Technical Documentation
Transkrypt
Technical Documentation
ZN1CL ‐ IRSC CHARACTERISTICS KNX Bus Coupling unit integrated. Complete data saving. CE Directives OK. IRSC Technical Documentation IRSC Plus: To Control Split A/C units. See “Correspondence Table” IRSC Open: IR codes recording to later reproduce them. A/V devices. A/V devices (IRSC Open Application Program) SOFTWARE FOR ZN1CL-IRSC Reduced size: 45 x 45 x 14 mm. Suitable to be placed into deep flush –mounting box Device management through IR codes. º Split units (IRSC Plus Application Program) 1. KNX Bus Connector 2. LED 3. Programming Button 4. Air Connector 5. IR emitter 6. Base connector DIMENSIONS & DESCRIPTION. Prog: To set the device programming mode. By keeping this button pressed while powering the BUS, the “Secure mode” is set. Led: Led “On” indicates programming mode active. Led blinking every 0.5s, the device is set in “secure mode”. IR emitter: Infrared flasher diode to send commands to the split. 2 1 3 6 5 4 ESPECIFICACIONES GENERALES Concept Control device for Voltage Voltage margin KNX Supply Max Power Consumption Max Current Connection type External Supply Operation temperature Storage temperature Ambient humidity (relative) Storage humidity (relative) Complementary Characteristics Safety Class Operation Type Type of protection Assembly Min clearances Response to BUS voltage failure Response to BUS failure recovery Operation indicator Accessories PCB CTi index Enclosure Weight © Zennio Avance y Tecnología S.L. Edition 9 Description Home & Building Automation 29V DC 20…31V DC 278mW 9,6mA Bus connector TP1, section 0,50 mm² Not needed 0ºC a +55ºC -20ºC a +70ºC 30 a 85% RH (No condensation) 30 a 85% RH (No condensation) Class B Class II Continuous operation IP20, Clean environment Recommended in deep flush-mounted box (60mmx60mm) Not needed Complete data saving Data recovery and IR commands sending as programmed Led ON when programming button is pressed IR wired flasher diode with protective capsule 175 V PC+ABS, FR Aprox. 60 gr. For further info www.zennio.com Page 1 de 2 ZN1CL ‐ IRSC IRSC Technical Documentation CONNECTION DIAGRAM. Connection diagram example: Consumer electronic device with IR receiver (IRSC Open Application Program) IRSC Open IR Receiver device IR commands must be loaded into the device. A specific tool “IRSC Open Capture” downloadable into the a Z38i (ZN1VI-Z38i) is available for this purpose For further info, please read the IRSC Open user manual. Connection diagram example: A/C Split (IRSC Plus Application Program) IRSC Plus IR commands are already preloaded into the device. It will only be necessary to identify the IR remote controller in the “Correspondence Table” provided by Zennio to later set the correct identifier in the ETS parameterization environment. For further info, please read the IRSC Plus user manual. IR EMITTER SPECIFICATIONS Connection method Aerial connector Installation Stick the IR emitter onto the unit IR receiver Cable section Cable length Peak wave length (λp) Radiated emission power (Φe) Radiated intensity Emission response time 0,15 mm² 2,15 m 940 nm 2,4 mW 2,4 mW/sr Parameter option. Min recommended 2 s. SAFETY INSTRUCTIONS. Do not connect the Main Voltage (230 V) or any other external voltages to any point of the BUS. Connecting an external voltage might put all the KNX system into risk Ensure there is enough insulation between the AC Voltage cables and the BUS ones. A minimal clearance of 4 mm must be ensured The IR emitter must be stuck onto the air conditioning receiver. The protective capsule must not be removed. © Zennio Avance y Tecnología S.L. Edition 9 For further info www.zennio.com Page 2 de 2