to request also transfomers filled with silicon oil or
synthetic ester based of MIDEL type. Those fluids ensure a greater
safety in case of fire because of their higher flammability point.
Painting and surface treatment
All internal parts are sandblasted and painted with products insoluble
to hot oil. The outside walls of the tank and cover are sandblasted
and processed with a series of single-layer water-soluble paint
coating, suitable to withstand extreme environmental conditions butd
respecting the environment.
Mocne strony
Strengths
áDWZRğýPRQWDīX
Easy to install
:\VRNDRGSRUQRğýQD]ZDUFLDG]LċNL]DVWRVRZDQLXVSHFMDOQHML]RODFMLZ\NRQDQHM]SUHV]SDQXQDFLQDQHJRSLâDPLGLDPHQWRZ\PL
High resistance of short circuits forces thanks to the application of diamond dotted insulation paper on the windings
2GSRZLHGQLRUR]PLHV]F]RQHDNFHVRULDGRXSURV]F]HQLDF]\QQRğFLNRQVHUZDF\MQ\FKEH]GRGDWNRZHJRZ\SRVDīHQLD
Suitably positioned accessories to simplify the maintenance operations without additional equipment
$NFHVRULDSUDZLGâRZRRNDEORZDQH]HVSHFMDOQĆRVâRQĆLQXPHUDPLLGHQW\ILNDF\MQ\PLGODâDWZHMLQVWDODFMLLNRQVHUZDFML
Accessories properly wired with special sheathing and with identification numbers for an easy installation and maintenance
3RNU\WHVSHFMDOQĆSU]\MD]QĆğURGRZLVNXIDUEĆ
Special painting with eco-friendly products
:\PDJDQDNRQVHUZDFMDZRNUHVLHXī\WNRZDQLDMHVWPLQLPDOQDLSURVWD
The required maintenance over time is minimal and simple
www.stargraphic.it
TRANSFORMATORY OLEJOWE
OIL IMMERSED TRANSFORMERS
Via G.Galilei, 5 - 36071 Tezze d´Arzignano (VI) - Italy
TEL.+39 0444 482204 - FAX.+39 0444 483956 - E-mail: [email protected]