DINA-TempLine - PF electronic
Transkrypt
DINA-TempLine - PF electronic
DINA-TempLine DINA-TempLine: Cascadable temperature controller with temperature limiter The cascadable temperature controller system consists of a cascade module, controller module, control panel and a field bus gateway. A temperature limiter (ATEX module) can be added. The gateway enables a communication between the temperature controller system and a host diagnostic system. DNTRCM Controller DNTKM DNTAM DNTBE Cascade module ATEX module Control panel DNTL-TD Configuration software Controller module type DNTRCM The controller modules and the cascade modules will be connected via a bus of a 35mm DIN rail. The power supply results via the cascade module. The connection from the controller to the control panel will be done via RJ45 plug socket. To measure the temperature four PT100 sensors can be connected. Alternative thermo elements are possible. Every controller has 4 digital outputs. An analogue output (4-20mA) to drive a power controller is available. 2-point- or PID-controller is available for the temperature regulation. The controller can be used to monitor a minimum temperature (anti-freeze protection). A stand alone function is also possible. The controller module is placed in a 45mm housing. It can be mounted to a 35mm DIN rail. Cascade module type DNTKM The cascade modules provide the electrical connection between the temperature controller lines. 16 temperature controllers can be connected to one cascade module. In the whole installation there are 250 controllers modules possible. The number of the cascade modules is optional. The cross linking between the cascade modules will be done via RJ45 plug socket. Diagnostic communication results between controller lines and cascade modules. Four semi conductor outputs enable error messages. The outputs can be optionally configured. The cascade module is placed in a 22,5mm housing. It can be mounted to a 35mm DIN rail. ATEX limiter module type DNTAM The ATEX limiter works autarkic and can be used with a PT100 sensor. The output contacts open and remain open, if the temperature limit is exceeded. To reset the contacts the temperature limit has to be under-running and a quit button at the module has to be activated. An unidirectional interface enables a data communication with the controller about the set value, actual value and status information. The data can be displayed via the control panel or via the configuration software. The module is placed in a 22,5mm housing. It can be mounted to a 35mm DIN rail. Control panel type DNTBE The control panel provides the configuration of all controller modules. Set value, actual value and the status of the system can be displayed via the 7-segment display and a lot of various LED. The control panel is provided to be mounted in a control board. DNTL-TD Product information version 01 15.04.2009 page 1 of 2 DINA-TempLine The configuration software enables an easy programming and a online diagnostic of the controllers via a computer. Type Features DNTRCM Controller module with 4 control loops 4 inputs for 4 temperature sensors 1 current input for set-temperature 1 current input to measure the plant current 4 contact outputs 1 current output (4-20mA) to control the plant heater 1 current output (4-20mA) for actual-temperature 2 alarm outputs positive switching 1 communication interface to ATEX-module 1 communication interface via the DIN rail to the gateway DNTKM Cascade module 4 outputs positive switching 1 communication interface via the DIN rail and RJ45 female connector to the gateway DNTAM ATEX module 1 input for temperature sensor 1 safe contact output 1 communication interface to the controller DNTBE Control panel for the configuration of the controller Display for actual- and set-temperature Display for the selected control loop All products are supplying with 24V DC. Plan of installation 8/ATX 5 6 7 8 21 22 23 24 5 6 7 8 21 22 23 24 BUS IN FE1 FK1F1FE3 FK3 F3FE2FK2 F2- ATX FE4 FK4 F4- Fuse K1 K2 K3 K4 ELEKTRONIK BUS IN Pwr DI BUS OUT Pwr FE1 FK1 F1FE3 FK3 F3FE2 FK2 F2- ATX FE4 FK4 F4- Fuse K1 K2 K3 K4 Pwr DI DI ELEKTRONIK ELEKTRONIK DNTRCM DNTRCM Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 DNTKM AL1 AL2 AL3 AL4 Iin Iout AL1 AL2 13 14 23 24 Tin Tin- ToutTout- 33 34 43 44 9 10 11 12 25 26 27 28 9 10 11 12 25 26 27 28 13 14 15 16 13 14 15 16 29 30 31 32 13 14 15 16 29 30 31 32 Cascade 1 2 3 4 Controller modules 1 2 3 4 17 18 19 20 1 2 3 4 17 18 19 20 5 6 7 8 21 22 23 24 5 6 7 8 21 22 23 24 1 2 3 4 1 2 3 4 5 6 7 8 A1 A1 A2 A2 24V DC 0V Pwr 17 18 19 20 1 2 3 4 17 18 19 20 1 2 3 4 21 22 23 24 5 6 7 8 21 22 23 24 5 6 7 8 FE1 FK1F1FE3 FK3 F3FE2 FK2 F2- ATX FE4FK4 F4- Fuse K1 K2 K3 K4 Pwr DI ELEKTRONIK FE1 FK1 F1FE3 FK3 F3FE2 FK2 F2- ATX FE4 FK4 F4- Fuse FE FK F- ATX A1 A1 A2 A2 24V DC 0V FE FK F- K1 K2 K3 K4 Pwr BUS IN 17 18 19 20 BUS IN 1 2 3 4 BUS IN 17 18 19 20 BUS OUT A1 A1 A2 A2 0V Gateway 24V DC 1 2 3 4 BUS IN 1 2 3 4 DI DI DNTRCM DNTRCM Pwr OK Tripped Reset ELEKTRONIK ELEKTRONIK DI ELEKTRONIK Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 DNTKM AL1 AL2 AL3 AL4 Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 9 10 11 12 25 26 27 28 9 10 11 12 25 26 27 28 13 14 15 16 13 14 15 16 29 30 31 32 13 14 15 16 29 30 31 32 Cascade 1 2 3 4 Controller modules DNTAM 13 13 14 14 13 14 15 16 ATEX-module 1 2 3 4 17 18 19 20 1 2 3 4 17 18 19 20 5 6 7 8 21 22 23 24 5 6 7 8 21 22 23 24 Control panel DINA-TempLine CH1 CH2 CH3 CH4 LIM AL1 AL2 SP DNTKM AL1 AL2 AL3 AL4 13 14 15 16 ELEKTRONIK ELEKTRONIK DNTRCM DNTRCM Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 9 10 11 12 25 26 27 28 9 10 11 12 25 26 27 28 13 14 15 16 29 30 31 32 13 14 15 16 29 30 31 32 Product information version 01 CH MIN MAX I< FUSE SENSOR BUS IN Pwr FE1 FK1 F1FE3 FK3 F3FE2 FK2 F2- ATX FE4 FK4 F4- Fuse K1 K2 K3 K4 Pwr DI ELEKTRONIK DNTKM AL1 AL2 AL3 AL4 13 14 15 16 DI CH DI ELEKTRONIK ELEKTRONIK DNTRCM DNTRCM Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 K1 K2 K3 K4 Pwr BUS IN DI FE1 FK1F1FE3 FK3 F3FE2 FK2 F2- ATX FE4FK4 F4- Fuse BUS IN DI Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 K1 K2 K3 K4 Pwr A1 A1 A2 A2 24V DC 0V BUS OUT ELEKTRONIK BUS IN DI BUS OUT Pwr K1 K2 K3 K4 Pwr FE1 FK1 F1FE3 FK3 F3FE2 FK2 F2- ATX FE4FK4 F4- Fuse BUS IN FE1 FK1 F1FE3 FK3 F3FE2 FK2 F2- ATX FE4 FK4 F4- Fuse BUS IN A1 A1 A2 A2 24V DC 0V Iin Iout AL1 AL2 13 14 23 24 Tin Tin- Tout Tout- 33 34 43 44 Quit Reset 9 10 11 12 25 26 27 28 9 10 11 12 25 26 27 28 DI 13 14 15 16 29 30 31 32 13 14 15 16 29 30 31 32 DNTBE 15.04.2009 ELEKTRONIK page 2 of 2